High Voltage Static Var Compensator (SVC)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 10 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Technical Features:
SVC (Static Var Compensator) is composed of by thyristor controlled reactor (TCR) and passive filter (FC). It is a compensator with parallel connection in the grid, and it quickly and automatically adjust the system reactive power according to the load working condition.
Application Scope:
Reactive compensation and harmonic filtering of electric power, petroleum, chemical industry, metallurgy, wind power, photovoltaic power generation, hoist, electric arc furnace, electric locomotive, steel rolling production line, high voltage power lines, etc.
Product Principle
Combining with the control concept of current international mainstream, the heating power supply adopts the digital design to make the machine run more efficiently.
The heating power supply adopts the N + 1 redundancy technology to ensure the entire sapphire production cycle. We adopt DSP digital control mode, making the output voltage accuracy to five over ten thousand, and it has analog peripheral interface, 485 communication interface, etc. Using IGBT as power device to improve working efficiency and conform to the current trend of saving energy and reducing consumption.
Technical Features
1. Control system: We adopt American TI company DSP processor, which is of high control accuracy and high reliability. It employs PI control technology with advanced hardware and software. If there occurs fluctuation in power grid voltage, it can automatically maintain the current output power constantly.
2. HMI: It displays parameters in real time such as output voltage, current and power, etc.. It works with function of data maintained when power fails and it is easy to inquire and maintain the record of failure time and fault type.
3. High efficiency and low pollution: We adopt the phase shifting full bridge soft switching (ZVS) control technology, to realize the IGBT open and shut off under zero voltage. It greatly reduce the IGBT switching loss, the noise pollution and electromagnetic interference of the power. The output voltage waveform is completely smooth, and it runs more safe and stable.
4. High reliability: We adopt the multi-unit structure of N + 1, and the multiple units work together in normal condition. Failure of one unit does not affect the present output power and it is more convenient to maintain normal operation of equipment.
5. Perfect protection: Overtemperature protection and output over-voltage or over-current protection, output short circuit and grounding protection, the limit protection of water flow and strike fire protection, etc.
6. Flexible interface: Input and output support simulation approaches such as switch, voltage and current signal, Modbus, MB + and Profibus etc. data communications control.
Main Technical Parameters
AC Input | Input voltage | 380V ±10% |
Input current | 300A | |
Working frequency | 50(60}Hz±5% | |
DC Output | Output Voltage | 0~18V |
Stable-voltage precision | <0.5%o< span=""> | |
Current | 0-12500A | |
Overload capacity | 1.1*ln | |
Main characteristics | Work mode | CV Cl CP |
Power factor | 0.95 | |
Voltage distortion rate | ≤5% | |
Current distortion rate | ≤12% | |
Type of cooling | Water cooling | |
Protection | Input phase-deficient | Input A、B、C three- phase, lose phase cause stop |
Output overvoltage、over current | Over threshold cause stop | |
flow rate protection | Delayed-stop if water flow is less than setting value | |
Working environment | Water flow rate | ≥35L/Min |
Water temperature | 5〜30℃ | |
Water pressure | 0.15~0.6Mpa | |
Pressure between inlet and outlet | 0.08~0.6Mpa | |
Environment temperature | 5~40℃ | |
Ambient humidity | 0 〜85% No condensation | |
Altitude | ≤1200m | |
Dimension | (WxHxD) Size | 800 x 2200 x 1750 mm |
Weight | 1000Kg |
- Q: What is the frequency of industrial electricity in the Philippines?
- China's electricity voltage and frequency: Voltage: Resident 220V, Industrial 380V. Distribution: 10 000V, up there 35kV, 110kV, 220kV, 330kV, 500kV, 750kV, 1000kV. Frequency: 50 HZ.
- Q: S-350-12 monitoring dedicated switching power supply 12V29A transformer connection
- may 1, you are on the wiring when the burning, it is the power is not big enough, is overloaded work. 2, you do not connect, may be connected together positive and negative, resulting in short circuit burned. Recommendation: change the new power supply, it is necessary to connect all the lines, and then the first group, to see the heat situation, to determine whether the next group.
- Q: Power for ups power supply which well-known imported brands
- Emerson (Emerson), Merlin Gerin (MGE) This is the best power of the two brands. China Telecom, mobile, China Unicom, PetroChina and other cattle are the use of these two brands of cattle. APC, Hills is the best two brands of low power. Telecommunications, mobile, Unicom and other business units may be more use. Emerson has a dedicated UPS for power and other industries. Need to contact me.
- Q: EPS emergency power supply and DC screen is one thing, what is the difference between the two?
- Mainly used in road traffic lighting, venue lighting, building fire escape lighting, fire pumps, spray pumps and other fire equipment to provide emergency power supply, EPS fire emergency power supply through the CCC China national compulsory product certification, the current state through the 3C certified EPS Fire emergency power supply size is 0.5KVA to 110KVA. EPS fire emergency power supply can be divided into emergency lighting, hybrid and power inverter EPS emergency power supply three categories.
- Q: Industrial electricity in the DPS.UPS, etc. are temporary power to Caesar ah
- and some can delay a few minutes, some can be delayed for several hours, but if the request for a few days that can not be achieved, Only when the temporary power supply
- Q: Industrial plant design 10 kV substation from the power supply to the client side, such as mechanical equipment, such as the overall structure of the connection diagram
- statistics good variety of required parameters; and then to the power distribution according to user needs to choose step-down transformer, draw high and low voltage system diagram, Details of the work and then slowly do ...
- Q: Industrial switching power supply which brand is good, including imported.
- Mingwei, Heng Fu, Mao Shuo, Huawei, Kang Su, Nova, a joint, and so on, too bad to say
- Q: US Industrial Electricity Voltage
- 2. Requirements for "Scope A": 115 ~ 120V System: When lighting: 110 ~ 125V of electrical equipment; power supply point 114 ~ 126V. No lighting: electrical equipment at 108 ~ 125V; power supply point 114 ~ 126V. 460 ~ 480V system: (including 480 / 277V three-phase four-wire system) When lighting: power equipment at 440 ~ 500V; power supply points 456 ~ 504V. No lighting: electricity equipment at 432 ~ 500V; power supply points 456 ~ 504V. 13200V system: power supply point 12870 ~ 13860V.
- Q: Industrial power cabinet generally use what brand of power
- 3.APC, the old brand, was EMERSON acquisition, but the market share and then gradually reduced.
- Q: Fire emergency lights and evacuation signs need to receive a dedicated fire power on it?
- The effect of the fire emergency light is to provide emergency evacuation lighting after the circuit is powered off, which is characterized by being controlled when the power supply is normal and providing temporary emergency lighting from the internal battery when the power supply fails (power failure).
Send your message to us
High Voltage Static Var Compensator (SVC)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 10 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords