Description Of 0.4KW~400Kw Inverter Frequency
CMAX frequency inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of 0.4KW~400Kw Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of 0.4KW~400Kw Inverter Frequency
Application Of 0.4KW~400Kw Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of 0.4KW~400Kw Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: Laptop warranty period is not over, the power adapter is broken, repair money?
- Have to admit that the emergence of Thinkpad x100e, will hit the Internet completely decent, this product is not the name of the Internet, but "ultra-portable notebook", which also shows the x100e relentless and the Internet is willing to belong to similar products. It can be said, x100e is turned out in 2010 turned out professional jet client!
- Q: Inverter alarm a043, how is it
- When there is a signal failure, if necessary, use DTI Board, if necessary, change P215 In addition, for the synchronous motor (P095 = 12): the inverter is released until the motor is at rest
- Q: 5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
- Because the frequency converter can reach 60 Hz frequency, while the three-phase power supply is the standard 50 Hz. So the inverter can make the motor speed faster than the rated 1500 rpm. The fastest up to about 1800 turn.
- Q: Will the motor suddenly stop when the inverter is suddenly powered down?
- but there are exceptions, such as head pump, water hammer effect after power failure will make the motor Reversal
- Q: Abb inverter s510 with water circulation pump why the motor fever. The motor is 2 pole
- Check the inverter operating power factor, straight up the motor to see if it is overheating
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- This should be the meaning of the drive block, that is, the drive signal is locked, there is no drive signal, and start a frequency change but no voltage output, you find someone to repair the circuit board can be used normally, this is generally the circuit board Problem, the module is less likely to be bad
- Q: Whether the inverter can control the start and stop of the horizontal monopole centrifugal pump
- Can be installed by a simple float level control to achieve, the general frequency is to constant pressure, of course, start and stop is completely controlable Oh. It's good for the pump to start the speed change
- Q: How do I select a drive? Which brand is better
- ???4, when the inverter is used to control several motors in parallel, be sure to consider the inverter to the motor cable length of the sum of the inverter in the allowable range. If you exceed the specified value, to enlarge one or two steps to select the inverter. In addition, in this case, the inverter control mode can only be V / F control mode, and the inverter can not protect the motor over-current, overload protection, this time in each motor on the fuse to achieve protection. ????5, for some special applications, such as high ambient temperature, high switching frequency, high altitude, etc., this time will cause the inverter derating, the inverter need to enlarge a file selection. ????6, the use of inverter control high-speed motor, due to high-speed motor reactance small, high harmonics also increase the output current value. Therefore, when selecting a frequency converter for a high-speed motor, it should be slightly larger than the inverter of an ordinary motor. ????7, the inverter for the variable pole motor, should pay full attention to select the inverter capacity, so that the maximum rated current in the inverter rated output current below. In addition, in the operation of the number of pole conversion, you should first stop the motor work, otherwise it will cause the motor idling, bad will cause damage to the inverter.
- Q: The laptop's power adapter is too hot to do
- Installed adapter heat should be no problem, I am now under the books, the fan mouth is very hot, the weather may be more and more hot it
- Q: Three motors, if coupled with the governor speed, is it necessary to add the inverter?
- ?Second, the variable speed: change the way the stator winding wiring to change the cage motor stator pole pairs to speed.
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
0.4KW~400Kw Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords