• Low Voltage Reactive Power Compensat SY-TSF Series System 1
Low Voltage Reactive Power Compensat SY-TSF Series

Low Voltage Reactive Power Compensat SY-TSF Series

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Application Scope

Reactive compensation and harmonic filtering of electric power, petroleum, steel, chemical, metallurgy, wind power, semiconductor manufacturing, water supply and drainage industry.

Technical Features:

SY-TSF low-voltage SVG and harmonic filter are designed for load of large harmonic content and with rapidly changing reactive power compensation (eg. welder, rolling DC motor, frequency converter, etc.). The device can automatically track the load changing condition and control the automatic switching of each filter branch in real-time to make the power factor of system stay in the best value while filtering load harmonic current.


SY-TSC-□/□/-660


NO.

Installed Capacity

(kvar)

Fundamental  Capacity

(kvar)

Grading Manner

(Coding)

compensation precision

(kvar)

Compensator Num.

(set)

Installed

Filter


Compensation Cabinet Size

(L*D*H)

Compensator Capacity

(kvar)

DC Drive for Reference

(kW)

1600400

Coding

1:2:4
5715times1200*1000*2200600500
2780520

Coding

1:2:4
7425times1000*1000*2200
1000*1000*2200
279+501650
3900600

Coding

1:2:4
8625times1000*1000*2200
1100*1000*2200
323+577750
4960640

Coding

1:2:4
9125times1000*1000*2200
1200*1000*2200
341+619800
51080720

Coding

1:2:2:2
10325、7times1000*1000*2200
1200*1000*2200
446+634900
61200800

Coding

1:2:2:2
11435、7times1000*1000*2200
800*1000*2200
800*1000*2200
496+352+3521000
71320880

Coding

1:2:2:2
12635、7times1100*1000*2200
800*1000*2200
800*1000*2200
546+387+3872×650
815001000

Coding

1:2:4:4
9135times1000*1000*2200
1100*1000*2200
1100*1000*2200
342+579+5791250
916201080

Coding

1:2:4:4
9835times1000*1000*2200
1200*1000*2200
1200*1000*2200
368+626+6261350
1018001200

Coding

1:2:4:4:4
8045、7times1000*1000*2200
1000*1000*2200
1000*1000*2200
1000*1000*2200
300+500+500+5001500
1119201280

Coding

1:2:4:4:4
8545、7times1000*1000*2200
1100*1000*2200
1100*1000*2200
1100*1000*2200
318+534+534+5341600
1220401360

Coding

1:2:4:4:4
9145、7times1000*1000*2200
1100*1000*2200
1100*1000*2200
1100*1000*2200
342+566+566+5662×1000

 
SY-TSF-□/□-400型

NO.

Installed Capacity

(kvar)

Fundamental  Capacity

(kvar)

Grading Manner

(Coding)

compensation precision

(kvar)

Compensator Num.

(set)



Installed

Filter

Compensation Cabinet Size

(L*D*H)

Compensator Capacity

(kvar)

Transformer for Reference

( kVA)

112080

Coding

1:2
2715times800*1000*2200120160
2180120

Coding

1:2
4015times800*1000*2200180250
3250167

Coding

1:2:4
2415times1000*1000*2200250315
4300200

Coding

1:2:4
2915times1000*1000*2200300400
5350233

Coding

1:2:4
3315times1000*1000*2200350500
6400267

Coding

1:2:4
3815times1100*1000*2200400500
7500333

Coding

1:2:4
4815times1200*1000*2200500630
8600400

Coding

1:2:4
5725times1000*1000*2200
800*1000*2200
214+386800
9700467

Coding

1:2:4:4
4225times1000*1000*2200
1000*1000*2200
324+3761000
10800533

Coding

1:2:4:4
4825、7times1100*1000*2200
1000*1000*2200
370+4301000
11900600

Coding

1:2:4:4
5525、7times1100*1000*2200
1000*1000*2200
415+4851250
121000667

Coding

1:2:4:4
6125、7times1200*1000*2200
1000*1000*2200
462+5381250
131200800

Coding

1:2:4:4:4
5335、7times1000*1000*2200
1000*1000*2200
800*1000*2200
400+466+334
(1+4)+(2+4)+4
1600
141350900

Coding

1:2:4:4:4
6035、7times1100*1000*2200
1000*1000*2200
800*1000*2200
450+525+375
(1+4)+(2+4)+4
1600
1515001000

Coding

1:2:4:4:4
6735、7times1200*1000*2200
1100*1000*2200
900*1000*2200
500+584+416
(1+4)+(2+4)+4
2000
1616001067

Coding

1:2:4:4:4:4
5645、7times1100*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
417+487+348+348
(1+4)+(2+4)+4+4
2000
1718001200

Coding

1:2:4:4:4:4
6345、7times1100*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
415+479+353+353
(1+4)+(2+4)+4+4
2000
1820001333

Coding

1:2:4:4:4:4
7045、7times1200*1000*2200
1100*1000*2200
900*1000*2200
900*1000*2200
522+610+434+434
(1+4)+(2+4)+4+4
2500
1922501500

Coding

1:2:4:4:4:4:4
6555、7、11times1200*1000*2200
1000*1000*2200
800*1000*2200
800*1000*2200
800*1000*2200
483+564+401+401+401
(1+4)+(2+4)+4+4+4
2500
2025001667

Coding

1:2:4:4:4:4:4
7255、7、11times1200*1000*2200
1100*1000*2200
900*1000*2200
900*1000*2200
900*1000*2200
536+626+446+446+446
(1+4)+(2+4)+4+4+4
3150Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements.

Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements

           2. The data in the table are for reference only, we reserve the right to change the data.

           3. It suggests adding a head line-in switch if the installed capacity is more than 1000kvar.

 

Q: What is the frequency of industrial electricity in the Philippines?
Frequency, is the unit time to complete the number of cyclical changes, is to describe the amount of periodic movement frequency, commonly used symbols f or u said, in units of seconds. In order to commemorate the German physicist Hertz's contribution, people put the frequency of the unit named Hertz, referred to as "He". Each object has an amplitude independent of its own nature, called the natural frequency. The concept of frequency is not only used in mechanics, acoustics, but also in electromagnetics and radio technology.
Q: S-350-12 monitoring dedicated switching power supply 12V29A transformer connection
may 1, you are on the wiring when the burning, it is the power is not big enough, is overloaded work. 2, you do not connect, may be connected together positive and negative, resulting in short circuit burned. Recommendation: change the new power supply, it is necessary to connect all the lines, and then the first group, to see the heat situation, to determine whether the next group.
Q: Military grade power supply, industrial power supply, civil power supply where the difference?
Industrial power supply, there is no military power there is strict. Civil power, that is, we generally use the power, not very strict requirements, but there must be in the request,
Q: Dell 9020MT business computer can only use 290W dedicated power?
In the normal operation of the working conditions, the power of the power output or power consumption of equipment input power. Often "kilowatts" as a unit. Also refers to the factory production of the machine in the normal work can reach the power.
Q: With tl494 and do with UC3842 Which power is better?
3842 is a single output, the general switching power supply are used, TL494 is a dual output, can be made into complementary output, can also be made into a single output is mainly used in computer power .3842 simple, 494 complex point of stability and efficiency! Mainly on the power of the design
Q: The 2-way power supply is connected to a 16A 8-bit PDU in the cabinet using a 16A industrial connector
1 Road 16A into, just connected to the 16APDU Lane, just right. Second Road, then it is estimated that a then electricity, a UPS. Smart is not intelligent and it does not matter. A little better room will be equipped with this.
Q: Industrial switching power supply which brand is good, including imported.
Taiwan Mingwei Many domestic countries are imitation of it. Foreign switching power supply to do less, more than 75% of the world in the mainland.
Q: Industrial power cabinet generally use what brand of power
At present, industrial UPS, the market usually use several brands. 1.EMERSON, EMERSON not only provide UPS products, but also provide supporting engineering solutions and engineering support.
Q: Led special power how to wiring
GND (three digits), then accept the light of the negative (usually black wire or white wire); 12V (three digits), then you light the positive pole (usually red wire or brown wire);
Q: Driving recorder dedicated power box for what use
4) recommended after the stop do not video, use is not to say, easy to consume too much car battery power. 5) cigarette lighter mouth plug recorder use, automatic shutdown after the car is turned off, will not consume battery power.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords