• High Voltage Static Var Compensator (SVC) System 1
  • High Voltage Static Var Compensator (SVC) System 2
  • High Voltage Static Var Compensator (SVC) System 3
  • High Voltage Static Var Compensator (SVC) System 4
  • High Voltage Static Var Compensator (SVC) System 5
High Voltage Static Var Compensator (SVC)

High Voltage Static Var Compensator (SVC)

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Technical Features:

SVC (Static Var Compensator) is composed of by thyristor controlled reactor (TCR) and passive filter (FC). It is a compensator with parallel connection in the grid, and it quickly and automatically adjust the system reactive power according to the load working condition.

 

Application Scope:

Reactive compensation and harmonic filtering of electric power, petroleum, chemical industry, metallurgy, wind power, photovoltaic power generation, hoist, electric arc furnace, electric locomotive, steel rolling production line, high voltage power lines, etc.

 

Product Principle


Combining with the control concept of current international mainstream, the heating power supply adopts the digital design to make the machine run more efficiently.

The heating power supply adopts the N + 1 redundancy technology to ensure the entire sapphire production cycle. We adopt DSP digital control mode, making the output voltage accuracy to five over ten thousand, and it has analog peripheral interface, 485 communication interface, etc. Using IGBT as power device to improve working efficiency and conform to the current trend of saving energy and reducing consumption.


Technical Features

1. Control system: We adopt American TI company DSP processor, which is of high control accuracy and high reliability. It employs PI control technology with advanced hardware and software. If there occurs fluctuation in power grid voltage, it can automatically maintain the current output power constantly.

2. HMI: It displays parameters in real time such as output voltage, current and power, etc.. It works with function of data maintained when power fails and it is easy to inquire and maintain the record of failure time and fault type.

3. High efficiency and low pollution: We adopt the phase shifting full bridge soft switching (ZVS) control technology, to realize the IGBT open and shut off under zero voltage. It greatly reduce the IGBT switching loss, the noise pollution and electromagnetic interference of the power. The output voltage waveform is completely smooth, and it runs more safe and stable.

4. High reliability: We adopt the multi-unit structure of N + 1, and the multiple units work together in normal condition. Failure of one unit does not affect the present output power and it is more convenient to maintain normal operation of equipment.

5. Perfect protection: Overtemperature protection and output over-voltage or over-current protection, output short circuit and grounding protection, the limit protection of water flow and strike fire protection, etc.

6. Flexible interface: Input and output support simulation approaches such as switch, voltage and current signal, Modbus, MB + and Profibus etc. data communications control.


Main Technical Parameters

AC InputInput voltage380V ±10%
Input current300A
Working frequency50(60}Hz±5%
DC OutputOutput Voltage0~18V
Stable-voltage precision<0.5%o< span="">
Current0-12500A
Overload capacity1.1*ln
Main characteristicsWork modeCV Cl CP
Power factor 0.95
Voltage distortion rate≤5%
Current distortion rate≤12%
Type of coolingWater cooling
ProtectionInput phase-deficientInput A、B、C three- phase, lose phase cause stop
Output overvoltage、over currentOver threshold cause stop
flow rate protectionDelayed-stop if water flow is less than setting value
Working environmentWater flow rate≥35L/Min
Water temperature5〜30℃
Water pressure0.15~0.6Mpa
Pressure between inlet and outlet0.08~0.6Mpa
Environment temperature5~40℃
Ambient humidity0 〜85% No condensation
Altitude≤1200m
Dimension(WxHxD) Size800 x 2200 x 1750 mm
Weight1000Kg

 

Q: S-350-12 monitoring dedicated switching power supply 12V29A transformer connection
16 road image 29a enough, it should be connected to the wrong line, you put the power picture up
Q: A led lamp with a dedicated power to bring a few lights
Second, the current market for some easy to burn the lamp beads 1, some manufacturers themselves are cottage factory, no engineering and technical personnel. Just buy other manufacturers to bring back the copy of the lights, and other manufacturers on the lamp with the current limiting resistor is how much, according to how much of the current limiting resistor. Do not know LED chips each batch of current are not the same, each batch should be based on the actual LED chip current limiting current limiting resistor. So that current limiting current limit is not enough, it led to some light belt easy to burn out of the situation. 2, the use of light with the customer is not clear the actual power of each light band, chaos with power, and the lights are often in a bright state, power supply is insufficient, eventually leading to light burned. 3, another reason: some power manufacturers to deceive consumers: the use of copper clad aluminum transformer, because the cooling effect of aluminum than copper transformer is poor, in the power, the power may be a time to achieve, but the power of a long time, power It can not afford the power of the lamp, it will burn the lamp, or burn the power.
Q: EPS emergency power supply and DC screen is one thing, what is the difference between the two?
DC screen [1] is a short description of the DC power supply operating system. Universal name for the intelligent maintenance-free DC power supply screen, referred to as DC screen, universal model for the GZDW. Simply put, the DC screen is to provide a stable DC power supply equipment. (Directly converted to DC220V or DC110V when inputting 380V power supply, and input directly to battery power when input (mains and standby) are input - DC 220V or DC110V: it can be said to be an industry Dedicated emergency power supply). Power plants and substations in the power of power supply are now used in DC power supply, which for the control load and power load and DC accident lighting load to provide power, is the basis of contemporary power system control and protection. The DC screen is composed of crossover power unit, charging module unit, step-down silicon chain unit, DC feed unit, power distribution monitoring unit, monitoring module unit and insulation monitoring unit. It is mainly used in small power plants, hydropower stations, substations, and other users of DC equipment (such as petrochemical, mining, railway, etc.) for power substation and sub-circuit. Electrical protection and fault lighting and other occasions.
Q: My magnetron is used in the industry, my dedicated power to start less than 2 minutes to stop,
3 power matching problem If you choose the magnetron power is lower than the lamp, the same point is not lit or strobe 4 waveguide shade design problem if you have mature technology this can be discharged
Q: Meizu special mobile power is which brand?
Meizu official did not move the power supply products, but before iWALK brand is designed for Meizu out of a 2500 mAh white mobile power, you can go to Jingdong Mall search.
Q: Industrial 380 inverter how to enter the home 220 power supply work
This is not the normal use of the. Can only say that you use the step-up isolation transformer 220V into a single-phase 380V power supply to the inverter, the inverter can only display, can not be normal with the motor
Q: Emergency lighting should not take fire special power supply, right?
3 .... in talking about emergency tools. All the emergency Deng has a fast battery and a module like the power of the things. (This thing with the fire touch a quick working principle, the module which has a normally open and normally closed point, when the electricity from the time he was Long open, the charging state, the mains of a short-circuit contacts normally closed, the battery will be through the module command to start the emergency lights. ???The building is the building of the 7th floor, 8th floor fire, the fire host to receive the fire signal, the host to the layer of fire strong cut a command: strong cut non-fire (this refers to the city's electricity is the lighting point ). When this layer is in a power failure state: The emergency principle according to Article 3. Emergency lights are not used fire power
Q: Computer power can be inserted in the air conditioning dedicated socket
The air conditioning socket can provide a greater current than the ordinary socket (not forcibly filling the electrical current).
Q: What is the difference between computer power and industrial switching power supply?
Industrial work conditions are poor, the temperature is high. Computer power is slightly lower. The other is almost the same
Q: What is the frequency of electricity in Bangladesh?
The People's Republic of Bangladesh (Bengali: G?n?pr?jat?ntri Bangladesh), referred to as Bangladesh and South Asian countries, is located in the north of the Bay of Bengal, a small part of the southeastern mountainous area and Myanmar neighbors, east, west and north are connected with India, and in the northern border A large number of enclaves, the total area of 147570 square kilometers.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords