Low Voltage Reactive Power Compensat SY-TSF Series
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 10 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application Scope
Reactive compensation and harmonic filtering of electric power, petroleum, steel, chemical, metallurgy, wind power, semiconductor manufacturing, water supply and drainage industry.
Technical Features:
SY-TSF low-voltage SVG and harmonic filter are designed for load of large harmonic content and with rapidly changing reactive power compensation (eg. welder, rolling DC motor, frequency converter, etc.). The device can automatically track the load changing condition and control the automatic switching of each filter branch in real-time to make the power factor of system stay in the best value while filtering load harmonic current.
SY-TSC-□/□/-660
NO. | Installed Capacity (kvar) | Fundamental Capacity (kvar) | Grading Manner (Coding) | compensation precision (kvar) | Compensator Num. (set) | Installed Filter | Compensation Cabinet Size (L*D*H) | Compensator Capacity (kvar) | DC Drive for Reference (kW) |
1 | 600 | 400 | Coding 1:2:4 | 57 | 1 | 5times | 1200*1000*2200 | 600 | 500 |
2 | 780 | 520 | Coding 1:2:4 | 74 | 2 | 5times | 1000*1000*2200 1000*1000*2200 | 279+501 | 650 |
3 | 900 | 600 | Coding 1:2:4 | 86 | 2 | 5times | 1000*1000*2200 1100*1000*2200 | 323+577 | 750 |
4 | 960 | 640 | Coding 1:2:4 | 91 | 2 | 5times | 1000*1000*2200 1200*1000*2200 | 341+619 | 800 |
5 | 1080 | 720 | Coding 1:2:2:2 | 103 | 2 | 5、7times | 1000*1000*2200 1200*1000*2200 | 446+634 | 900 |
6 | 1200 | 800 | Coding 1:2:2:2 | 114 | 3 | 5、7times | 1000*1000*2200 800*1000*2200 800*1000*2200 | 496+352+352 | 1000 |
7 | 1320 | 880 | Coding 1:2:2:2 | 126 | 3 | 5、7times | 1100*1000*2200 800*1000*2200 800*1000*2200 | 546+387+387 | 2×650 |
8 | 1500 | 1000 | Coding 1:2:4:4 | 91 | 3 | 5times | 1000*1000*2200 1100*1000*2200 1100*1000*2200 | 342+579+579 | 1250 |
9 | 1620 | 1080 | Coding 1:2:4:4 | 98 | 3 | 5times | 1000*1000*2200 1200*1000*2200 1200*1000*2200 | 368+626+626 | 1350 |
10 | 1800 | 1200 | Coding 1:2:4:4:4 | 80 | 4 | 5、7times | 1000*1000*2200 1000*1000*2200 1000*1000*2200 1000*1000*2200 | 300+500+500+500 | 1500 |
11 | 1920 | 1280 | Coding 1:2:4:4:4 | 85 | 4 | 5、7times | 1000*1000*2200 1100*1000*2200 1100*1000*2200 1100*1000*2200 | 318+534+534+534 | 1600 |
12 | 2040 | 1360 | Coding 1:2:4:4:4 | 91 | 4 | 5、7times | 1000*1000*2200 1100*1000*2200 1100*1000*2200 1100*1000*2200 | 342+566+566+566 | 2×1000 |
SY-TSF-□/□-400型
NO. | Installed Capacity (kvar) | Fundamental Capacity (kvar) | Grading Manner (Coding) | compensation precision (kvar) | Compensator Num. (set) | Installed Filter | Compensation Cabinet Size (L*D*H) | Compensator Capacity (kvar) | Transformer for Reference ( kVA) |
1 | 120 | 80 | Coding 1:2 | 27 | 1 | 5times | 800*1000*2200 | 120 | 160 |
2 | 180 | 120 | Coding 1:2 | 40 | 1 | 5times | 800*1000*2200 | 180 | 250 |
3 | 250 | 167 | Coding 1:2:4 | 24 | 1 | 5times | 1000*1000*2200 | 250 | 315 |
4 | 300 | 200 | Coding 1:2:4 | 29 | 1 | 5times | 1000*1000*2200 | 300 | 400 |
5 | 350 | 233 | Coding 1:2:4 | 33 | 1 | 5times | 1000*1000*2200 | 350 | 500 |
6 | 400 | 267 | Coding 1:2:4 | 38 | 1 | 5times | 1100*1000*2200 | 400 | 500 |
7 | 500 | 333 | Coding 1:2:4 | 48 | 1 | 5times | 1200*1000*2200 | 500 | 630 |
8 | 600 | 400 | Coding 1:2:4 | 57 | 2 | 5times | 1000*1000*2200 800*1000*2200 | 214+386 | 800 |
9 | 700 | 467 | Coding 1:2:4:4 | 42 | 2 | 5times | 1000*1000*2200 1000*1000*2200 | 324+376 | 1000 |
10 | 800 | 533 | Coding 1:2:4:4 | 48 | 2 | 5、7times | 1100*1000*2200 1000*1000*2200 | 370+430 | 1000 |
11 | 900 | 600 | Coding 1:2:4:4 | 55 | 2 | 5、7times | 1100*1000*2200 1000*1000*2200 | 415+485 | 1250 |
12 | 1000 | 667 | Coding 1:2:4:4 | 61 | 2 | 5、7times | 1200*1000*2200 1000*1000*2200 | 462+538 | 1250 |
13 | 1200 | 800 | Coding 1:2:4:4:4 | 53 | 3 | 5、7times | 1000*1000*2200 1000*1000*2200 800*1000*2200 | 400+466+334 (1+4)+(2+4)+4 | 1600 |
14 | 1350 | 900 | Coding 1:2:4:4:4 | 60 | 3 | 5、7times | 1100*1000*2200 1000*1000*2200 800*1000*2200 | 450+525+375 (1+4)+(2+4)+4 | 1600 |
15 | 1500 | 1000 | Coding 1:2:4:4:4 | 67 | 3 | 5、7times | 1200*1000*2200 1100*1000*2200 900*1000*2200 | 500+584+416 (1+4)+(2+4)+4 | 2000 |
16 | 1600 | 1067 | Coding 1:2:4:4:4:4 | 56 | 4 | 5、7times | 1100*1000*2200 1000*1000*2200 800*1000*2200 800*1000*2200 | 417+487+348+348 (1+4)+(2+4)+4+4 | 2000 |
17 | 1800 | 1200 | Coding 1:2:4:4:4:4 | 63 | 4 | 5、7times | 1100*1000*2200 1000*1000*2200 800*1000*2200 800*1000*2200 | 415+479+353+353 (1+4)+(2+4)+4+4 | 2000 |
18 | 2000 | 1333 | Coding 1:2:4:4:4:4 | 70 | 4 | 5、7times | 1200*1000*2200 1100*1000*2200 900*1000*2200 900*1000*2200 | 522+610+434+434 (1+4)+(2+4)+4+4 | 2500 |
19 | 2250 | 1500 | Coding 1:2:4:4:4:4:4 | 65 | 5 | 5、7、11times | 1200*1000*2200 1000*1000*2200 800*1000*2200 800*1000*2200 800*1000*2200 | 483+564+401+401+401 (1+4)+(2+4)+4+4+4 | 2500 |
20 | 2500 | 1667 | Coding 1:2:4:4:4:4:4 | 72 | 5 | 5、7、11times | 1200*1000*2200 1100*1000*2200 900*1000*2200 900*1000*2200 900*1000*2200 | 536+626+446+446+446 (1+4)+(2+4)+4+4+4 | 3150Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements. |
Note: 1. The voltage grade, capacity and grading manner can be made according to customer requirements
2. The data in the table are for reference only, we reserve the right to change the data.
3. It suggests adding a head line-in switch if the installed capacity is more than 1000kvar.
- Q:The 2-way power supply is connected to a 16A 8-bit PDU in the cabinet using a 16A industrial connector
- 1 Road 16A into, just connected to the 16APDU Lane, just right. Second Road, then it is estimated that a then electricity, a UPS. Smart is not intelligent and it does not matter. A little better room will be equipped with this.
- Q:Emergency lighting should not take fire special power supply, right?
- 1. ** building building 7 # 8 floor, a fire, the fire control room will receive the smoke into the floor or the temperature of the signal, the host allows all the automatic circumstances, will be linked to the fan to The floor into the 7.8.9 layer to open the wind valve, raw light will start, if the floor of the spray forest are all allowed to spray the forest will start, etc., this is the principle.
- Q:Industrial electricity (380V) what the color of the wire, which is the line of fire, which is the zero line
- 30KW current about 60A or so, calculated by P = ui to calculate, mainly to consider the line voltage and phase voltage conversion, 380V should be replaced by phase voltage. ? 60A of the meter generally do not have to consider the installation of a more current transformer, 75 / 5A on the line, so that the secondary current in the 4 amps, the meter with 5A on the line, calculate the power when remember to multiply 15 times.
- Q:What brand of power control module is better? You know MINMAX and C & D two brands.
- Look at your main application. If cheap cheap goods, everywhere, a search on the Internet, a lot. But the quality of good and bad, you have to grasp yourself.
- Q:UPS uninterruptible power supplies, electronic power products, industrial computers and embedded computers.
- This is really hard to say, do sales, compared to the technical content of the product, more need is the sales skills. When you decide to engage in the sales industry, selling a product, sales can reflect your value, rather than the product itself, the technical content.
- Q:Industrial power cabinet generally use what brand of power
- 2.PowerWARE, EATON subordinate brands, including SANTAK is EATON's brand, also accept direct engineering orders, that is to provide products while also providing engineering services and engineering warranty service.
- Q:Dell 9020MT business computer can only use 290W dedicated power?
- In the normal operation of the working conditions, the power of the power output or power consumption of equipment input power. Often "kilowatts" as a unit. Also refers to the factory production of the machine in the normal work can reach the power.
- Q:Military grade power supply, industrial power supply, civil power supply where the difference?
- Military-grade power supply, demanding, such as waterproof, fire, drop and so on are required,
- Q:Industrial control system power supply Why is the choice of DC24V power supply? Why not 17V? 11V?
- which take into account a number of factors, the first is a safe voltage, the body does not produce electric shock Dangerous, the second can be regarded as a relatively high safety voltage, can reduce the current in the same power, and then 24 is a multiples of the majority, set the standard, of course, to consider and a variety of batteries are also concerned,
- Q:What is the frequency of industrial electricity in the Philippines?
- Frequency, is the unit time to complete the number of cyclical changes, is to describe the amount of periodic movement frequency, commonly used symbols f or u said, in units of seconds. In order to commemorate the German physicist Hertz's contribution, people put the frequency of the unit named Hertz, referred to as "He". Each object has an amplitude independent of its own nature, called the natural frequency. The concept of frequency is not only used in mechanics, acoustics, but also in electromagnetics and radio technology.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Low Voltage Reactive Power Compensat SY-TSF Series
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 10 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords