• DJL Diaphragm Metering pumps With high quality System 1
  • DJL Diaphragm Metering pumps With high quality System 2
DJL Diaphragm Metering pumps With high quality

DJL Diaphragm Metering pumps With high quality

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Packaging & Delivery

Packaging Detail:Export Carton Box
Delivery Detail:7 days after received the payment

Specifications

DJL Diaphragm Metering Pump 
Widely used in petroleum, 
chemical industry, electric power, metallurgy, mining,

 

Product Description

 

Flow:0-120 lph

 

Pressure: 0-10Bar

 

Power: 60W, 50/60Hz

 

Drive System: 2 or 3 phase motor,

 

400V or 110V motor

 

Protection Degree: IP55

 

Flow Control: Manual operation

 

 

 

Material

 

Pump head: SUS304, SUS316, PVC, PTEF

 

Diaphragm: PTFE

 

Valve: SUS304, SUS316, PVC, PTEF

 

Valve ball: ZrO2, SUS304, SUS316, Ceramic

 

 

 

Work Condition

 

Envitonment temperature: -30°C --- 60°C

 

 

 

Package

 

Material: Carton

 

Measurement:36 x 25 x 30 cm

 

Gross Weight:

 

 

 

Technical Parameter

 

 

 

Model

Flow  (lph)

Pressure (Bar)

Stroke (mm)

Frequency
 (min-1)

Diaphragm Diameter  (mm)

Power (W)

Caliber (DN)

DJL10/10

10

10

3

75

60

60

6

DJL20/10

20

10

3

120

60

6

DJL40/8

40

8

4

120

60

6

DJL60/6

60

6

4

100

84

10

DJL80/5

80

5

5

100

84

10

DJL100/4

100

4

5

120

84

10

DJL120/4

120

4

5

150

84

10

 

Using reliable quality motor,380V or 220V or direct current machine is optional.

 

 

 

Features

 

1.Very high safety of operation. Mechanical actuate diaphragm. Changeable eccentric drive

 

2.Power off seal,no leakage,with security delivery device,simple maintance

 

3.It can transport high-viscosity mediums, corrosive liquid and dangerous chemical goods.

 

4.The flow can be controlled via adjusting the length of stroke or the motor frequency.

 

5.The diaghragm is made from multilayer complex structure to promote the life span, the first layer is Teflon anti-acid diaphragm, the second is EPDM stretch rubber, the third is 3.00 mm thick SUS304 that supporting the iron corn. The fourth is also the EPDM stretch rubber to cover all of the body.

 

 

 

Purpose

 

Widely used in petroleum, chemical industry, electric power, metallurgy, mining, shipbuilding,light industry, agriculture, national defense department and etc. 


Q: Piston filling and peristaltic pump filling which precision is high?
These two pumps are used as a metering pump to use, so the accuracy is to be on a par with the peristaltic pump has more advantages than the piston pump is the largest energy fluid conveying there are particles, and the piston pump is smaller than the peristaltic pump pulse, so we need to choose according to the material characteristics you need to transport.
Q: Working principle and diagram of axial piston pump with pressure compensation variable
Working principleThe main part (see section structure) the transmission shaft drives the rotating cylinder, the plunger seven uniform distribution on the cylinder to rotate around the shaft center line through the center of the spring will be slippery boots column components in the variable pressure in the head (or swash plate). In this way, with the rotation of the plunger cylinder for reciprocating motion complete, oil absorption and oil pressure action.
Q: Is the diaphragm pump and the drain pump one?
First of all, there's something wrong with your concept.Diaphragm pump is in accordance with the way the pump classification, drain pump is in accordance with the use of pumps classification.
Q: What's the difference between non negative pressure and variable frequency water pump?
No negative pressure is superposed pressure intelligent frequency conversion equipment, pump frequency operation is no negative pressure difference, and the variable frequency pump, variable frequency pump is advanced municipal tap water tank or pool, pump from the tank or pond water pressure to set pressure to the pressure water supply, and no negative pressure directly from water the municipal pipeline, using the original municipal 2~3 kilograms of pressure
Q: Excuse me, what is the water pump from the lotus root?
The pump is automatically coupled by the self coupling device to move downwards along the guide rod to the position, thereby achieving the simple and convenient effect. There's no need to jump into the septic tank when it's time to repair.When you buy a sewage pump, a professional person will ask you what kind of installation you need!
Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
Important equipment for deep well water extraction. When in use, the whole unit dives into the water. The extraction of groundwater to the surface is water, mine rescue, industrial cooling, irrigation, water lifting, ship ballast, also can be used in fountain landscape, hot water submersible pump for hot spring bath, but also can be applied to the extraction of groundwater from wells, can also be used in rivers, reservoirs, canals and other water projects. The utility model is mainly used for farmland irrigation and water for human and livestock in mountain areas, and can also be used for central air conditioning cooling, heat pump units, cold pump units, cities, factories, railways, mines and site drainage. General flow can reach (10m3~650m3) per hour, head up to 1500 meters.
Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
1., consciously abide by the traffic control department management rules, to achieve civilized driving, safe driving.2. responsible for the daily maintenance, cleaning and cleaning of the pump truck, and ensure the equipment is in good condition.
Q: The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q: Why is the sewage pump device coupler?
Advantages of installation and arrangement of sewage pump coupling:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device under the condition of fixed installation, such as pump fault maintenance personnel need to unscrew the screw pump lifting water, repair, or other small pump to pump the water down perfect maintenance, if the water is dirty, it would be difficult for people to go to the next, then the overhaul had great difficulty.
Q: What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords