E.G. Iron Wire For Binding
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Galvanized Iron Wire /Galvanised Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: so im lost in how i should wire my subs. I have two subs that i need to wire both are 2 ohms 400 watts i don't know if i should wire them parallel or series if you can help me out that would be great!
- usually all sub wiring is the same, youll have the rca cables and antenna wire comming from the radio to the amp, power and ground wire going from amp to battery and ground, and than should have 2 wires coming off each sub to the amp, im guessing thatd be parallel, if you wire in series, so like use 2 wires and splice off to each sub, so 2 wires off the amp powering each sub you would up the ohms and put a too much of a load on the amp, people only wire in series when they have too many subs and not enough outlets on the amp, good luck
- Q: So ground wire, start anywhere i suppose?Where does ground wire hook up too?why you need to ground out your system?Only need 1 ground wire?
- The ground wire in an automobile accessory installation is to make the complete circuit for the electricity to follow. Some things on cars use the frame and metal panels for grounding, but for an amp and some radios you probably should not. The battery is grounded to the frame and to the engine.
- Q: Which wire is quot;hot, white or black?
- There is no code required or generally accepted color code for fire alarm wiring. Usually circuits for different purposes are color coded differently. For instance, initiating device circuits and notification appliance circuits.
- Q: Or can stranded wire of the same gauge be subsitituted for solid wire without any consequences? The reason I ask is because its for a massive 4kJ capacitor discharge circuit, and I need all the energy delivered to the power coils im using, cant afford to have much leakage inductance.
- You question about Inductance seems illogical. I can't imagine how a straight wire will affect a sudden discharge of current unless the wire is coiled (inductor) or have a shield attached to ground(capacitor). I believe the difference between the two wires are their direct current resistance which is very negligible if the wires are just a few feet long. The Capacitor that will discharge current directly to a coil is a 'tank circuit' and is a type of oscillator. Most likely, The inductance you will experience is caused by the power coil itself that feeds it back to the capacitor and vise versa. If that is true, I recommend a reverse shunt diode across the coil and a series diode between the capacitor and the coil.
- Q: I have a proj in tle class about solid wire joints and splices and i cant find a picture of 18 of the splices / joints we did at school we needed to like insulate the wires and twist em with each other help!
- Electrical Splices And Joints Pictures
- Q: the charger has three wires to put a male plug on and they are black white and green and they look like 12 gauge wires
- wire colors are green is ground the black and white wires are you load wires look at you 240 volt plug and determine which terminal is the ground this one is where the green wire goes the black and white wire go to other two terminals this should do it
- Q: Im wondering if this 24 awg wire is good for guitar wiring. Doesn't look like something that i usually would see people use when wiring, since there is lots of different wires and colour coding wrapped up inside it.
- Given okorder / I hope this will help with your decision. Good luck!
- Q: I currently have a ceiling fan wired to a dimmer wall switch that controls the fan and the light, not good I know. I would like to set up the dimmer switch where it controls the light only and then i can use the fan pull switch for the fan. but i am not sure how to wire this with my current wires. In the wall box where the dimmer switch is I have two sets of wires coming from two different locations. one set has a black, red, white, and green. the other location has black, white and copper. currently the green and copper are connected and capped, the two whites are connected together and capped, two blacks are and connected to the black wire coming from the dimmer and the red is connected to the other black wire from the dimmer. how would I wire the dimmer switch to only control the light and not the fan? I want to make sure i do this safely.any assistance is greatly appreciated.
- enable me initiate out by making use of asserting that the cord's popping out of the ceiling bypass like this, Black cord is alway the warm cord the White cord is often the common floor cord the bare cord is the earth floor cord. if there's a purple cord popping out of the ceiling it is so which you would be able to turn the mild off at extra then one change . i'm uncertain what a hunter fan is ,yet what ever you do do no longer hook the black (warm) cord with the WHITE (floor) cord, in case you probably did try this ,you will could reset your breaker , it form of seems such as you may have 2 purple cord popping out of the ceiling , in case you do you may hook them to the Black / White cord, it is so which you would be able to paintings the mild from the two change.
- Q: I just tore my old shed down, that was wired for electrical. though I never used power out there There is size 10 wiring (two wires), running from the house to where my shed was. I then bought a Tough Shed from The Home Depot and put it where my old shed was. While working on wiring my new shed for electricity, I turned power off to the entire house.I am trying to install power to the shed and I spliced the size 10 wires to size 14 (three cable, includes a ground) which I have connect to an electrical outlet in the shed, but once I turn the main power box back on, the circuit that runs power to the shed keeps tripping off. Am I missing something here?Thanks
- Open the splices and leave the size 10 wires unattached with wire nuts over them. Try to power up the wires when they are disconnected. If it doesn't trip, you must have reversed your wiring. If it trips, the wires are shorted to ground. Perhaps the wires are rotted out under ground or grounded by a sharp metal edge. The shed curcuit breaker should be changed to a 15 amp if you will splice to 14 gauge. Or: There should be a breaker box like there was in the old shed, with 15 amp breakers for for 14 wire. 20 amp for # 12 wire.
- Q: I want two lights on two 3-way switches.1. Power from basement box into light #1 with 12-2 wire. 2. Another 12-2 wire from light #1 to light #2.3. A 12-3 wire from light #1 to switch #1.4. Another 12-3 wire from light #2 to switch #2. Will this do it?
- nevermind what I think....the guy under me knows EXACTLY what he is talking about! Do it exactly like he says. His way is better than mine was, honestly, because he has more experience. Thats why I deleted my own answer----we call that professional courtesy to seniority and its what electricians do when someone has more experience than we have speaks up. Now it doesnt matter what I think....I only have 22 years experience and someone with more experience than I has given better, sounder advice than I did. You should listen to him, not me.......or anybody else whom cannot match or exceed his experience. Or didnt you know that all Electricians are part of the same Brotherhood? This is why we always agree (or agree to be wrong). I was wrong, obviously, and my advice, second rate, compared to the advice you are about to get. So.....Pay attention! Wisdom follows!!!!
Send your message to us
E.G. Iron Wire For Binding
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords