Description Of 0.4KW~400Kw Inverter Frequency
CMAX frequency inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of 0.4KW~400Kw Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of 0.4KW~400Kw Inverter Frequency
Application Of 0.4KW~400Kw Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of 0.4KW~400Kw Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q:Can the laptop power adapter be generic?
- Not common. Different computer adapter interface is not the same, and the voltage, current is not the same. If just the same, you can use, the voltage can also be used.
- Q:ASUS power adapter Acer can use it
- 2. Is the adapter's output current consistent with the notebook's requirements? (Or a little bit of the current is also not.)
- Q:Is the laptop power adapter AC and DC?
- Most laptop power adapters can be used for 100 ~ 240V AC (50 / 60Hz). Basically, most of the notebook computers are external power supply, with a power cord and the host connection, which can reduce the size and weight of the host, only a very small number of models built in the host power.
- Q:90KW inverter start 90KW, 4-pole motor and 6-pole motor j What is the difference? The inverter can be used for it?
- The number of poles of the motor and the inverter is not very different, the difference is the motor speed is different
- Q:What is the laptop adapter
- 4, the working principle: the use of unstable power supply switching power supply principle through the conversion circuit into the notebook computer needs constant voltage DC, to the laptop computer power supply and charging; it is worth noting that: this conversion circuit, there must be protection circuit (Overcurrent protection circuit, overvoltage protection circuit short circuit protection circuit, etc.), to prevent accidents, the protection of the laptop will not burn.
- Q:What is the motor series parameter setting of the inverter? If it is with the spindle,
- The number of motor poles can be estimated by the parameters: 1000Hz corresponds to 60000rpm, According to "Speed in rpm = 60 * Frequency in Hz / (Number of Poles / 2)", Number of poles = 60 * Frequency indicated by Hz * 2 / Speed in rpm = 60 * 1000 * 2/60000 = 2 poles. The same is true with 333Hz and 20000rpm projections. The number of motor poles for the frequency converter should be entered with the number of poles of the motor that are directly connected to the frequency converter.
- Q:Inverter problem
- (0 ~ 20mA), but the main input / output is completely isolated, than the output of the inverter simulation of the output of the analog output The amount of signal impact resistance, anti-interference ability.
- Q:Lenovo g450 laptop power adapter specifications is what?
- Lenovo G450 power adapter Model: ADP-90RH B LENOVO P / N: 36001681 Input: 100-240V ~ 1.5A 50-60Hz Output: 19V $ 4.74
- Q:Is the number of Amps of the notebook power adapter higher than the original number of security on the computer?
- The current amperage of the power adapter is only experienced at its maximum output power, as long as the power adapter output voltage and your original no problem. For example, when the home circuit from the power supply into the terminal does not limit the size of the current, but to provide a fixed voltage. The more your household appliances, the greater the current through the power supply into your home. And the indoor air break switch is a current limit, this is based on the ability to accept the wire. From the point of view of the meter, you use the power equal to UIt = W, where UI is the voltage and current, two multiplication is equal to power, power multiplied by time equal to power consumption. Say back to your power adapter, the power adapter output voltage is rated, as long as this notebook with your original output voltage is the same as your notebook will not hurt. And the power adapter current is the maximum output, the consciousness is the power adapter output maximum power P will not exceed this value, usually 65W or 90W. Greater than the power of such a computer can not be stable operation. Or a physical point of view, the use of notebook power adapter, in fact, the internal is a number of parallel circuits, secondary knowledge tells us the voltage of the parallel circuit at any end are the same size, and parallel devices, the greater the total current in the circuit The
- Q:Who knows how the frequency converter works
- 2. flat wave circuit In addition, the ripple current generated by the inverter also changes the DC voltage. In order to suppress the voltage fluctuation, the inductor and the capacitor absorb the pulsating voltage (current). In general, the DC voltage of the rectifier is rectified and the DC voltage is rectified. General inverter power supply of the DC part of the main circuit in terms of margin, so eliminating the need for a simple capacitor filter smoothing circuit.
1. Manufacturer Overview |
|
---|---|
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b)Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
0.4KW~400Kw Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords