• High Voltage Static Var Compensator (SVC) System 1
  • High Voltage Static Var Compensator (SVC) System 2
  • High Voltage Static Var Compensator (SVC) System 3
  • High Voltage Static Var Compensator (SVC) System 4
  • High Voltage Static Var Compensator (SVC) System 5
High Voltage Static Var Compensator (SVC)

High Voltage Static Var Compensator (SVC)

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Technical Features:

SVC (Static Var Compensator) is composed of by thyristor controlled reactor (TCR) and passive filter (FC). It is a compensator with parallel connection in the grid, and it quickly and automatically adjust the system reactive power according to the load working condition.

 

Application Scope:

Reactive compensation and harmonic filtering of electric power, petroleum, chemical industry, metallurgy, wind power, photovoltaic power generation, hoist, electric arc furnace, electric locomotive, steel rolling production line, high voltage power lines, etc.

 

Product Principle


Combining with the control concept of current international mainstream, the heating power supply adopts the digital design to make the machine run more efficiently.

The heating power supply adopts the N + 1 redundancy technology to ensure the entire sapphire production cycle. We adopt DSP digital control mode, making the output voltage accuracy to five over ten thousand, and it has analog peripheral interface, 485 communication interface, etc. Using IGBT as power device to improve working efficiency and conform to the current trend of saving energy and reducing consumption.


Technical Features

1. Control system: We adopt American TI company DSP processor, which is of high control accuracy and high reliability. It employs PI control technology with advanced hardware and software. If there occurs fluctuation in power grid voltage, it can automatically maintain the current output power constantly.

2. HMI: It displays parameters in real time such as output voltage, current and power, etc.. It works with function of data maintained when power fails and it is easy to inquire and maintain the record of failure time and fault type.

3. High efficiency and low pollution: We adopt the phase shifting full bridge soft switching (ZVS) control technology, to realize the IGBT open and shut off under zero voltage. It greatly reduce the IGBT switching loss, the noise pollution and electromagnetic interference of the power. The output voltage waveform is completely smooth, and it runs more safe and stable.

4. High reliability: We adopt the multi-unit structure of N + 1, and the multiple units work together in normal condition. Failure of one unit does not affect the present output power and it is more convenient to maintain normal operation of equipment.

5. Perfect protection: Overtemperature protection and output over-voltage or over-current protection, output short circuit and grounding protection, the limit protection of water flow and strike fire protection, etc.

6. Flexible interface: Input and output support simulation approaches such as switch, voltage and current signal, Modbus, MB + and Profibus etc. data communications control.


Main Technical Parameters

AC InputInput voltage380V ±10%
Input current300A
Working frequency50(60}Hz±5%
DC OutputOutput Voltage0~18V
Stable-voltage precision<0.5%o< span="">
Current0-12500A
Overload capacity1.1*ln
Main characteristicsWork modeCV Cl CP
Power factor 0.95
Voltage distortion rate≤5%
Current distortion rate≤12%
Type of coolingWater cooling
ProtectionInput phase-deficientInput A、B、C three- phase, lose phase cause stop
Output overvoltage、over currentOver threshold cause stop
flow rate protectionDelayed-stop if water flow is less than setting value
Working environmentWater flow rate≥35L/Min
Water temperature5〜30℃
Water pressure0.15~0.6Mpa
Pressure between inlet and outlet0.08~0.6Mpa
Environment temperature5~40℃
Ambient humidity0 〜85% No condensation
Altitude≤1200m
Dimension(WxHxD) Size800 x 2200 x 1750 mm
Weight1000Kg

 

Q: Industrial electricity in the DPS.UPS, etc. are temporary power to Caesar ah
Can be used as a delay power supply, but the power supply time is limited, according to the battery configuration,
Q: What is the allowable fluctuation range of the industrial standard power supply 380v power supply voltage?
With other levels of power supply voltage fluctuations are as follows: 35kV and above supply voltage positive and negative deviation of the absolute value does not exceed the nominal system voltage l0%. Note: If the upper and lower deviation of the electrical voltage (both positive or negative), according to the larger deviation of the absolute value as a basis for measurement.
Q: Dell 9020MT business computer can only use 290W dedicated power?
Yes. Dell 9020MT i7 version of the power supply is rated at 200W. 290w on the super. The rated power is the power at which the appliance is operating normally. Its value is the rated voltage of the appliance multiplied by the rated current. If the actual power of the appliance is greater than the rated power, the appliance may be damaged.
Q: Industrial plant design 10 kV substation from the power supply to the client side, such as mechanical equipment, such as the overall structure of the connection diagram
statistics good variety of required parameters; and then to the power distribution according to user needs to choose step-down transformer, draw high and low voltage system diagram, Details of the work and then slowly do ...
Q: Industrial 24V switching power supply outlet "-" Is it necessary to connect with the earth?
This line can be connected to the ground, if your cabinet shell ground, and this line can be connected to the shell. This is the role of the line with the earth is to prevent differential mode interference. If your equipment is used in a relatively large interference environment, such as around a large generator, which is the best grounding with the line. I actually encountered such a problem with the tower, the tower above the power supply is not grounded, tower crane at work, especially the switch is used when the contact switch is not solid state relay. Often on the disk, video surveillance system to restart or crash.
Q: Industrial 380 inverter how to enter the home 220 power supply work
Surely need to install the press
Q: US Industrial Electricity Voltage
2. Requirements for "Scope A": 115 ~ 120V System: When lighting: 110 ~ 125V of electrical equipment; power supply point 114 ~ 126V. No lighting: electrical equipment at 108 ~ 125V; power supply point 114 ~ 126V. 460 ~ 480V system: (including 480 / 277V three-phase four-wire system) When lighting: power equipment at 440 ~ 500V; power supply points 456 ~ 504V. No lighting: electricity equipment at 432 ~ 500V; power supply points 456 ~ 504V. 13200V system: power supply point 12870 ~ 13860V.
Q: Computer power can be inserted in the air conditioning dedicated socket
It should be noted that the air conditioning sockets are 16A / 250V specifications, jack distance greater than the ordinary 10A / 250V socket, so the computer power plug must be replaced by 16A socket can be inserted into the air conditioning socket. Therefore, the computer power plug in the use of air conditioning socket is possible.
Q: What is the industrial electricity voltage and frequency of Peru, Ecuador and Colombia?
Peru's industrial voltage and frequency are: [single phase] 110V / 220V, [three phase] 220V, [frequency] 60HZ;
Q: Led special power how to wiring
GND (three digits), then accept the light of the negative (usually black wire or white wire); 12V (three digits), then you light the positive pole (usually red wire or brown wire);