Lanco brand self priming centrifugal 4 inch sewage diesel water pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Products Introduction
Main datas:
Capacity( flow rate) : 15 ~ 145 m3/h
Head : 2~35 m
Speed:650 ~ 1950 rpm
Impeller diameter:247.65 mm
Pump weight: 260 kg /280 kg
Power:1 ~ 30 hp
Quotation
Cast iron pump body+ Ductile impeller+ NSK Bearing+Mechanical seal
FOB NINGBO 1400USD/PCS
Advantage :
Big pump body pass 76.2mmsolid ,high suction head 7.6 m
Convenient repair and clean (a person ten minutes)
Removable cover plate ,replaceable wear plate
OEM ,L/C ,TT ,O/A ,D/P,D/A and so on
CE ,TUV .ISO
NAME: P series 4 inch non clogging high suction self priming diesel water pump
Self Priming pump units are available for Solids Handling or Clear Liquid service.
Typical mounting configurations are Engine Driven for Skid or Trailer Mounted packages
and Frame Mounted Electric Driven. Pumps also are available in a variety of different metallurgies.
1) Main Character
1.Beautiful shape and fine structure,reliable performance.
2.With strong capacity of delf priming, no need to equip with flap valve.
3.Non-clog, and with powerful capacity of passing big solid..
4.The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.
5.The unique lubrication oil mechanical seal cavity makes the performance more reliable.
6.Special check valve structure can make the pump working quickly.
7. When working, the gas and liquid works together .
8. Low rotary speed,reliable operation,long time usage, easy to maintenance.
9.Advanced pressure protector make pump the pump work safe.
2) Application Area
1. Municipal project, sewage project, instruction project.
2.Uptown,hospital, hotel sewage transportation.
3.Classification of municipal sewage factory treatment and concentrate system engineering.
4. Factory and contaminated water delivery.
3) Industries Served
♦ Construction | ♦ Industrial | ♦ Municipal |
♦ Agricultural | ♦ Mining | ♦ Dewatering |
♦ Industrial Waste | ♦ Sewage | ♦ Oil Field |
♦ Petrochemical | ♦ Paper Mills | ♦ Processing |
4)Parameter
5) Mounting Configuration
♦ Frame Mounted
♦ Base Mounted Electric Driven
♦ Engine Driven SAE Mounted
♦ Engine Driven Skid or Trailer Packages
♦ Horizontal or Vertical V-Belt Driven
Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.
The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.
Or the condition of pump station would be provided.
♦FAQ:
1. Q: Can I know more about your products?
A: Pls view our website: www.lanco.cc.
2. Q: What’s your MAQ of this item?
A: 1~2PCS
3. Q: What is the lead time?
A: 10~30 days after receiving your payment,depends on pumps.
4. Q: where is your loading port?
A: Ningbo, China port
5. Q: Are you a manufacturer or trading company
A: We are a manufacturer specialize in water pump and other pumps more than 20 years.
For more information, please contact me.
- Q:Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
- The use of frequency converter to adjust the speed of the motor can also adjust the flow, the advantage is to save electricity.
- Q:Why does the centrifugal pump start and close first when the outlet valve is closed?
- The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
- Q:What are the parts of a pump? How do you classify it?I just want to know
- According to the working principle can be divided into: centrifugal type and volume type centrifugal pump. By the centrifugal force of the impeller will accelerate the refrigerant, through to stay, so as to achieve the purpose of boosting; volume by changing the refrigerant in the flow volume to boost purpose.According to the media and installation conditions, water pump: centrifugal pump used: the impeller pump shaft, a curved blade on the impeller impeller outlet. The central entrance water vertically along the tangential direction of axial flow pump: high speed, large flow, low lift, mixed flow pump and centrifugal pump structure similar to that of the blade outlet angle is different, wide flow channel, close to the performance of axial flow pump displacement pump: safety valve must be opened before the start (metering pump, screw pump)
- Q:Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
- Q:What are the ways of hydraulic pumps?
- There are several ways:Direct flow mode, such as external gear pump;Port plate, such as vane pump, axial piston pump, etc.;
- Q:Why should the pump be closed when the centrifugal pump is started?
- On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
- Q:What is the cause of the damage of pump bearings?
- In high-speed equipment, the most likely damage to bearings is high temperature.
- Q:What are the conditions required for hydraulic pumps to complete oil absorption and compression?
- 2, the change of working volume is periodic, and in each cycle, the oil absorption process is changed from small to big, and the process of oil pressure is changed from large to small;3, suction oil cavity must be separated from each other without interference.
- Q:How many kinds of pumps are available and the operating principles of various pumps?
- There are many kinds of pumps. There are different classifications according to different standards. If classified according to the principle of work, can be broadly divided into the following four categories:1, vane pumps: centrifugal pumps, axial pumps, mixed flow pumps, vortex pumps, etc.;2, displacement pumps: piston pumps, piston pumps, diaphragm pumps and so on;3, power rotary pump: screw pump, gear pump, etc.;4 、 special function: jet pump, water hammer pump, magnetic drive pump, etc.;
- Q:What's the difference between non negative pressure and variable frequency water pump?
- When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Lanco brand self priming centrifugal 4 inch sewage diesel water pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords