FB1 Stainless steel Water Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Product Introduction:
ZX series self-priming centrifugal pump falls into the category of self-priming centrifugal pump,which has such advantages as compact structure, easy operation, stable running, easy maintenance, high efficiency, long life and strong self-priming capacity. The bottom valve needn't be mounte in the pipeline. It 's only necessary to reserve a fixed quantity of guide liquid in the pump body before work. Therefore, it simplifies the pipeline system and also improves the labor conditions
2. Range of Application:
1) It is applicable for city environmental protection, building, fire control,chemical engeering,pharmacy,dyestuff,printing and dyeing, brewage, electricity, electroplating, paper making ,petroleum, mine, equipment cooling, tanker discharging,etc.
2) It is applicable for clear water, seawater, liquid containing acid or alkali chemical medium, and generally pasty slurry (medium viscosity≤100cP and solid content less than 30%).
3) When it's mouted with an arm sprayer, it can jet the water into the air to disperse into little raindrops for spraying , so it is a good tool for farm, nursery, orchar and tea garden.
4) It can work with any types and specifications of filter press, so it is an ideal type to deliver the slurry to the filter for the filter pressing.
3. Type Designation:
50 ZX 12.5-50 PB
50 Suction inlet diameter(mm)
ZX Self-priming pump
12.5 Rated flow (m3/h)
50 Lift head (m)
P Stainless steel
B Explosion-proof
4. Technology Parameters:
Flow3-280m3/h
Head12-80m
Power1.5-90kw
Ratary speed14502900r/min
32-200mm
Medium Temperature≤80
Self-priming high3.5-4.5m.
5. FAQ
1). Can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
2). Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
3). How long is your warranty?
Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice
- Q: Must the water pump in the tank be all soaked in water?
- Need a submersible pump in the water, but it is not entirely like this, I have to work for a long time no problem in water, but there is a problem you should pay attention to the water pump, at least in half, or stop when the smoke is not on water.
- Q: What are the characteristics of a pipe shield pump?
- Four, high melting point in the pump hydraulic side and the motor side with a jacket, the jacket can be steam or a certain temperature of liquid to prevent high melting liquid crystallization. The outer circulation pipe of the pump should also be insulated (heating) jacket. Five, high pressure shielding pump shell is a high pressure container, so that the pump can withstand high system pressure. In order to support the shield under internal high pressure, the stator coil itself can be used to bear the pressure. Can also be made in high temperature and high pressure under the operation of the canned pump. Six, since the suction port of the pump impeller center is much higher than that in stopping the pump, when inhaled NO liquid in the tube, the impeller and the increase of the pump chamber is filled with liquid, and then start without irrigation, the pump can work. Self-priming pumps are especially suited for extracting liquids from underground containers. In addition, according to different methods can be divided into liquid type, mud type, high pressure pipeline type, as well as for ships, nuclear power plants and absorption refrigeration devices for various types of canned pumps. Can also be divided into vertical, horizontal, online and single-stage, multi-level and other different types.
- Q: What are the functions of a disposable infusion pump?
- When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
- Q: The distance from the pump button to the ground
- After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
- Q: How is the pump level of submersible sewage pump determined?
- Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
- Q: Why is the flow of the pump too small will occur cavitation phenomenon?
- Why is it easy to produce cavitation when the inlet flow of pump is lowered?This is because the main performance parameters such as the head, power and efficiency of the centrifugal pump are not fixed, but vary with the flow rate. The curve drawn on a coordinate paper is called the performance curve or characteristic curve of the centrifugal pump. What happens when the flow rate decreases? The disadvantage of throttling adjustment is that the pump flow is small, and the impeller is easy to cause cavitation
- Q: The working principle of magnetic pump
- Magnetic pumpBy the pump magnetic pump, magnetic actuators, motors of three parts. The key components of magnetic actuator by the external magnetic rotor sleeve, inner magnetic rotor and non magnetic components. When the motor drives the outer magnetic rotor, the magnetic field can penetrate the air gap and non-magnetic material, driven by the inner magnetic rotor is connected with the impeller for synchronization the rotation, to achieve non-contact power transmission, the dynamic seal into static seal. As the shaft, the rotor is within a magnetic pump, isolated sets of completely closed to completely solve the problem of "run, run, drip, leak, remove the oil refining chemical industry flammable, explosive, toxic and harmful media through the pump seal leakage security risks, effectively ensure the health and safety of workers.
- Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
- The valve opening pump is aimed at the centrifugal pump.From the power curve of the centrifugal pump, the power of the centrifugal pump increases with the increase of the flow rate; the flow curve of the centrifugal pump shows that the flow rate of the centrifugal pump decreases with the increase of the head.
- Q: What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
- You're talking about a centrifugal pump. His series says the number of slices of the impeller (excluding the wheel, that is, the wheel)
Send your message to us
FB1 Stainless steel Water Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords