Description Of 0.4KW~400Kw Inverter Frequency
CMAX frequency inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of 0.4KW~400Kw Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of 0.4KW~400Kw Inverter Frequency
Application Of 0.4KW~400Kw Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of 0.4KW~400Kw Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
- can use. But in the inverter "motor parameters" to be some changes. Such as the number of poles, rated current.
- Q: Can the laptop's power adapter be used for years?
- Most laptop power adapters can be used for 100 ~ 240V AC (50 / 60Hz). Basically, most of the notebook computers are external power supply, with a power cord and the host connection, which can reduce the size and weight of the host, only a very small number of models built in the host power.
- Q: I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
- wo recommendations, the first, the use of vector control of the inverter, you are expected to run the frequency of about 5Hz, this time, ordinary V / F inverter output torque may be small, not necessarily meet the requirements, of course, if it is High-end imported inverter, the problem should be small, with the domestic vector inverter, the frequency can also be full torque output;
- Q: Will the 75KW4 pole motor can be used to increase the speed of the inverter?
- China's power frequency 50hz, and the motor rated frequency match, blindly by increasing the frequency of the inverter output motor speed is not desirable, will affect the motor magnetic circuit, work is not normal.
- Q: How does the variable frequency motor output torque at very low frequencies?
- Low frequency, the motor torque is relatively low, generally VF inverter performance is good or bad, the price level reflected in this time. But there is torque to enhance the function, it will not move without moving. If no load can not start, check the motor card and other mechanical problems such as whether there is a problem.
- Q: Inverter problem
- (0 ~ 20mA), but the main input / output is completely isolated, than the output of the inverter simulation of the output of the analog output The amount of signal impact resistance, anti-interference ability.
- Q: What is the maximum speed adjustable for a 4-stage motor with a rated frequency of 50Hz / 60Hz?
- Generally transferred to 60Hz, about 1800 rpm, although the maximum speed when the inverter speed adjustable to 135Hz, but the motor does not work. Bearing first to consider.
- Q: Inverter 0.2KW, the motor speed requirements down to 4 turn, the motor pole 4 pole. Can the drive drive the motor?
- The first calculation: 4-pole motor, rated 1450r / min divided by 50HZ, then it is 29r / HZ. Your request is 4r / min, then the frequency of the inverter must be 0.1 less than 0.2HZ without load are compared Difficult to achieve. You can do the test, then you can try to play, if used to produce what is the best or reducer, so the inverter and the motor are good.
- Q: How to learn the inverter debugging and design parameters
- Personally think it is relatively simple, and now the inverter has been more intelligent, and some simple applications, and even do not need to set the parameters.
- Q: What is the IGBT? Our inverter IGBT fried,
- Name is the FET, the price of this thing is more expensive,
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
0.4KW~400Kw Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords