Frequency Drive for 3 Phase 0.4kw AC Variable
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
ac variable frequency drive for 3 phase water pump and blower with best quality and price
Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter
1. Voltage class: 380V
2. Range of power: 0.4KW~450KW
3. Stable and reliable Control Mode
(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.
(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.
Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.
(3) Torque control: Fast torque response,<20ms, precision torque: <5%, applied to winding, drawing and other occasions.
Technical Parameter
VFD Capacity | Input Voltage (V) | Power Capacity (KVA) | Input Current (A) | Output Current (A) | Adapter Motor(KW) |
0.4T4B | 3 Phase 380V Range:-15%~20% | 1.0 | 2.4 | 3 | 0.4 |
0.75T4B | 1.5 | 3.4 | 4 | 0.75 | |
1.5T4B | 3.0 | 5.0 | 5 | 1.5 | |
2.2T4B | 4.0 | 5.8 | 6 | 2.2 |
Model Size
VFD Model | W1 | H1 | W | D | H | Installation Aperture | Weight (Kg) |
SVF-G7-G0.4T4B | 96 | 190 | 105 | 154 | 200 | Φ4 | 2.2 |
SVF-G7-G0.75T4B | |||||||
SVF-G7-G1.5T4B | |||||||
SVF-G7-G2.2T4B |
Trade terms
a. Delivery term
We will delivery for you after you done the full payment within 3 to 15 working days.
b. Payment
For small order by air or by express, it is 100% T/T in advance.
For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.
c. Packing
Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.
- Q: How to choose the right inverter?
- 2, constant torque load Constant torque load equipment requires low frequency inverter torque, dynamic response speed. Inverter 0HZ vector state, to 150% of the torque, to meet the needs of various conditions. For example: a dredger owner bucket inverter system, is a constant torque load, dual motor, and the load overload time is long, so the inverter configuration configuration to enlarge the two models of the G-type machine, while the power supply for the device Machine power supply, the inverter must be configured to input AC reactor.
- Q: How does the laptop's power adapter open
- Notebook power adapter using the correct method] 1. Try to avoid the use of outdoor or harsh environments to prevent the adapter is exposed or damp. 2. When you are not using the adapter, please unplug the power plug. Because, for a long time the power will let the adapter has been in working condition, will affect the end of life. 3. Although the adapter is a broadband operating voltage, marked from 100V-240V can be, but if the voltage is extremely unstable in the case of use, the same will cause damage to the power adapter.
- Q: Laptop computer about electricity no electricity, is the power adapter problem?
- "The adapter light is bright" is just a matter of line between the AC power supply and the power adapter, and the power adapter to the computer that line may be bad or the computer interface is not good. Practice shows that the adapter's computer interface where the line is most likely broken
- Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
- Q: There is no inverter comes with simple PLC programming function
- The PLC is programmed to handle digital and analog, the core of the entire control system. It can output the digital to the inverter, so that the inverter is reversing, you can output the analog to the inverter set speed, but also through the communication, direct control inverter
- Q: Speed of 3000 r / min three-phase motor how to change its speed
- The key lies in two points: 1, you ask the variable range is how much? 2, your motor had a few qualifying? If your motor is 6 outlet, and you only need to speed, plus your motor is also an asynchronous motor, and you do not have the requirements of the load; then congratulations, you can achieve "speed" You just put the motor wiring way to do a △ - Y or Y - △ conversion can be achieved. If the above conditions you have one or two can not meet, then your best way is to buy a drive to achieve the variable speed. Of course, you can also make some changes to the winding to achieve the so-called single-winding multi-speed operation (this change, but the need for a certain technical content).
- Q: 18: 5 kilowatts bipolar multi-pole pump motor with inverter
- If you worry about the small, with 18.5KW is far enough.
- Q: Laptop power adapter is used to do what
- The laptop's power adapter is a device that converts 220V AC power from a power supply unit to a low-voltage direct current device for powering a laptop. Power adapter output low-voltage direct current into the computer, but also through the computer motherboard power circuit to further deal with, resulting in 1.8V, 3.3V, 5V and other sets of voltage for memory, CPU and other components to run; another power adapter to provide the power can also be related Charge control circuit to charge the battery for the laptop.
- Q: B2b frequency how to speed
- can be seen from the formula: frequency f changes, the speed will follow the change. 2) When the motor connected to the public grid, you can use the inverter (2) When the motor is connected to a single motor, you can change the output frequency of the generator directly to change the output frequency of the generator. Change the frequency of the power supply to the motor to change the speed of the motor.
- Q: The emitter E of the inverter inverter module and the AC output U are not directly connected together
- Pairs of modules are connected in a phase branch The phase output is derived from the neutral point between the modules
Send your message to us
Frequency Drive for 3 Phase 0.4kw AC Variable
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches