  ac variable frequency drive for 3 phase water pump and blower with best quality and price

Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

 

1. Voltage class: 380V

 

2. Range of power: 0.4KW~450KW

 

3. Stable and reliable Control Mode

 

(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.

 

(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.

 

(3) Torque control: Fast torque response, <20ms, precision torque: <5%, applied to winding, drawing and other occasions.

Technical Parameter

VFD Capacity

Input Voltage (V)

Power Capacity (KVA)

Input Current (A)

Output Current (A)

Adapter Motor(KW)

0.4T4B

3 Phase 380V Range:-15%~20%

1.0

2.4

3

0.4

0.75T4B

1.5

3.4

4

0.75

1.5T4B

3.0

5.0

5

1.5

2.2T4B

4.0

5.8

6

2.2

 

Model Size

VFD Model

W1

H1

W

D

H

Installation Aperture  

Weight (Kg)

SVF-G7-G0.4T4B

96

190

105

154

200

Φ4

2.2

SVF-G7-G0.75T4B

SVF-G7-G1.5T4B

SVF-G7-G2.2T4B

Factory Overview

frequency drive for 3 phase  0.4kw ac driver.JPG

Trade terms

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.

frequency drive for 3 phase  0.4kw ac driver

Q: 380V motor addition to the inverter, but also how to change its speed?
1. Change the number of pole pairs of the motor. (Multi-pole motor use) 2. Use the frequency converter to change the frequency
Q: 3.7KW inverter with 2.2KW 6-pole motor running to see the inverter shows the current is more than 4A, with the amount of clamp to 2.8A
2, upstairs brothers to answer the correct, the basic frequency is the following constant speed torque control, load changes little, the current change is not large.
Q: My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
Motor current when the current 10A this has no effect on you, the rated current is 31.4A, your inverter is selected how many W, is the fan pump type or universal? Now the motor operating current reached 34-35A, more than the rated current, then the motor may have two problems, one is the motor leakage powerful, and in a motor is overload, resulting in increased current
Q: Yaskawa inverter reported base blockade what is the reason?
This is the base block command, when the external input block command signal, the inverter will appear this code, the code appears, the motor will be free to rotate, does not affect the use.
Q: What is the frequency of `30 points
frequency conversion By changing the AC frequency of the way to achieve AC power control technology is called frequency conversion technology
Q: Inverter problem
(0 ~ 20mA), but the main input / output is completely isolated, than the output of the inverter simulation of the output of the analog output The amount of signal impact resistance, anti-interference ability.
Q: Three-phase motor, quadrupole asynchronous motor to 15rpm, the inverter output how many volt voltage? The 4 V
The voltage is basically the same, the inverter changes the frequency of the power supply, not the voltage.
Q: What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
First of all you have to understand the difference between variable frequency motor and ordinary asynchronous motor. 1, inverter motor cooling fan is not connected with the motor spindle, is independent, the fan rotation from the motor speed, to ensure that the motor cooling.
Q: Will the laptop's power adapter is not the original good?
Theoretically can be inserted into the use and will not have any obvious damage to the machine But it is best to buy the number of volt and your original consistent Original also has original benefits According to some "professional" sources claim that no original touchpad will have a slight jitter, I was not found
Q: Delta inverter reported CE4 reasons? Casually asked how many kinds of CE under a total
Is it right? The next manual to see do not understand

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords