• Centrifugal Water Pump for High Flow Rate System 1
  • Centrifugal Water Pump for High Flow Rate System 2
  • Centrifugal Water Pump for High Flow Rate System 3
Centrifugal Water Pump for High Flow Rate

Centrifugal Water Pump for High Flow Rate

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Specifications of  Centrifugal Water Pump for High Flow Rate

Horizontal single-stage split casing water pump

High efficiency

Easy maintenance

OEM/ODM

Good quality and service

2.Main features of  Centrifugal Water Pump for High Flow Rate

  • High quality centrifugal pump apply to industrial application.

  • Apply to power plant circulation.

  • Apply to water treatment.

  • Apply to agricultural irrigation.

  • Apply to flood control, hydraulic projects. 

3.Specification of Centrifugal Water Pump for High Flow Rate

 

Item

high flow rate centrifugal water pump 

 centrifugal water pump  

SH high flow rate centrifugal water pump

Model

SH

Material

Cast iron and customized

Color

Blue and adjustable

Mode

Horizontal

Impeller

Double suction impeller

Drive

Belt or coupling

Seal

Soft packing seal or mechanical seal

Speed

2950r/m, 1470r/min, 970r/min

Theory

Centrifugal pump

Structure

Single stage pup

Usage

Pure water or raw water

Power

Electric

Standard or Nonstandard

Standard

Application

Plant, mine, power station, urban water supply, irrigation

Outlet diameter

100-900mm

Capacity

111-12500m³/h

Head

8.6-140m

Power

22-1250kw

Warranty

1year

Certificate

ISO9001

OEM

Acceptable

Feature

High flow rate, high efficiency, easy maintenance

 

 4.FAQ

 What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

 Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

 What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we will

recommend relevant product for reference.

Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump
Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
Water ring vacuum pump is divided into many types, different sizes, different types, so water is different. As for how much water the no fixed amount, but to ensure that the water temperature is in 25 degrees, not more than 35 degrees can be.
Q: What should I pay attention to when buying a pump?
There are hundreds of water pump manufacturers in China, some of the family owned private enterprises are assembled in some areas, and the quality of the products is very good and bad, which makes it difficult to choose and buy. The main points are as follows:First, according to the required flow, lift, shaft power, efficiency, the necessary cavitation margin (or suction) and the use of conditions, the initial determination of the pump type, name, select the rated value and the required parameters of the same pump.
Q: What is cavitation, centrifugal pump cavitation phenomenon how to solve?
Centrifugal pump cavitation phenomenon how to solve?:Measures to improve cavitation resistance of centrifugal pumps(1) improve the design of the suction port of the centrifugal pump to the impeller. Increase flow area; the radius of curvature increases the impeller cover inlet section, reduce the flow accelerated sharply with pressure; reduce the thickness of the blade, and the blade inlet rounded, close to the streamline, can also reduce the acceleration and pressure flow around the blade head portion of the impeller and the blade inlet part; improve surface finish in order to reduce the resistance loss; the blade inlet edge extends to the impeller inlet, the liquid flow in advance to accept work pressure, improve.
Q: What is double hydraulic pump?
The 2 pumps are all coaxial connected together, driven by a motor, the general gear pump, piston pump
Q: What are the application areas of pumps?
Performance range from the pump to see giant pump flow up to hundreds of thousands of cubic meters per hour, while the micro pump flow per hour in a few milliliters; pump from atmospheric pressure up to 19.61Mpa (200kgf/cm2); the lowest temperature of the liquid is transported up to -200 DEG C, up to 800 DEG C. Pumps carry a wide variety of fluids, such as water (clean water, sewage, etc.), oils, acid and alkaline solutions, suspensions, and liquid metals.In the chemical and oil sector production, raw materials, semi-finished products and finished products are mostly liquid, and semi-finished and finished products to raw materials, need to go through a complex process, to pump and provide transportation of liquid chemical reaction of the pressure and flow in the process, in addition, the device also used in many pumps to adjust the temperature.In agricultural production, the pump is the main irrigation and drainage machinery. Rural areas in our country are vast and vast, and a large number of pumps are needed every year in rural areas. Generally speaking, agricultural pumps account for more than half of the total output of pumps.Pumps are also the most widely used equipment in the mining and metallurgical industries. The mine needs pumping and drainage. In the process of ore dressing, smelting and rolling, the pump needs water to supply water first.
Q: Does the reservoir water heater press the booster pump (high marks)?
If insufficient pressure really, adding an automatic booster pump in the water inlet, is feasible. Home booster pump, a basic model, to sell the place to ask the next to know, generally 200 yuan or so, traffic 0.3-1.8, 90~150 watts on it. Do not buy too large, too much power, the water will also be too large, but the water heater will not be used.
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q: Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
Submersible pump is best in the water, if dry pumping will cause burns.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords