EI Type Low Frequency Transformer Products
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features Of EI Type Low Frequency Transformer
1. input:AC110V-250V 50-60Hz
2. Output:AC 3.0-800V
3. Modle:: EI series
4. CE,ROHS compliant, products are applying for CQC and ISO9001
Application of EI Type Low Frequency Transformer:
Home electronic appliances, communication instruments, medical apparatus, power tools, message armchairs and air-condition.
Common Electrical Paramenters
Specification of EI Type Low Frequency Transformer
1. machine- inserted silicon steel with fire relardation
2. Flame Retardant Nylon Bobbin3
3. equipment: 3 EI type transformer lines, 4 sets of vacuum annealing furnaces
Normal EI Pin Transformer Specifications
Item | Core type | Output power(w) | Item | Core type | Output power(w) |
EI28 | EI28/8×12 | 0.5-1 | EI57 | EI57/19×30 | 16-32 |
EI28 | EI28/8×16 | 0.7-1 | EI57 | EI57/19×38 | 20-40 |
EI35 | EI35/9.6×10 | 0.2-0.8 | EI66 | EI66/22×22 | 17-35 |
EI35 | EI35/9.6×12.5 | 0.25-1 | EI66 | EI66/22×28 | 24-45 |
EI35 | EI35/9.6×16 | 0.4-1.7 | EI66 | EI66/22×35 | 36-58 |
EI35 | EI35/9.6×20 | 0.6-2.5 | EI66 | EI66/22×45 | 55-77 |
EI41 | EI41/13×13 | 0.6-2.3 | EI76 | EI76.2/25.4×25 | 65-88 |
EI41 | EI41/13×16 | 1-3.6 | EI76 | EI76.2/25.4×31.5 | 71-95 |
EI41 | EI41/13×21 | 1.6-5.5 | EI76 | EI76.2/25.4×40 | 70-97 |
EI41 | EI41/13×26 | 2.3-7.7 | EI76 | EI76.2/25.4×50 | 86-123 |
EI48 | EI48/16×16 | 2-5 | EI85.8 | EI85.8/28.6×29 | 70-95 |
EI48 | EI48/16×20 | 2.8-7.2 | EI85.8 | EI85.8/28.6×36 | 84-120 |
EI48 | EI48/16×25 | 4.6-11.1 | EI85.8 | EI85.8/28.6×46 | 105-154 |
EI48 | EI48/16×32 | 7-10 | EI85.8 | EI85.8/28.6×58 | 130-200 |
EI54 | EI54/18×18 | 5-12 | EI96 | EI96/32×40 | 100-150 |
EI54 | EI54/18×22.5 | 8-17 | EI96 | EI96/32×45 | 110-160 |
EI54 | EI54/18×29 | 11-25 | EI105 | EI105/35 | 500-700 |
EI54 | EI54/18×36 | 17-34 | EI114 | EI114/38 | 700-1000 |
EI57 | EI57/19×19 | 7-16 | All the output voltage and current are according to customers requirements. | ||
EI57 | EI57/19×24 | 14-21 |
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
- Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
- How many transformers should be used in the lighting of the 36V transformer, which should be chosen according to the power required. The greater the load (power), the greater the power to select the transformer.
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: Is the substation separate from the power and illumination transformer?
- There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage
- Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
- 220V500W more power saving:Reasons: 1, high voltage, small current, line loss is small; 2, reduce the transformer and other intermediate links, each link has a loss.
- Q: Power and lighting transformers, lighting quality will be affected much?
- First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
- Q: Why can't autotransformer be used as transformer for safety lighting?
- The transformer of the lighting circuit is a step-down transformer (general input 10kv., 220V). The first coil of the autotransformer is shared and connected together
1. Manufacturer Overview
Location | Tianjin,China |
Year Established | 2002 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 18.00% North America 15.00% South America 13.00% Africa 13.00% Eastern Europe 5.00% South Asia 5.00% Central America 5.00% Western Europe 5.00% Eastern Asia 5.00% Mid East 5.00% Oceania 5.00% Southeast Asia 3.00% Southern Europe 3.00% Northern Europe |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin Port |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
EI Type Low Frequency Transformer Products
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches