Centrifugal Water Pump for High Capacity
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Centrifugal Water Pump for High Capacity
1.Structure of Centrifugal Water Pump Description
Centrifugal Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.
2.Main Features of the Centrifugal Water Pump Engine
•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel.
•Standard design is the pump group, the fuel tank, control panel, battery composite type.
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type.
•Can be designed according to customer requirement trailer (four or two wheels) moveable type.
3.Centrifugal Water Pump images
4.Centrifugal Water Pump Specification
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: Fire hydrant pump button, under what circumstances do not need to install?
- General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- Here is a 4 inch inch, not rural, 1 inches =25.4 mm, 4 inches is approximately 100mm, with DN100 pipeline.
- Q: How to install, operate and maintain the pipeline booster pump?
- The motor coil is provided with a safety protector, and when the pump is out of order or the water is not pumped, the motor can automatically break down when the temperature of the motor exceeds the prescribed value, and the motor can automatically resume operation after the temperature rise of the motor is decreased. The booster pump motor is a capacitor running type motor. When the pump leaves the factory, the rotation direction has been adjusted. If you need to replace the capacitor or re connect, press the arrow direction on the pump body to mark the connection. To ensure safety, use the three - core safety socket with ground wire.
- Q: What does electromechanical vector pump mean?
- Scope of application is;Residents living water: such as high-rise buildings, residential areas, villas and so onPublic places such as hospitals, schools, gymnasiums, golf courses, airports, etc
- Q: What are the basic technical parameters of the pump?
- The basic parameters of the pump, the basic parameters of the main performance parameters of pump are the following: first, water pump flow Q flow is the amount of liquid in the pump unit time delivery out (volume or quality). The volume of flow with Q that the unit is: m3/s, m3/h, l/s and so on. The quality of flow unit is expressed in Qm. T/h, kg/s and so on. The relationship between mass flow and volume flow is Qm= P Q density in P - liquid (kg/m3, t/m3), room temperature water P =1000kg/m3.
- Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
- The ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and rotor drive. The structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so the utility model can be completely free from leakage.
- Q: Operating procedures for measuring pumps
- Pressurization(1) for the discharge pressure below 2.0MPa, then the pump stroke length should gradually increase, each increase of 20%, to maintain 15 minutes.(2) for the discharge pressure greater than 2.0MPa, you need a special pressure, to ensure that the pump discharge pressure gradually increased, each time for the final row pressure of 20%.(3) when the pressure is not increased, the stroke of the pump is gradually increased by 20% strokes per time.Note (1) when pressure is applied, the pressure gauge should be observed at the side of the loading side (slow motion)(2) check ammeter, forbid overload
- Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
- Q: Harm of air pump and pump
- If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Send your message to us