• Electric Jocky Water Pump for Firefighting Application System 1
  • Electric Jocky Water Pump for Firefighting Application System 2
  • Electric Jocky Water Pump for Firefighting Application System 3
Electric Jocky Water Pump for Firefighting Application

Electric Jocky Water Pump for Firefighting Application

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                   Electric Jocky Water Pump for Firefighting Application

 

1.Structure of Electric Jocky Water Pump

 

Vertical End Suction Inline Water Pump Type ISG, ISW Fire Pump adopts special combination structure design. They are generally applied to transport pure water or the liquids with physical and chemical properties similar to pure water, and themaximum allowed medium temperature is 80C. Especially suitable for pressurization of water supply network.The advantages are small size,easy installation,no vibration and low noise.The shaft sealingadopts mechanical seal. Type IRG pump can transport liquids of Maximum 120C. Type IHG pump could be used inchemical process type ISW pump is horizontal.

 

2.Main Features of the Electric Jocky Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

•Parallel connection and have many models to be chosen for difference flow rate and head

•Horizontally and vertically installation as different pipeline system

3.Electric Jocky Water Pump images

Electric Jocky Water Pump for Firefighting Application

4.Electric Jocky Water Pump Specification

Item

Fire Pump

Fire Pump

Single Stage Single Suction Pipeline Fire Pump

Model

ISG ISW

Material

Cast iron

Color

Blue

Mode

Horizontal

Theory

Centrifugal Pump

Structure

Single-stage Pump

Usage

Water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Gasoline

Pressure

Low Pressure

Application

Clean Water

Outlet Diameter

25-500mm

Capacity

1.1-720m3/h

Head

8-150m

Rotation Speed

1450-2900 r/min

Power

0.37-160kW

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: How does the centrifugal pump pump and cut the pump?
Turn on the motor, observe the motor current, turn from high to low, observe the pump outlet pressure, and the pressure rise;Slowly open the outlet valve, so that the pressure drop slowly, the current slowly rising to the stable, the outlet valve to the maximum;Check the pump operation, stuffing box leakage, current, whether or not the rated current, motor, bearing temperature is normal, whether or not abnormal sound.
Q: What does "anti pump" mean in pump operation?
Function: anti pump effect when used for pumping concrete pumping occurs overpressure, the pumping pressure is above 25MPA, the concrete conveying pipe out of ash, can be understood as the precursor of pipe blockage, at this time should immediately use the anti pump, the concrete from the conveying pipe in the suction into the hopper, thus preventing plugging happen
Q: Brief description of centrifugal pump on / off operation
Two, centrifugal pump start(1) the pump entrance valve fully open, start motor, outlet valve fully closed, fully check operation of pump.(2) when the pump outlet pressure is higher than the operation pressure, the outlet valve is gradually opened to control the flow and pressure of the pump.(3) check whether the motor current is within the rated value, such as the pump in the rated flow operation, and the motor overload should stop the pump inspection.
Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
(4) before installation, make sure all pipes connected with the pump should be clean, and no solid foreign bodies which may cause damage to the pump shall be allowed.(5) apply the blind flange or other things to the suction, exhaust or open pump to ensure that no sundries enter the pump cavity during the installation.(6) check whether the pump random data is complete and complete; whether the pump surface has obvious damage. Only with complete data, no obvious damage to the pump, you can continue to install.(7) the installation of centrifugal pump with the coupling of the hand when turning slowly rotating coupling or pulley, observe the pump rotation are stable, flexible and adjustable, the rotor parts have no jamming, the pump has no debris crash, bearing the operation is normal, with elastic suitability.
Q: What are the characteristics of a vertical multistage centrifugal pump?
Vertical multistage centrifugal pump system using the latest international advanced IS type hydraulic model based design for high efficiency centrifugal pump with multi segment, the soft packing or mechanical seal, has the characteristics of high efficiency, large flow, high lift, no leakage, a wide range of performance, safe operation, stable operation and long service life and small area.
Q: Water pump does not produce water, what are the reasons?
1 check whether the motor is reversed.2, to see whether the export, the entrance blocked, the outlet pressure gauge whether there is pressure.3, whether the pump selection is wrong, you can not suck up the water.
Q: How can I buy a pump?
3 、 mechanical requirements of high reliability, low noise, vibration.4, the correct calculation of pump procurement costs, the pump manufacturer to inspect, requiring good quality equipment, good after-sales service, spare parts can be timely supply.The micro pump and the motive of the mechanical energy or other external energy transmitted to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.The technical parameters of pump performance include flow, suction, lift, shaft power, water power, efficiency and so on.
Q: Is the flow meter in front of the pump or after the pump?
Agree upstairs. Pump should be straight before the paragraph, 15 times the nominal length of the caliber.
Q: What are the differences between the sewage pump and the clean water pump?
2. in order to prevent the wound, water pump impeller design is more simple but not ring pump, equipped with tips, cloth and other debris can be crushed after the pump, and the impeller water pump is relatively complex, but the efficiency will be significantly higher than the former.Why can't the sewage water pump and impeller: because features of key design, resulting in water pump for sewage situation is likely to occur, blocking, winding, wear and corrosion occurs, resulting in damage to pump or scrapped, so water pump can not be used for sewage.
Q: What are the failures and causes of the replacement of the fuel pump assembly?
Failure cause:1) the gasoline pump is too thick with the gasket at the junction of the axle box.2) pump film rupture or pump film and pump shell combination of sealing is not strict.3) the oil inlet valve is stuck or sealed badly.4) severe wear of the rocker arm, reducing the pump film stroke.5) the pipeline from the gasoline tank to the gasoline pump is not smooth, or the pump film spring passes.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords