• Low Voltage Reactive Power Compensat SY-TSF Series System 1
Low Voltage Reactive Power Compensat SY-TSF Series

Low Voltage Reactive Power Compensat SY-TSF Series

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Application Scope

Reactive compensation and harmonic filtering of electric power, petroleum, steel, chemical, metallurgy, wind power, semiconductor manufacturing, water supply and drainage industry.

Technical Features:

SY-TSF low-voltage SVG and harmonic filter are designed for load of large harmonic content and with rapidly changing reactive power compensation (eg. welder, rolling DC motor, frequency converter, etc.). The device can automatically track the load changing condition and control the automatic switching of each filter branch in real-time to make the power factor of system stay in the best value while filtering load harmonic current.


SY-TSC-□/□/-660


NO.

Installed Capacity

(kvar)

Fundamental  Capacity

(kvar)

Grading Manner

(Coding)

compensation precision

(kvar)

Compensator Num.

(set)

Installed

Filter


Compensation Cabinet Size

(L*D*H)

Compensator Capacity

(kvar)

DC Drive for Reference

(kW)

1600400

Coding

1:2:4
5715times1200*1000*2200600500
2780520

Coding

1:2:4
7425times1000*1000*2200
1000*1000*2200
279+501650
3900600

Coding

1:2:4
8625times1000*1000*2200
1100*1000*2200
323+577750
4960640

Coding

1:2:4
9125times1000*1000*2200
1200*1000*2200
341+619800
51080720

Coding

1:2:2:2
10325、7times1000*1000*2200
1200*1000*2200
446+634900
61200800

Coding

1:2:2:2
11435、7times1000*1000*2200
800*1000*2200
800*1000*2200
496+352+3521000
71320880

Coding

1:2:2:2
12635、7times1100*1000*2200
800*1000*2200
800*1000*2200
546+387+3872×650
815001000

Coding

1:2:4:4
9135times1000*1000*2200
1100*1000*2200
1100*1000*2200
342+579+5791250
916201080

Coding

1:2:4:4
9835times1000*1000*2200
1200*1000*2200
1200*1000*2200
368+626+6261350
1018001200

Coding

1:2:4:4:4
8045、7times1000*1000*2200
1000*1000*2200
1000*1000*2200
1000*1000*2200
300+500+500+5001500
1119201280

Coding

1:2:4:4:4
8545、7times1000*1000*2200
1100*1000*2200
1100*1000*2200
1100*1000*2200
318+534+534+5341600
1220401360

Coding

1:2:4:4:4
9145、7times1000*1000*2200
1100*1000*2200
1100*1000*2200
1100*1000*2200
342+566+566+5662×1000

 
SY-TSF-□/□-400型

NO.

Installed Capacity

(kvar)

Fundamental  Capacity

(kvar)

Grading Manner

(Coding)

compensation precision

(kvar)

Compensator Num.

(set)



Installed

Filter

Compensation Cabinet Size

(L*D*H)

Compensator Capacity

(kvar)

Transformer for Reference

( kVA)

112080

Coding

1:2
2715times800*1000*2200120160
2180120

Coding

1:2
4015times800*1000*2200180250
3250167

Coding

1:2:4
2415times1000*1000*2200250315
4300200

Coding

1:2:4
2915times1000*1000*2200300400
5350233

Coding

1:2:4
3315times1000*1000*2200350500
6400267

Coding

1:2:4
3815times1100*1000*2200400500
7500333

Coding

1:2:4
4815times1200*1000*2200500630
8600400

Coding

1:2:4
5725times1000*1000*2200
800*1000*2200
214+386800
9700467

Coding

1:2:4:4
4225times1000*1000*2200
1000*1000*2200
324+3761000
10800533

Coding

1:2:4:4
4825、7times1100*1000*2200
1000*1000*2200
370+4301000
11900600

Coding

1:2:4:4
5525、7times1100*1000*2200
1000*1000*2200
415+4851250
121000667

Coding

1:2:4:4
6125、7times1200*1000*2200
1000*1000*2200
462+5381250
131200800

Coding

1:2:4:4:4
5335、7times1000*1000*2200
1000*1000*2200
800*1000*2200
400+466+334
(1+4)+(2+4)+4
1600
141350900

Coding

1:2:4:4:4
6035、7times1100*1000*2200
1000*1000*2200
800*1000*2200
450+525+375
(1+4)+(2+4)+4
1600
1515001000

Coding

1:2:4:4:4
6735、7times1200*1000*2200
1100*1000*2200
900*1000*2200
500+584+416
(1+4)+(2+4)+4
2000
1616001067

Coding

1:2:4:4:4:4
5645、7times1100*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
417+487+348+348
(1+4)+(2+4)+4+4
2000
1718001200

Coding

1:2:4:4:4:4
6345、7times1100*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
415+479+353+353
(1+4)+(2+4)+4+4
2000
1820001333

Coding

1:2:4:4:4:4
7045、7times1200*1000*2200
1100*1000*2200
900*1000*2200
900*1000*2200
522+610+434+434
(1+4)+(2+4)+4+4
2500
1922501500

Coding

1:2:4:4:4:4:4
6555、7、11times1200*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
800*1000*2200
483+564+401+401+401
(1+4)+(2+4)+4+4+4
2500
2025001667

Coding

1:2:4:4:4:4:4
7255、7、11times1200*1000*2200
1100*1000*2200
900*1000*2200
900*1000*2200
900*1000*2200
536+626+446+446+446
(1+4)+(2+4)+4+4+4
3150Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements.

Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements

           2. The data in the table are for reference only, we reserve the right to change the data.

           3. It suggests adding a head line-in switch if the installed capacity is more than 1000kvar.

 

Q: S-350-12 monitoring dedicated switching power supply 12V29A transformer connection
16 road image 29a enough, it should be connected to the wrong line, you put the power picture up
Q: My magnetron is used in the industry, my dedicated power to start less than 2 minutes to stop,
3 power matching problem If you choose the magnetron power is lower than the lamp, the same point is not lit or strobe 4 waveguide shade design problem if you have mature technology this can be discharged
Q: Do you want to use the DC24V of the alarm system for the power cord of the bus-specific fire-fighting telephone?
I have not seen the telephone extension to use 24V power supply, are generally by the fire center bus phone host pull two pairs of lines to the bus phone module (two pairs of lines are the telephone audio line and telephone bus), and then from the phone module Pull a pair of lines to the telephone extension (this line for the telephone audio line).
Q: PIC microcontroller used in the industrial field, the power supply using switching power supply plus B0505 isolation module, anti-jamming performance is better
There is no direct relationship between isolation and anti-interference. If you can not remove the interference source, cut off the interference source transmission path is an effective method. Power supply interference can be considered using the power filter.
Q: Industrial 24V switching power supply outlet "-" Is it necessary to connect with the earth?
ndustrial 24V switching power supply outlet "-" There is a need and the earth connected. The negative grounding of the power supply can greatly prevent the differential mode interference and improve the stability of the circuit.
Q: What is the application of IF power supply in the industrial field?
1, smelting furnace metal smelting: This is one of the most widely used aspects of the development of China's thyristor power, began in the smelting, melting all kinds of carbon steel, alloy steel, alloy cast iron, copper and aluminum can also be, and Used to extract high purity zinc and other non-ferrous metals. Smelting load is the worst load of medium frequency power supply, yin anti-change is large, the load is unstable, but the intermediate frequency power supply can be very ideal to complete this task, the most prominent advantage is to save energy, every smelting IT steel power consumption around 500KW.h. Also easy to start, smooth steel, eddy water mixing small, good quality smelting.
Q: Meizu special mobile power is which brand?
Meizu custom iWalk, but the evaluation is not high. Meizu phone on the current with the voltage is a more accurate requirements Oh, please Meizu mobile phone battery according to the technical parameters of regular manufacturers and users to evaluate the high product, the proposed choice of current 1.2A, voltage 5V. Part of the mobile power will be virtual standard, while the wire, mobile power supply itself will be some resistance to wear, before the purchase with the original data cable test.
Q: Emergency lighting should not take fire special power supply, right?
1. ** building building 7 # 8 floor, a fire, the fire control room will receive the smoke into the floor or the temperature of the signal, the host allows all the automatic circumstances, will be linked to the fan to The floor into the 7.8.9 layer to open the wind valve, raw light will start, if the floor of the spray forest are all allowed to spray the forest will start, etc., this is the principle.
Q: Why do you need to use isolated power in industrial communications?
In simple terms, the need for isolation mainly involves: communication equipment on the power of the stability and anti-interference requirements are high,
Q: Site with industrial power 380V / 50hz, electrical equipment is 110v / 60hz. Is there a solution?
The simplest solution, no 380v, 220v direct lighting, then 220v turn 110v transformer, output 110v, 50hz, then the equipment. Not a big problem