Sapphire Single-phase Power Frequency Furnace Heating Power Supply
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 50 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application Scope
Sapphire single-phase power frequency furnace heating power supply is mainly for the gem furnace which needs of single-phase AC power supply. The product can provide power output with high precision and reliability for the sapphire furnace production process, so as to ensure temperature stability of the sapphire crystal process.
Product Principle
It adopts transformers primary lateral pressure regulating and secondary lateral voltage reducing. Use transformer primary side and secondary side voltage regulator voltage output. With double closed loop control in the whole process, the output voltage is of high precision and high reliability.
Technical Features:
1. Flexible operation and convenient maintenance: It installs LCD (Liquid Crystal Display) monitor panel and displays operation parameters in real time. The control parameters can be modified online and fault information can be automatically recorded, etc.
2. High control accuracy and good stability: It adopts phase-locked loop synchronous circuit and 16-bit digital trigger. It does voltage and current sampling by True-RMS calculation chip. It is designed of multiple software protection function for overvoltage, overcurrent, overheating, feedback disconnection and lack of phase alarm etc. The power devices and circuit breaker etc. adopt international and domestic famous brands.
3. Advanced processing technology of transformer: Transformer adopts high-low pressure complete foil coil winding, step laminated and damping measures. It is with merits of low noise and loss, light weight with small volume, and saving installation space. It has strong heat dissipation ability to achieve 20% overload running stably under the condition of forced air cooling.
4. Digital communication control:It control the output power of power supply cabinet through the MODBUS communication mode and read the real value of output voltage, current and fault type, etc.
Main Technical Parameters
AC Input | Input voltage | AC380V±10% |
Input current | 300A | |
Working frequency | 50(60>Hz±5% | |
AC Output | Output Voltage | 0 〜15V |
Stable-voltage precision | <1%o< span=""> | |
Current | 0-8000A | |
Overload capacity | 1.1*In | |
Main characteristics | Work mode | cv |
Type of cooling | Wind cooling | |
Protection | Input phase-deficient | Input A、B、C three- phase, lose phase cause stop |
Output overvoltage、over current | Over threshold cause stop | |
Environment temperature | 5~40℃ | |
Ambient humidity | 0 〜85% No condensation | |
Altitude | ≤1200m | |
Dimension | (HxWxD) Size | 2050 x 820 x 1750 mm |
Weight | 1000Kg |
- Q:The 2-way power supply is connected to a 16A 8-bit PDU in the cabinet using a 16A industrial connector
- 1 Road 16A into, just connected to the 16APDU Lane, just right. Second Road, then it is estimated that a then electricity, a UPS. Smart is not intelligent and it does not matter. A little better room will be equipped with this.
- Q:What is the industrial electricity voltage and frequency of Peru, Ecuador and Colombia?
- Colombia's industrial voltage and frequency are: [single phase] 110V / 220V, [three phase] 220V, [frequency] 60HZ;
- Q:UPS uninterruptible power supplies, electronic power products, industrial computers and embedded computers.
- This is really hard to say, do sales, compared to the technical content of the product, more need is the sales skills. When you decide to engage in the sales industry, selling a product, sales can reflect your value, rather than the product itself, the technical content.
- Q:PIC microcontroller used in the industrial field, the power supply using switching power supply plus B0505 isolation module, anti-jamming performance is better
- Certainly better, or else else to develop this power module why? All with a direct switch power supply! The
- Q:US Industrial Electricity Voltage
- 2. Requirements for "Scope A": 115 ~ 120V System: When lighting: 110 ~ 125V of electrical equipment; power supply point 114 ~ 126V. No lighting: electrical equipment at 108 ~ 125V; power supply point 114 ~ 126V. 460 ~ 480V system: (including 480 / 277V three-phase four-wire system) When lighting: power equipment at 440 ~ 500V; power supply points 456 ~ 504V. No lighting: electricity equipment at 432 ~ 500V; power supply points 456 ~ 504V. 13200V system: power supply point 12870 ~ 13860V.
- Q:With tl494 and do with UC3842 Which power is better?
- UC3842 I now do this with switching power supply
- Q:Led special power how to wiring
- After the power is connected, if the light is not bright, then the GND and 12V on the line down, if the swap is still not bright, or light burned, or the power is broken, or the line open.
- Q:Do you want to use the DC24V of the alarm system for the power cord of the bus-specific fire-fighting telephone?
- 2, when the current use of fire telephone module access, the module itself needs to provide DC24V power supply, power supply by the fire alarm controller output power bus. The fire telephone module, respectively, access to the power bus, telephone bus (fire phone controller output), and output two bus access to the phone jack and telephone extension.
- Q:Driving recorder dedicated power box for what use
- 1) Driving recorder is through the recorder comes with the adapter plug in the car cigarette lighter interface, the use of the process of driving; 2) After the recorder to be charged to charge, then connected to a USB port with a USB or USB charger on the charge can be;
- Q:Industrial instrument power supply with a good switching power supply or transformer
- Upstairs brother who understand the wrong, 1: switching power supply unless it is more expensive resonant switching power supply, or its interference than the general composition of the transformer circuit should be large, you look at the high-end audio Why not switch power ( There are special, open-loop resonant) 2: switching power supply so-called "anti-lightning) is only one or two varistors connected in parallel at the input, anti-lightning that is what way to see the lightning, the function is limited, this and the transformer The difference is not large, the transformer and the post-pole regulator circuit .3 transformer output voltage for the exchange, want to get a stable DC voltage output must be added to the circuit, so the regulator is more stable depends on your components and circuits, not switching power supply It must be better than the transformer. I would like to say that the transformer is better than the switching power supply, but each has its own advantages and disadvantages, for the general instrument, I still recommend the use of genuine switching power supply, if it is very sensitive instrument, it is optional transformer circuit, or you will find There is interference.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Sapphire Single-phase Power Frequency Furnace Heating Power Supply
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 50 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches