Drainage Pump For Garden and Farm
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 35000台 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.CE certificate2.Aluminium/Stainless steel/PPO
3.Mechanical seal:Ceramic-Graphite
4.Suction strainer:Stainless steel
1'' 1.5m3/h 12v ac small electric water pump
♦APPLICATION AREA
For countryside lifting water from,water supply and
Specifications
1.CE certificate2.Aluminium/Stainless steel/PPO
3.Mechanical seal:Ceramic-Graphite
4.Suction strainer:Stainless steel
QDX 1'' 1.5m3/h 12v ac small electric water pump
♦APPLICATION AREA
For countryside lifting water from,water supply and drainage of farm and,garden,and daily life.Drainage of industry ponding,building construction and breeding.
♦OPERATING LIMITS
Trans medium'sPH:6-8.5
Fluid temperature limit:<40°C
Max ambient temperature: :<40°C
Operating depth:5m
♦STRUCTION CHARACTERISTICS
Insulation class:E
Protection class;IP68
♦FEATURES
1. CE, GS certificate
2. 100% copper wire, automatic wiring
3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and
precision.
4. CNC precision automatic lathe for smoother shaft.
5. Strict tests include water test, outgas test and performance test, ect.
6. Anti-rust treatment castings and electrophoresis.
7. 23-year experience, 1 year warranty.
Specifications
1.CE certificate2.Aluminium/Stainless steel/PPO
3.Mechanical seal:Ceramic-Graphite
4.Suction strainer:Stainless steel
QDX 1'' 1.5m3/h 12v ac small electric water pump
♦APPLICATION AREA
For countryside lifting water from,water supply and drainage of farmland,garden,and daily life.Drainage of industry ponding,building construction and breeding.
♦OPERATING LIMITS
Trans medium'sPH:6-8.5
Fluid temperature limit:<40°C
Max ambient temperature: :<40°C
Operating depth:5m
♦STRUCTION CHARACTERISTICS
Insulation class:E
Protection class;IP68
♦FEATURES
1. CE, GS certificate
2. 100% copper wire, automatic wiring
3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision.
4. CNC precision automatic lathe for smoother shaft.
5. Strict tests include water test, outgas test and performance test, ect.
6. Anti-rust treatment castings and electrophoresis.
7. 23-year experience, 1 year warranty.
♦OPERATING LIMITS
Trans medium'sPH:6-8.5
Fluid temperature limit:<40°C
Max ambient temperature: :<40°C
Operating depth:5m
♦STRUCTION CHARACTERISTICS
Insulation class:E
Protection class;IP68
♦FEATURES
1. CE, GS certificate
2. 100% copper wire, automatic wiring
3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and
precision.
4. CNC precision automatic lathe for smoother shaft.
5. Strict tests include water test, outgas test and performance test, ect.
6. Anti-rust treatment castings and electrophoresis.
7. 23-year experience, 1 year warranty.
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- (1) pump connected outside pipes, containers, pipes, joints and other leakage test instrument, large leakage, rotary gas plug exhaust sound big, and the gas and oil mist discharge, should find leakage cancellation.(2) the assembly of rubber of intake pipe is not proper, damage or aging should be adjusted or replaced.(3) plug hole, the vacuum degree can be decreased, put the oil, remove the tank, loosen the nozzle plate, pull out the oil inlet nozzle, dredge oil hole, try not to use cotton wipe parts.(4) the vacuum system has serious pollution, including containers, pipes and so on. It should be cleaned.(5) the spring of the vane is broken and should be adjusted.
- Q: What is a solution pump?
- (4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
- Q: The water tank of the fish tank does not air out and only has the water outlet
- The air inlet pipe is connected with the oxygen burst, the entrance also pulled out, we can see that it is the design of a miter, the oblique incision back to the direction of the water flow speed, this outflow, negative pressure is formed in the oblique incision, the air can be sucked in. As shown.
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm pump and centrifugal pump refer to the structure of the pump, and the vacuum pump means the use of the pump. There is no comparability between them.Centrifugal is the sign of inertia of an object. As the umbrella turns, water droplets move out of the outer edge of the umbrella and are thrown out. This is what is called centrifugal. Centrifugal pump is designed according to this principle. The high speed rotating impeller blade drives the medium to rotate and is thrown out so as to achieve the purpose of conveying.
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
- Q: What is the liquid pump? What are their categories? What are their strengths and weaknesses?
- The air driven liquid pump adopts compressed air driving method, and has the following advantages:The pressure can be adjusted by manual pressure control valve or air control valveIt is driven by air and is especially suitable for explosion protection applicationsAble to achieve pre-set final pressureAutomatic pressure relief by pumpLong term conservation without consuming energyWhen holding pressure, medium will not overheatThe utility model has the advantages of convenient installation and low maintenance cost, and only needs to connect the gas source, the inlet pipeline and the pressure pipelineReliable operation, low maintenance cost and little noise at the time of operation
- Q: Working principle and structure of external gear pump
- The principle of the gear pump, gear pump structure consists of two gear mesh together with each other, and composed of pumps known as gear pumps. It relies on the gear teeth meshing space change in volume to transport the liquid, it belongs to the rotary pump, also can be considered as a volume pump. There are many kinds of gear pumps. According to the meshing mode, it can be divided into external gear pump and internal gear pump. According to the tooth shape of gear, it can be divided into positive gear pump, helical gear pump and herringbone gear pump.
- Q: What do you mean by the self coupling device on the pump?
- Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.
- Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
- This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Send your message to us
Drainage Pump For Garden and Farm
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 35000台 unit/month
OKorder Service Pledge