Different Gauges Dark Annealed Wires with High Resistance
- Loading Port:
- Tianjin
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m.t
- Supply Capability:
- 10000 m.t/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Different Gauges Dark Annealed Wires with High Resistance
1. Structure of Different Gauges Dark Annealed Wires with High Resistance Description:
Different Gauges Dark Annealed Wires with High Resistance is very good for Chain link fence, fencing mesh, gabion mesh box production and for construction business as tire wire, binding wire and galvanized wire raw material production.
Different Gauges Dark Annealed Wires with High Resistance is mainly processed into coil wire, spool wire or big package wire. Annealed wire is used as tie wire or baling wire in building, parks and daily binding. Besides, black annealed wire is mainly used as industrial wire, construction wire, industrial bale tie wire and constructional tie wire, etc.
2. Main Features of Different Gauges Dark Annealed Wires with High Resistance:
• Durable
• Practical
• Versatile
• Use widely
• Inexpensive
• High Quality & Reasonable Price
3. Different Gauges Dark Annealed Wires with High Resistance Images
4. Different Gauges Dark Annealed Wires with High Resistance Specification
5. FAQ
We have organized several common questions for our clients,may help you sincerely:
① How about your products?
We are focus on steel wire trading for more than ten years. We are specialized in export of various kinds of steel wire and wire mesh products, like Different Gauges Dark Annealed Wires with High Resistance. we offer high quality steel wire; hot dipped wire; electro galvanized wire; PVC /PE coated wire; fencing , steel wire rope, steel wire strand, cable wire; wire mesh and other wire related products.
② What is the advantage of our Different Gauges Dark Annealed Wires with High Resistance?
1. Durable service life and competitive price.
2. High quality and low price.
3. With good anti-corrosive
4. Beautiful, strong and not expensive.
③ How long can we receive the product after purchase?
In the purchase of Different Gauges Dark Annealed Wires with High Resistance within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.
- Q:If you put clay over wire and bake it would the wire melt and ruin the sculpture?Details on wire:I'm not sure what kind of wire it is but it says Bright Floral Wire..Wire is silverDetails on Clay:Again, im not sure what clay...its from polyform products and it says Premo Sculpey so im guessing Polymer? :#92;Clay is Black.Bakes for 275F (130C)30 minutes per/par/por1/4 in (6mm)
- No the wire won't melt - besides fuse wire or solder, the lowest common melting point wire is aluminum and it melts at over 1200F Floral wire is usually steel and melts at more like 3000F, but even if it were copper, that melts at about 1900F The real problem with using wire in polymer sculptures is that when the clay shrinks in baking it may pull apart along the wire or that you may make parts of your sculpture thin (like legs or arms) and part thick (like body or head) and thick clay tends to crack - so these parts need to be hollow, which is why people talk about crumpling heavy duty aluminum foil as a core, so the clay is more uniform in thickness all over. Don't forget to have an oven thermometer for accurate temperature checking - don't trust the knob setting on the oven.
- Q:Two wires are made of the same material but the second wire has twice the diameter and twice the length of the first wire. When the two wires are stretched, and the tension in the second wire is also twice the tension in the first wire. the funamental frequency of the first wire is 880 Hz. What is the fundamental frequency of the second wire?
- Since the tension and size are different the two wire will have different wave speeds Since v= sqrt(T/mu) mu can be represented by density * area Since the second wire has twice the diameter it will have 4 times the mu and since Tension in wire 2 is twice that in wire 1 v2 = sqrt(2T/4mu) sqrt(.5)*v1 = 0.707*v1 Since f1 (wire 1) = v/2L1 then f2(wire 2) = v2/2L2 so replacing v2 and L2 yields 0.707v1/(2*2*L1) = 0.707/2(v1/2L) = 0.707/2 *f1 = 0.707/2*880Hz = 311Hz
- Q:Im installing a motion sensor which comes with 3 wires,red black and white and want to connect it to a indoor light that only comes with 2 wires white and black.How do I go about installing them and powering them?
- To be honest, it seems you might be better served getting an electrician. If not... 1st, make sure to turn off the power. I'd imagine the red and black wires are for the incoming power (to the motion switch) and the outgoing power (from the motion sensor to the light). Look for markings on the wires or near where they go into the sensor (didn't this sensor come with instructions?), LINE designates incoming power, LOAD is for the load being served (the light). White is the common wire and will connect to the other white wire. If I had to guess, I'd say the red is incoming power, black is outgoing to the light. Whatever you do, BE CAREFUL, electricity is no joke.
- Q:Quick question with hopefully an easy answer. I had a dimmer switch go bad on a light in a dining room. I bought a new switch and put it in. It was working fine, so I thought, then I noticed that when the dining room light is off, the dimmer works on everything else on the circuit, for example outside lights, hall lights, etc. I can dim all of those things when this switch certainly didn't do that before. Also, if the dining room light is on, all of the other things on the circuit I mentioned before do not work at all. I've obviously incorrectly wired the switch somehow, any thoughts on what I did incorrectly and how to fix?
- The problem is going to be the THREE black wire connections. You have to identify the INPUT POWER wire to the box, the DINING ROOM wire and the 'EVERYTHING ELSE wire. Separate the three black wires. Measure between each black wire and the white wire bundle. The black wire that has 120 vac on it is your INPUT POWER wire. Momentarily connect the black INPUT POWER wire to each of the other two black wires. One of those other two black wires will light up the dining room light. It is that black wire that gets connected to the LOAD connection on the dimmer switch. The other black wire is your EVERYTHING ELSE wire. Connect that wire to the INPUT POWER wire. Run a pigtail from those two wires to the LINE connection of the dimmer switch.
- Q:I have a audiofonics adf-240 and I want to wire it to 1 ohm
- you do no longer cord the amp you cord the subs. seem up the wiring optons on your subs and notice the thank you to drop the ohms. remember you will make greater potential yet your amp will run warmer and wont final as long except carried out properly.
- Q:I am trying to run a wire from a breaker box to a new plug. To get to the new plug, I have to run the wire over a garage with a finished ceiling, around, through, or over 2 half staircases ( bi level) to get to the unfinished wall to run to the new plug. What would be the proper way to run this wire.
- That depends on your local and state codes and the conditions. Exposed? Concealed? All dry locations? Distance? I'd have to know way more to give you an accurate answer. Call an electrician to advise you.
- Q:I'm faced with a dilemma...I'm wiring my basement right now and all is fine, except for my living room. I want to have a 3-way switch setup, but with four light fixtures. I've already ran 3+ground wires in this order...Breaker box - Switch A - Fixture 1 - Fix. 2 - Fix. 3 - Fix. 4 - Switch B. I have done regular 3-way switches in the past, without much trouble, but I have no idea how to wire this, so well-explained instructions would be perfect.Thanks so much!
- A normal three way has two wires switch to switch and one wire from each switch to the single light. All you have to do is wire the lights in parallel, Each wire will go to one side of all three lights. The light to light wiring is no different then any other multiple light on one switch wiring. Except in this situation the two wires are coming from two different switches.
- Q:Hi,I'm trying to install a ceiling light with a 3 wire configuration (white, black, ground) into a wire configuration of 4 wires (white, red, black, ground). This is configured for two on/off switches.So far, I have white to white, black to black, and ground to ground with the red capped off. This works with one switch perfectly, however when I hit the other switch, the circuit breaker blows.Please help, and thank you!
- The three wire plus ground coming from the light to the switch, needs a FEED to the two switches! So, one of the three wires has to be connected to the feed. That would be the black wire. I believe that the white wire is one of the switch legs coming from one of the switches. That is why when you turn on the second switch, the breaker pops. Take that white wire coming up from the switch box off of the group of whites in the ceiling box and cap it.
- Q:I have a wire coming from the car battery positive terminal. It is 12v DC. I want to split this wire to two other wires. I cannot connect another wire to the positive terminal. Will splitting this wire cause the voltage to drop to 6v each wire? or will they pull a constant 12v each?
- Splitting would not reduce the voltage, but you have to check the load and make sure that wires are adequate to handle the currents involved.
- Q:I've been meaning to find floral wire for a DIY project I'm going to attempt. Does anyone know where to buy floral wire? I'm not sure if Michael's sells it. Please let me know from personal experiences.
- Where To Buy Floral Wire
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Different Gauges Dark Annealed Wires with High Resistance
- Loading Port:
- Tianjin
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m.t
- Supply Capability:
- 10000 m.t/month
OKorder Service Pledge
OKorder Financial Service
Similar products