• Insulated Polyurethane Sandwich Panels System 1
  • Insulated Polyurethane Sandwich Panels System 2
  • Insulated Polyurethane Sandwich Panels System 3
  • Insulated Polyurethane Sandwich Panels System 4
  • Insulated Polyurethane Sandwich Panels System 5
Insulated Polyurethane Sandwich Panels

Insulated Polyurethane Sandwich Panels

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
3000 m²
Supply Capability:
100000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

Advantages of baikal wall panels: 
environment-protecting, 
easy installation, 
energy-saving, 
fire-proof,light-weight,etc.

 

 

Testing report of Physical performance
testing itemtechnical requirementtesting resulttesting method
thermal conductivity 
(core material/W(m*k)

≤0.040W(m*k)0.024GB/T 10297-1998
compressive strength,kpa≥30kpa52.7JG149-2003
water absorption,%≤424%415%JG149-2003
density of the panel
(three layers),kg/sqm
≥1.7*1001.821*100GB/T 6343-1995
bending resistance 
under 0.5KN,mm
≤18.313.3GB/T 9341-2000
cementation strength,Mpa>0.10.18JG149-2003
smog resistance(h)/no spot of erosion,
no color change
GB 5938-1986
weather resistance(h)/no damage on surface,color
changes on level 4-5
GB/T 17657-1999
oxygen index, %>2626.1GB/T 2046-1993
horizontal burning 
of PU
everage burning time
≤90s
77GB/T 8332-1987
everage burning area 
≤50mm
37GB/T 8332-1987
wind resistance 
data,Kpa
/8JG149-2003

 

 

Insulation performance comparison
testing itemsgypsum boardcommon outer wallsandwich panel
thermal conductivity0.50.150.018
the comparison of thickness27.8cm8.34cm1.0cm

 

Advantages:

 1.easy construction

 

 Construction is convenient, quick, labor saving, not only reduces the workers’ on site operation procedure and time but also reduces the comprehensive cost.For exterior wall renovation,  treatment of base is no longer needed,it can be directly fixed on the original wall. Its cost is less than any product of the same kind in current building material market.


Q: Air conditioning year after the addition of Calvary is not the reason for refrigeration
The system after spraying the rigid foam polyurethane insulation layer in the wall to form a continuous seamless overall, winter can avoid the heat bridge, greatly reduce the indoor heat loss; summer can greatly reduce the sun due to the external walls of the heat conduction, and then So that heating, air conditioning, energy consumption, energy saving effect is obvious, can reduce energy consumption, protect the theme structure, to extend the life of the building
Q: Similar to the color steel tile, floor board, the roof of the push is how much ah
5 cm, 10 cm, 15 cm and 25 cm The general material 5 cm price between 45 to 75 yuan; 75 cm price of 55 to 90 yuan range; 10 cm price of 70 to 100 yuan, Caigang Caigang purification plate thickness can also Custom So we must first understand their choice of materials and thickness, different scenes of the plate is not the same choice
Q: Can sandwich panels be used for noise barriers?
Yes, sandwich panels can be used for noise barriers. Sandwich panels are typically made of two outer layers of rigid materials, such as metal or wood, with a layer of insulating material in between. This insulating layer helps to absorb and dampen sound waves, making sandwich panels an effective choice for noise barriers. The insulating material in sandwich panels can be made of various materials, such as mineral wool or polyurethane foam, which have excellent sound absorption properties. These materials are designed to trap and dissipate sound energy, preventing it from passing through the barrier and reducing the noise levels on the other side. Sandwich panels for noise barriers can be customized to meet specific noise reduction requirements. Different thicknesses and densities of the insulating layer can be used to achieve the desired level of sound insulation. Additionally, the outer layers can be designed to be reflective or absorptive, depending on the desired acoustic performance and aesthetic preferences. Sandwich panels offer several advantages for noise barrier applications. They are lightweight, making them easy to install and transport. They also have a high strength-to-weight ratio, providing structural integrity to withstand environmental factors such as wind and vibrations. Furthermore, sandwich panels can be designed to be durable and resistant to corrosion, ensuring long-lasting performance in outdoor environments. In conclusion, sandwich panels are a suitable choice for noise barriers due to their sound absorption properties, customization options, and durability. They can effectively reduce noise levels and provide a quieter environment for various applications, such as highways, factories, residential areas, and commercial buildings.
Q: What is the quota of the demolition of the color steel plate?
Answer: safety production laws and regulations, including safety in production (BE) A
Q: What are the different types and uses of clean color steel plates?
Color steel sandwich panels: 1. Corrugated sandwich board may be in the fixed time when the nail is too tight lead to corrugated subsidence, the formation of small puddles, it will leak, the solution with mildew copper phosphate repair. 2. Flat sandwich plate may be due to the possibility of two plates of the gap between the edge of the gap is not enough height, the general rain is no problem, the amount of rain on the big leak, the solution is to increase the height of the edge fold (the cost of repair each gap about 15 yuan about). Also do not understand can ask!
Q: Are sandwich panels suitable for train stations?
Train stations can benefit from the use of sandwich panels, a construction material consisting of two outer layers and an insulating core. These panels offer excellent thermal insulation, fire resistance, and soundproofing properties, making them an ideal choice for train station applications. The insulation provided by sandwich panels helps to regulate the temperature inside the station, creating a comfortable environment for passengers and staff regardless of external weather conditions. This can result in reduced energy consumption and lower heating or cooling costs. Fire resistance is crucial in train stations, where the risk of fire is a major concern. Sandwich panels are highly fire-resistant, which can help contain and slow down the spread of fire. This provides valuable time for evacuation and firefighting efforts. Sandwich panels also offer excellent soundproofing capabilities, reducing noise transmission in train stations. This creates a more peaceful and comfortable atmosphere for passengers and staff. Furthermore, sandwich panels are lightweight, easy to install, and cost-effective. They can be customized to meet specific design requirements, allowing for flexibility in architectural design while still maintaining their functional benefits. In conclusion, sandwich panels are a suitable choice for train stations due to their thermal insulation, fire resistance, soundproofing properties, and ease of installation. Their use can enhance the overall comfort, safety, and efficiency of train stations, benefiting both passengers and staff.
Q: The general company to re-change the new version, the replacement is very troublesome. Our company's exterior wall decoration board convenient installation, thermal insulation, waterproof moisture, noise reduction noise are interested can consult. Polyurethane sandwich panels for the application of polyurethane sandwich panels
First of all, the tempered glass can no longer be drilled high and the ancient antecedant for the short hole, will certainly be broken, and do not make the edge of the local force, but also fragile (so use a few bumps to block it The method is not good) should be tempered glass as a whole embedded in a slot, you can in the low side of the welding of a corner, the length of the glass and the same edge, play a block of the role, in addition, usually the tempered glass is not easy to be deformed Damage, but can not make it too much force
Q: Can the foam sandwich be used as a cleaning plate?
In addition to the thickness, bending, corrosion does not meet the standard can not be used, there is no relevant specific provisions, buckle raft Gong Gong folder slander attack Wei Wei Shan pieces of steel pipe scaffolding is the advantage of re-use, easy disassembly, this problem a bit strange
Q: Sandwich board is the two sides are metal, the middle of the building materials is the problem of foam added: What is the use of more adhesive
Buy the quality of a little bit of what the material is no problem, although the price is more expensive, but the first safety is important
Q: What is the difference between rock wool sandwich panels, EPS sandwich panels and polyurethane sandwich panels?
When the top of the ventilation tube can not be extended out of the roof, the following ventilation can be used: ①, set the side wall ventilation tube ②, by setting the confluence of the ventilation pipe after the extension of the side wall to extend above the roof ③, set up self-circulation ventilation pipeline system , the following circumstances should be set up ventilation riser: ①, when the drainage pipe to take the sanitary equipment drainage design flow than in Table 449 only set the top of the drainage pipe drainage pipe maximum design drainage capacity ②, the building standards require a high multi-storey residential and public buildings, 10-storey and 10-storey high-rise building life drainage riser , the following drainage pipe should be set up annular ventilation pipe: ①, connecting four and more than four sanitary ware and the length of more than 12m of the drainage pipe ②, connecting 6 and 6 or more toilet toilet cross pipe ③, do not exceed the above provisions, but the nature of the building is important, the use of high requirements or set the device when the ventilation tube , the health, quiet requirements of the building, the living drainage pipe should be set to ventilator tube , the drainage pipe at all levels of the building shall be provided with an annular ventilation pipe, and shall be provided with a main ventilation riser or a secondary ventilation riser for the connection of the layers , ventilation riser shall not accept the equipment of sewage, waste water and rain; not connected with the duct and flue

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords