• Hot Sale End Suction Pump for Air Contioner System 1
  • Hot Sale End Suction Pump for Air Contioner System 2
  • Hot Sale End Suction Pump for Air Contioner System 3
Hot Sale End Suction Pump for Air Contioner

Hot Sale End Suction Pump for Air Contioner

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

End Suction Centrifugal Pump

1.Structure of Hot Sale End Suction Pump for Air Contioner Description

End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.

End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.

2.Main Features of Hot Sale End Suction Pump for Air Contioner

very easy to be installed and maintained

Back pull-out design

•Driven through flexible coupling

•Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3.Hot Sale End Suction Pump for Air Contioner Specification

 

Material

Cast iron

Pump diameter

350-1600mm

Flow range

1~200L/s

Pressure range

0.2~2.25MPa

Motor power range

1.5~200kW

Inlet/outlet Diameter

DN50~DN200mm

 

Casing

Cast Iron Standard, Ductile Iron, Stainless Steel Optional

Impeller

Bronze Standard ,Cast Iron, Stainless Steel Optional

Shaft

ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional

Shaft Seal

Mechnical Seal, Gland Pakcing Optional

 

Flow rate

2-1100m3/h

Head

2-152m

Speed

1450 or 2900(50hz),1750 or 3500(60hz)

Working Pressure

1.6PMa or 2.0PMa

 

4.Picture of Hot Sale End Suction Pump for Air Contioner

Hot Sale End Suction Pump for Air Contioner 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.

 

 

Q: What are the uses and precautions of magnetic pumps?
Notice of use:1. prevent particles from enteringHas the ferromagnetic impurities and particles into the magnetic actuator and bearing friction is not allowed.The transport of crystallization or precipitation of the medium to the flushing (after pumping water, poured into the pump cavity drained after running 1min), in order to ensure the service life of bearing.The transport medium containing solid particles, the pump flow tube inlet filter.
Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: What are the internal losses in centrifugal pumps? How did they come about?
Volume loss: loss due to leakage;3. mechanical loss
Q: Why can't the inlet of centrifugal pump be negative pressure?
Can be negative pressure ah, the negative pressure here refers to the pressure is less than the atmospheric pressure, but the pressure can not be too low, to prevent water vapor below the saturated vapor pressure, so that water vaporization, cavitation phenomenon, the centrifugal pump will be considered.
Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
Should shut down the valve bar, reduce the flow to increase the point of the head, it is best to adjust within the best range of work, otherwise it is easy to cause the current is too large, burning the motor
Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
The unit of displacement is the milliliter. How many milliliters does the pump rotate per circle? The displacement is the pump, the individual,The unit of flow is generally a liter, a figure added to the displacement of the pump over a period of time,
Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Pigment pressure is less than 0.4mpa,About 0.3. Go up.As the pump diaphragm is in the middle of a connecting rod, equivalent to the cylinder cavity, the pressure will be reduced; and because of the loss of pigment tube pressure will be reduced.
Q: What is the difference between the ground pump and the pump in the commercial concrete?
Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q: Attention should be paid to the use of pumps?
1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords