Features of Low Frequency Transformer EI Series
1. input:AC110V-250V 50-60Hz
2. Output:AC 3.0-800V
3. Modle:: EI series
4. CE,ROHS compliant, products are applying for CQC and ISO9001
Application of Low Frequency Transformer EI Series:
Home electronic appliances, communication instruments, medical apparatus, power tools, message armchairs and air-condition.
Common Electrical Paramenters
Specification
1. machine- inserted silicon steel with fire relardation
2. Flame Retardant Nylon Bobbin3
3. equipment: 3 EI type transformer lines, 4 sets of vacuum annealing furnaces
Normal EI Pin Transformer Specifications
Item | Core type | Output power(w) | Item | Core type | Output power(w) |
EI28 | EI28/8×12 | 0.5-1 | EI57 | EI57/19×30 | 16-32 |
EI28 | EI28/8×16 | 0.7-1 | EI57 | EI57/19×38 | 20-40 |
EI35 | EI35/9.6×10 | 0.2-0.8 | EI66 | EI66/22×22 | 17-35 |
EI35 | EI35/9.6×12.5 | 0.25-1 | EI66 | EI66/22×28 | 24-45 |
EI35 | EI35/9.6×16 | 0.4-1.7 | EI66 | EI66/22×35 | 36-58 |
EI35 | EI35/9.6×20 | 0.6-2.5 | EI66 | EI66/22×45 | 55-77 |
EI41 | EI41/13×13 | 0.6-2.3 | EI76 | EI76.2/25.4×25 | 65-88 |
EI41 | EI41/13×16 | 1-3.6 | EI76 | EI76.2/25.4×31.5 | 71-95 |
EI41 | EI41/13×21 | 1.6-5.5 | EI76 | EI76.2/25.4×40 | 70-97 |
EI41 | EI41/13×26 | 2.3-7.7 | EI76 | EI76.2/25.4×50 | 86-123 |
EI48 | EI48/16×16 | 2-5 | EI85.8 | EI85.8/28.6×29 | 70-95 |
EI48 | EI48/16×20 | 2.8-7.2 | EI85.8 | EI85.8/28.6×36 | 84-120 |
EI48 | EI48/16×25 | 4.6-11.1 | EI85.8 | EI85.8/28.6×46 | 105-154 |
EI48 | EI48/16×32 | 7-10 | EI85.8 | EI85.8/28.6×58 | 130-200 |
EI54 | EI54/18×18 | 5-12 | EI96 | EI96/32×40 | 100-150 |
EI54 | EI54/18×22.5 | 8-17 | EI96 | EI96/32×45 | 110-160 |
EI54 | EI54/18×29 | 11-25 | EI105 | EI105/35 | 500-700 |
EI54 | EI54/18×36 | 17-34 | EI114 | EI114/38 | 700-1000 |
EI57 | EI57/19×19 | 7-16 | All the output voltage and current are according to customers requirements. | ||
EI57 | EI57/19×24 | 14-21 |
- Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
- The sectional area of the wire can be calculated according to the electric power formula. The current required by the wire is calculated, and then the reference to the national standard "500 volt copper core insulated wire, long term continuous load allowable ampacity meter" is selected.
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
- Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
- Q:Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q:Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q:What's the function of the lighting transformer?
- In addition, can be rated power supply voltage of not more than 1000V AC circuit, as a machine tool and mechanical equipment control power, work lighting and signal light power supply, can also be used as a small power supply!
- Q:How many power illuminator can 5Kva 36V transformer drive?
- The load capacity of the transformer is 70% of its nominal power, so it is concluded that the transformer you provide can drive the 3.5KVA 36V lighting appliance (which is used in normal condition and environment)
- Q:Why is elevator lighting transformer installed?
- Is that the kind of 220V change 36V ah, if it is that kind of thing, I think it should be for security reasons. After all, 36V is a safe voltage. The damage to humans is slightly smaller than that of 220V.
- Q:How to calculate the rated capacity of small transformers for lighting purposes?
- In view of the power [kVA] conversion of each load, multiplied by the amount of consumption, according to the importance of the load, equipment location, voltage statistics, set the load line and load place of plastic case transformer capacity and its connection position. The future load power equipment shall be judged on the basis of prior installation or consideration of the economy in terms of equipment addition, installation, etc..
1. Manufacturer Overview |
|
---|---|
Location | Tianjin,China |
Year Established | 2002 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 18.00% North America 15.00% South America 13.00% Africa 13.00% Eastern Europe 5.00% South Asia 5.00% Central America 5.00% Western Europe 5.00% Eastern Asia 5.00% Mid East 5.00% Oceania 5.00% Southeast Asia 3.00% Southern Europe 3.00% Northern Europe |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Tianjin Port |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b)Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Low Frequency Transformer EI Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords