Automatic Door With Linear Magnetic Drive

Automatic Door With Linear Magnetic Drive

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:
China (Mainland)
Brand Name:
CMAX
Model Number:
Exterior Slidng Door
Open Style:
Sliding
Position:
Interior
Surface Finishing:
Finished
Type:
Sliding Doors
Sliding Door Type:
Partition Doors
Door Material:
Glass
Size:
as customer required
Hardware:
Germany Roto, Siegenia-Aubi, Chinese Top Trademark-KinLong, etc.
Surface treatment:
Mill finish,powder coating, electrophoresis, wooden transfer etc
Standard:
AS2047, CE, SONCAP, etc..
Glass:
tempered glass/insulated glass/low-e glass/reflective glass etc.
Opening pattern:
vertical/horizontal/swing
Profile color:
white, green, grey ,blue, Bronze, wood grain
Style:
American & European style, China style
Aluminum thickness:
2.0mm
Name:
Exterior Slidng Door


Packaging & Delivery

Packaging Detail:Bubble bag + Inner carton + Outer carton
Delivery Detail:3 days

1. Brief Introduction of Exterior Slidng Door

1). The material for the window is Aluminium profile

2). The thickness for Aluminium profile is 2.0mm,

3). The design& size& color could be make by customers's requirement

4). Glass kinds  we have : insulating  glass. tempered glass, low-e glass ,laminated glass

5). glass thickness : 5mm+9A+5mm . 5MM+ 12A+5MM.6mm+9A+6mm  6MM+12A+6MM

2. Design Features

1)  Production is completely in accordance with the ISO9001 quality management system and environmental system and security system

2)  Provides insulation from draughts, rain & noise with a self-draining aluminum tread

3)  Superior energy efficiency provided by sealing around the door jamb & tread

4)  Various glass types available for doors and windows

5)  Sill seal fitted as standard for the doors and windows

3. Techinical Data of Exterior Slidng Door

Type Option

Exterior doors/interior door/balcony door/emergency door/weather door

Frame color

Silver, bronze, black, gold, blue, grey, champagne, bright

Size

1000×2100mm,1200×2100mm,1500×2100mm or as you request

Frame Material

Aluminum profile with 2.0mm thickness

Aluminum Option

Normal aluminum profile, Thermal-Break aluminum profile

Glass Option

Clear glass, Laminated glass, Tinted glass, Low-E glass, Frosted glass, tempered glass

Single glass: 4mm, 5mm, 6mm, 8mm, 10mm, 12mm and etc

Double glass: 5+9A+5mm, 5+12A+5mm, 6+12A+6mm and etc

Triple glass: 6+9A+6+9A+6mm and etc

Hardware

China famous brand / German brand

sealant

EPDM, Silicone Sealant

Fly  Screen

Metal and Nylon material for option

Opening Method

Inwards or Outwards, right or left hand opening as your requested

Surface Treatment

Mill finish, anodizing, powder coating, electrophoresis, wooden transfer or fluorocarbon coating, polishing, sand blasting

Lifetime

Above 50years

Scope of Application

Apply to commercial houses, hotels, villas, office buildings, prefabricated houses and etc.

Temper

T5 or T6

Quality standard

China National Standard GB/T 5237 -2008 (advanced class)

Certification

ISO9001,CE



Functional features:

(1)Exists in double and single sliding versions;


(2)Powerful and full functions: offer our users 4 operating options of full automatic,half open, constant open and constant lock;


(3)Flexibility:allows tempered glass door leaves as well as 50mm thickness wooden door leaves;


(4)Reliability:built-in microprocessor ensures the accuracy and precision of the operation;


(5)Safety:the door leaf(ves) will go backward when people or moving obstacles approach while closing,which prevents the clamp injury and damage of the door itself.


(6)The door leaf(ves) could be deftly manually opened at a power failure;


(7)Modularization design allows a simple and easy installation;


(8)Purpose made polyurethane covered silent wheels realize quiet operations;


(9)Multiple optional access method:

a.Sensors: microwave sensor,feet sensor;

b.Password:password or finger print identification access;

c.Card:IC card,RFIC card;

d.Button:Elbow touch,feet touch and long-distance buttons.


sage Specialty:

Microcomputer technology, self-learning.
Opening delay time can be adjustable.
Permanent open/full open/half open/exit/lock/manual mode
Safety lock(optional)
Self-check and display error code by LED
Motor run smoothly & safely.
Big size wheel(high quality POM material)
Easy install on top or on side direction.
Motor/Controller/Belt free to maintenance
Special three wheel hang device void chance of digression
Can link to another auto door system, realize one door open (while another one close) to reduce heat change
Power off can open door/close door (for fire protection etc. )





Q: The automatic door controller does not have a display speed
There are several holes in the controller panel, there are cross in the hole, adjustable
Q: I got my automatic garage door open and drove my car in and when I tried to close it I get no power. A light comes on but it doesn't operate. Do I need a new motor or what is wrong?
Lots of things could be wrong #1 check the battery in the remote in your car #2 check the settings switch on the opener, it has a sensitivity setting #3 Check the sensors for two things First see if they are blocked. Secondly, as the year progresses, the angle of the sun changes and when direct sunlight at a certain time of the day hits the sensor, it will not open or close as it gets canceled out from the light. I had a customer one time that had this happen and it took us 2 hours to figure out that was what it was. I ended up moving the sensor up higher so the ledge of the roof would block the sun from the sensor, although that is actually a code violation as it has to be low enough so a child cannot be crushed by the door
Q: Is it possible to express an automatic door?
In the days of the library which can be found inside
Q: Double flash automatic doors, only one door has a sense of another reason why the door is not sensed
Two-door interlocking means that a door in the open state of another door you go to induction it will not open, you must wait for the door closed, another door to be able to sense it to open. According to the need to connect the interlock, if not directly remove the interlocking wiring.
Q: Iveco automatic door switch how to install?
Open the door signal is also called contact signal, microwave radar and infrared sensor is commonly used in two kinds of signal source; 2, key switch; 3, foot switch; 4, timer. The main contents are as follows: 1, automatic door opening signal is the contact signal, microwave radar and infrared sensor is commonly used in two sources: microwave radar is the object of the displacement response, and thus the reaction speed, suitable for people walking normal Through the place, it is characterized that once the door near the staff do not want to go out and still do not move, the radar will no longer react, automatic doors will be closed, the door machine has a certain protective effect. Infrared sensors react to the presence of objects, regardless of whether the person moves or not, as long as it is within the scanning range of the sensor, it will react to the outgoing contact signal. The disadvantage is that the infrared sensor response speed is slow, suitable for people with slow access to the place. 2, the key switch can be a touch-type button, more convenient is the so-called elbow switch. The elbow switch is very durable, especially if it can be operated with an elbow. Avoid contact with the hand. 3, foot switch, function the same, but the higher requirements of the waterproof, and the foot of the great force, easy to foot switch failure. There is also a handle with a contact switch, when the handle is pushed (or in the opposite direction of the pull) in place, the door to provide contact signal. 4, the timer can automatically control the state of the door, the principle is to connect the clock with a specific switch circuit can be preset time will automatically open the door or lock the door state.
Q: My garage door dosent lock right now and I dont have a key to it,If i get a automatic garage door opener will it lock by itself when it closes.
If you are installing new automatic opener it will hold it self down till you press the button on the opener. If you have a Handel on the garage door that you twist to open the door do you self a favor and remove the latching plates on the garage door rails. If you don't remove them when it closes it will latch in place and when you open it it could damage the garage door or it will not open at all.
Q: Electric door tax returns which industry details
According to the national economic industry classification (GB / T 4754-2017) Electric door Should be attributed to the C category manufacturing, 33 categories of "metal products industry", 331 in the "structural metal products manufacturing", 3312 Subclass "Manufacture of metal doors and windows" refers to the production of doors and windows and the like for building buildings with metal materials (aluminum alloy or other metal)
Q: What is the design principle of the automatic credit card?
Yes! Upstairs to answer the easy to understand! I will not say more! How do you want to install automatic doors! Swipe open the door can also add a lot of features! Such as a fixed time can swipe open the door! After a time on the card can not open ah! Can be set up!
Q: There is no relevant laws and regulations stipulated 'when the fire, the automatic doors need to automatically open' some brothers speed help out
"When the fire, the automatic door to automatically open", have not seen such a requirement, you are not want to understand some of the installation of the access door to escape the fire in the relevant provisions of the fire. "Building design fire safety regulations" GB50016-2006 in the 7.4.12 of the provisions of Article 4: personnel-intensive places usually need to control the discretion of the evacuation door, or with access control system of residential buildings outside the door, should ensure that the fire No need to use any tools such as keys can be easily opened from the inside, and should be set in a prominent position logo and use tips. ???? If the fire door, then it is required in the fire is in a closed state, requiring the doors of the door closer function, that is, people through the door, the door can be automatically closed in time, the only way to achieve fire partition and smoke effect. Is in the architectural design fire safety specification is required to close instead of open!
Q: Now everyday doors go back to the ancient times of Egypt. Which were seen in the picture that showed single and double doors so it's hard to tell who really invented it. So my big question NOW is who invented the automatic sliding door?
The real question is who invented glass. Thats where sliding doors came from.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords