pecifications of Cable Conductor H125
ACSR Conductor Cable
1.Conductor:Hard drawn aluminium wire
2.Steel core:Galvanized steel wire,solid or concentric stranded
ACSR Conductor, Aluminium Conductor Steel Reinforced of Cable Conductor H125
Aluminum Conductors Steel Reinforced ACSR ASTM B 232 of Cable Conductor H125
Area |
Stranding and wire diameter |
Approx. overall diameter |
Weight |
Nominal breaking load |
Nominal DC resistance at 20 deg. | ||||||
Nominal |
Alum. |
Steel |
Total |
Alum. |
Steel |
Alum. |
Steel |
Total | |||
AWGorMCM |
mm2 |
mm2 |
mm2 |
mm |
mm |
mm |
Kg/km |
Kg/km |
Kg/km |
kN |
Ohm/km |
1272 |
644.51 |
81.68 |
726.19 |
54/3.90 |
19/2.34 |
35.10 |
1795 |
638 |
2433 |
194.00 |
0.04516 |
1272 |
644.51 |
17.87 |
662.38 |
36/4.78 |
1/4.78 |
33.42 |
1777 |
140 |
1917 |
115.85 |
0.04472 |
1351.5 |
684.84 |
47.10 |
731.94 |
45/4.40 |
7/2.92 |
35.16 |
1898 |
368 |
2266 |
160.70 |
0.04230 |
1351.5 |
684.84 |
86.71 |
771.55 |
54/4.02 |
19/2.41 |
36.17 |
1906 |
679 |
2585 |
206.05 |
0.04250 |
1431 |
725.10 |
50.32 |
775.42 |
45/4.53 |
7/3.02 |
36.24 |
2009 |
393 |
2402 |
170.71 |
0.03994 |
1431 |
725.10 |
91.87 |
816.97 |
54/4.14 |
19/2.48 |
37.24 |
2019 |
719 |
2738 |
218.24 |
0.04013 |
1510.5 |
765.35 |
52.90 |
818.25 |
45/4.65 |
7/3.10 |
37.20 |
2120 |
414 |
2534 |
177.89 |
0.03784 |
1510.5 |
765.35 |
96.84 |
862.19 |
54/4.25 |
19/2.55 |
38.25 |
2131 |
759 |
2890 |
230.20 |
0.03802 |
1590 |
805.68 |
55.48 |
861.16 |
45/4.77 |
7/3.18 |
38.16 |
2232 |
435 |
2667 |
187.02 |
0.03595 |
1590 |
805.68 |
102.13 |
907.81 |
54/4.36 |
19/2.62 |
39.26 |
2243 |
799 |
3042 |
242.55 |
0.03613 |
80 |
40.52 |
14.13 |
54.65 |
8/2.54 |
1/4.24 |
9.32 |
112 |
110 |
222 |
23.60 |
0.7115 |
101.8 |
51.61 |
30.06 |
81.67 |
12/2.34 |
7/2.34 |
11.71 |
143 |
235 |
378 |
41.75 |
0.5613 |
110.8 |
56.13 |
32.77 |
88.90 |
12/2.44 |
7/2.44 |
12.22 |
156 |
256 |
412 |
51.25 |
0.5161 |
134.6 |
68.19 |
39.81 |
108.00 |
12/2.69 |
7/2.69 |
13.46 |
189 |
311 |
500 |
61.70 |
0.4248 |
159 |
80.58 |
46.97 |
127.55 |
12/2.92 |
7/2.92 |
14.63 |
223 |
367 |
590 |
72.55 |
0.3595 |
176.9 |
89.48 |
52.19 |
141.67 |
12/3.08 |
7/3.08 |
15.42 |
248 |
409 |
657 |
78.50 |
0.3237 |
190.8 |
96.71 |
56.39 |
153.10 |
12/3.20 |
7/3.20 |
16.03 |
268 |
441 |
709 |
84.80 |
0.2995 |
203.2 |
102.97 |
91.87 |
194.84 |
16/2.86 |
19/2.48 |
18.14 |
285 |
722 |
1007 |
128.80 |
0.2813 |
211.8 |
107.10 |
62.45 |
169.55 |
12/3.37 |
7/3.37 |
16.84 |
297 |
488 |
785 |
93.90 |
- Q: What brand of cable is good, what are the top ten brands of wires?
- Power circuit box, the home of the circuit is divided into lighting, walls, air conditioning, etc., there is the bathroom and the kitchen line and the separation of the room.
- Q: The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
- This situation generally have to extend the line triangle can link the ground, the two feet when you use the foot to feel the foot, and step on the bench as long as the non-conductive feel. No seriousness
- Q: What is the difference between wires and cables?
- The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
- Q: IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
- Wiring room refers to the distribution of the weak floor of the room, the weak point refers to the building weak vertical pipe
- Q: Wire and cable CCC product consistency is what
- Wire of course, is to use a good slightly, the first life, ah, can not buy cheap because of cheap, like China's top ten brands to buy the brand on the purchase of these brands I feel very good ah, Po Sheng , Luneng Taishan, Far East, Shenghua cable, on the up, prosperous photoelectric, Nexans Nexans these brands of wire is still very good. The landlord you can go to the above to learn more detailed information ah, the top ten wire brand is very detailed, the landlord can understand very clearly, the above brand is very good, my father last time to go above to see, and then buy
- Q: Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
- Wipe with water that day. You can also use ink thinner
- Q: IPhone6 This cable or accessories have not been certified how to solve
- Rubber over the bridge surface curing treatment, nice and at the same time to ensure a safe Pressure tonnage: 5 tons to 65 tons, indoor and outdoor are available (and provide only tramway) Uses: used in engineering department exhibition company, power company construction line, play a role in protecting the line Rubber trough ■ tough, insulated, high pressure (maximum load of 65 tons) rubber over the bridge ■ suitable for all outdoor weather, rain, lightning, moisture, flame retardant ■ surface non-slip surface texture ■ Position protection to the type of cable and communication data cable ■ unique design, no need to destroy the ground installation ■ durable, the surface of non-slip surface texture ■ simple installation, easy to move, structural design briefs practical ■ unique elbow, tee, Selection ■ 1 hole, 2 holes, 3 holes, 4 holes, 5 holes design, fully applicable to the exhibition, performing arts, workshops, power, communications, military and other industries 2 Specifications Table 1 Specifications 1000 × 130 × 20 aperture 40 × 13 Weight 12KG (for indoor cable signal line, etc) 2 Specifications 1000 × 275 × 40 aperture 105 × 30 Weight 32KG (for indoor wiring too thick if the wire, etc) 3 Specifications 1000 × 250 × 50 aperture 32 × 35 Weight 7KG (applicable Over motor vehicles and large trucks, etc) 4 Specifications 900 × 500 × 75 Aperture 50 × 60 Weight 19KG (for motor vehicles and forklifts, etc) 5 Specifications 900 × 500 × 75 Aperture 32 × 35 Weight 21KG (for the workshop workshop, such as truck ) 6 Specifications 900 × 620 × 110 Aperture 90 × 90 weight The amount of 28KG (for small trucks and large trucks, etc) 7 specifications 1000 × 310 × 55 aperture 35 × 35 weight 15KG (for workshop workshop forklift or private cars, etc) 8 specifications 770 × 485 × 65 aperture 40 × 40 weight 18KG For the workshop workshop plant forklift, etc)
- Q: Why this cable has not yet been certified
- The manufacture of wire and cable is completely different from that of most electromechanical products
- Q: How are various wire and cable models named?
- Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
- Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
- The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
1. Manufacturer Overview
Location | Anhui, China |
Year Established | 1998 |
Annual Output Value | USD516,971,041 |
Main Markets | Southeast Asia; Mid East; Domestic Market; |
Company Certifications | ISO9001:2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | shanghai |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 21-50 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 160,000 square meters |
No. of Production Lines | Above 20 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |
Send your message to us
Cable Conductor HS125
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5mt m.t.
- Supply Capability:
- 40000mts/year m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches