Sapphire Single-phase Power Frequency Furnace Heating Power Supply
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 50 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application Scope
Sapphire single-phase power frequency furnace heating power supply is mainly for the gem furnace which needs of single-phase AC power supply. The product can provide power output with high precision and reliability for the sapphire furnace production process, so as to ensure temperature stability of the sapphire crystal process.
Product Principle
It adopts transformers primary lateral pressure regulating and secondary lateral voltage reducing. Use transformer primary side and secondary side voltage regulator voltage output. With double closed loop control in the whole process, the output voltage is of high precision and high reliability.
Technical Features:
1. Flexible operation and convenient maintenance: It installs LCD (Liquid Crystal Display) monitor panel and displays operation parameters in real time. The control parameters can be modified online and fault information can be automatically recorded, etc.
2. High control accuracy and good stability: It adopts phase-locked loop synchronous circuit and 16-bit digital trigger. It does voltage and current sampling by True-RMS calculation chip. It is designed of multiple software protection function for overvoltage, overcurrent, overheating, feedback disconnection and lack of phase alarm etc. The power devices and circuit breaker etc. adopt international and domestic famous brands.
3. Advanced processing technology of transformer: Transformer adopts high-low pressure complete foil coil winding, step laminated and damping measures. It is with merits of low noise and loss, light weight with small volume, and saving installation space. It has strong heat dissipation ability to achieve 20% overload running stably under the condition of forced air cooling.
4. Digital communication control:It control the output power of power supply cabinet through the MODBUS communication mode and read the real value of output voltage, current and fault type, etc.
Main Technical Parameters
AC Input | Input voltage | AC380V±10% |
Input current | 300A | |
Working frequency | 50(60>Hz±5% | |
AC Output | Output Voltage | 0 〜15V |
Stable-voltage precision | <1%o< span=""> | |
Current | 0-8000A | |
Overload capacity | 1.1*In | |
Main characteristics | Work mode | cv |
Type of cooling | Wind cooling | |
Protection | Input phase-deficient | Input A、B、C three- phase, lose phase cause stop |
Output overvoltage、over current | Over threshold cause stop | |
Environment temperature | 5~40℃ | |
Ambient humidity | 0 〜85% No condensation | |
Altitude | ≤1200m | |
Dimension | (HxWxD) Size | 2050 x 820 x 1750 mm |
Weight | 1000Kg |
- Q: Power for ups power supply which well-known imported brands
- PROTEK US original imported power dedicated models, good quality, the price is not cheap.
- Q: EPS emergency power supply and DC screen is one thing, what is the difference between the two?
- DC screen [1] is a short description of the DC power supply operating system. Universal name for the intelligent maintenance-free DC power supply screen, referred to as DC screen, universal model for the GZDW. Simply put, the DC screen is to provide a stable DC power supply equipment. (Directly converted to DC220V or DC110V when inputting 380V power supply, and input directly to battery power when input (mains and standby) are input - DC 220V or DC110V: it can be said to be an industry Dedicated emergency power supply). Power plants and substations in the power of power supply are now used in DC power supply, which for the control load and power load and DC accident lighting load to provide power, is the basis of contemporary power system control and protection. The DC screen is composed of crossover power unit, charging module unit, step-down silicon chain unit, DC feed unit, power distribution monitoring unit, monitoring module unit and insulation monitoring unit. It is mainly used in small power plants, hydropower stations, substations, and other users of DC equipment (such as petrochemical, mining, railway, etc.) for power substation and sub-circuit. Electrical protection and fault lighting and other occasions.
- Q: Industrial electricity in the DPS.UPS, etc. are temporary power to Caesar ah
- and some can delay a few minutes, some can be delayed for several hours, but if the request for a few days that can not be achieved, Only when the temporary power supply
- Q: Industrial plant design 10 kV substation from the power supply to the client side, such as mechanical equipment, such as the overall structure of the connection diagram
- the first part of the transmission section, transmission start, transmission How long the line, how much transmission voltage, how much capacity to transport, what kind of bar-type selection, etc.,
- Q: Apple 4s dedicated mobile power are what?
- 5) to see product charge management, 6) see compatibility, 7) to see the characteristics of the product features, 8) to determine the positioning of the purchase of products, 9) Note the weight of the product.
- Q: Industrial 380 inverter how to enter the home 220 power supply work
- This is not the normal use of the. Can only say that you use the step-up isolation transformer 220V into a single-phase 380V power supply to the inverter, the inverter can only display, can not be normal with the motor
- Q: Industrial electricity (380V) what the color of the wire, which is the line of fire, which is the zero line
- 380 three-phase four-wire, yellow green red on behalf of ABC three FireWire, zero line is generally blue or black, ground line is yellow and green line
- Q: What is the best industrial power industry?
- Under normal circumstances, Chaoyang power supply accuracy, ripple factor, can meet the industrial use
- Q: What is the difference between computer power and industrial switching power supply?
- No difference, but the power is not the same, use is not the same
- Q: Industrial power cabinet generally use what brand of power
- 3.APC, the old brand, was EMERSON acquisition, but the market share and then gradually reduced.
Send your message to us
Sapphire Single-phase Power Frequency Furnace Heating Power Supply
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 50 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches