90KW AC Motor Use Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features of 90KW AC Motor Use Converter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure of 90KW AC Motor Use Converter Frequency
Application of 90KW AC Motor Use Converter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance of 90KW AC Motor Use Converter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q:400w 6-pole motor should be equipped with much of the inverter?
- Under normal circumstances, the market are sold on the inverter are based on the common 4-pole motor matching, when to match the 6-pole motor, the inverter to a large power level, which is 400W of the first-class power 0.75KW, and so on
- Q:What is the difference between the collector and the emitter mode?
- While the base area should be very narrow So bjt is not a symmetrical device
- Q:Siemens g120 inverter torque limit what is the meaning
- For example, you have 100kg of power, but you can send the power and you lift the weight of the object, if the object weight of 10kg, you can only use 10kg of power.
- Q:How do I select a drive? Which brand is better
- ??8, drive explosion-proof motor, the inverter is not explosion-proof structure, the inverter should be set in a dangerous place outside. ????9, the use of inverter drive gear motor, the use of the gear by the part of the lubrication part of the lubrication control. When lubricating oil is lubricated, there is no limit in the low speed range. If there is a high speed range above the rated speed, there is a risk that the lubricating oil may be used. Therefore, do not exceed the maximum speed allowable value. ????10, the inverter drive winding rotor asynchronous motor, most of the use of existing motor. Winding motor and ordinary squirrel-cage motor compared to the winding motor winding impedance is small. Therefore, it is prone to overcurrent trip due to ripple current, so a frequency converter larger than the normal capacity should be selected. General winding motor for flywheel torque more occasions, in the set acceleration and deceleration time should pay more attention.
- Q:Yasukawa inverter reported bb code that is the reason why the base blockade?
- This should be the meaning of the drive block, that is, the drive signal is locked, there is no drive signal, and start a frequency change but no voltage output, you find someone to repair the circuit board can be used normally, this is generally the circuit board Problem, the module is less likely to be bad
- Q:What is the maximum speed adjustable for a 4-stage motor with a rated frequency of 50Hz / 60Hz?
- Motor speed and frequency of the formula N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (seconds); F - power frequency (Hirsch); P - pole pairs of motor rotating magnetic fields. China provides the standard power frequency f = 50 weeks / second, so the rotation of the magnetic field of the size of the theoretical diameter only with the magnetic pole. The number of pole pairs is large, and the rotational speed of the rotating magnetic field is low.
- Q:Three-phase asynchronous AC motor speed control method
- Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor loop into the adjustable additional potential to change the motor slip, to speed control purposes. Most of the slip power is absorbed by the additional potential in series, and the additional device is used to return the absorbed slip power to the grid or to convert the energy. According to the slip power absorption and utilization, cascade speed can be divided into motor cascade speed, mechanical cascade speed control and thyristor cascade speed form, the use of thyristor cascade speed, which features: Can be transferred in the speed of the process of slip loss back to the grid or production machinery, the higher efficiency; Device capacity and speed range is proportional to the investment province, for the speed range of 70% -90% of the rated speed of production machinery; Speed ??control device failure can switch to full speed operation, to avoid shutdown; Thyristor cascade speed power factor is low, the greater the impact of harmonics. This method is suitable for use in wind turbines, water pumps and rolling mills, mine hoists, extruders.
- Q:Is the number of Amps of the notebook power adapter higher than the original number of security on the computer?
- Sure answer, no! Rest assured with it, but be careful not to buy the cottage goods, this on the computer and security is not good. good luck!
- Q:Who knows how the frequency converter works
- Rectifier circuit The function of the rectifier circuit is to convert the AC power into a DC power supply. Rectifier circuit is generally a separate rectifier module.
- Q:Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
- 7 seconds more than a change, too often. It is estimated that the inverter will not work. Suggest:
1. Manufacturer Overview |
|
---|---|
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
90KW AC Motor Use Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords