Anodized Aluminum Extrusion Profile
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Kilograms pc
- Supply Capability:
- 3000 Tons per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features:
1.Material: AL alloy 6000 series, 3000series, 5000series .
2.Temper: T0-T5, H112
3.The size are available in accordance with customers' requirement.
4.Beautiful appearence ,good resist compresion and anticorrosion.
5.Various surface finish: Mill finish, Powder Coating, PVDF coating, PVF2 coating, Anodizing, Sandblasting, Cataphoresiscoloring etc.
6.Package: According to customer'srequirements. Such as: Foam Paper and Carton Box package,Kraft Paper package,Plastic Film and the Plastic Wrap package etc.
7.Use: industry, decoration, furniture, part of luggage etc
8.Color: Silver,Golden,Black,Red,Blue and so on
We can mould and manufacture the aluminum profiles as per customers’ requirements.
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Because some transformers are connected to 380V and 0, they can be 1000VA capacity, but because of the same line diameter, the 220V terminals and 0 can not provide the capacity of 1000VA.
- Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
- Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
- Q: Why should lighting transformers be used in factories and mines?
- But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
- Q: Why is elevator lighting transformer installed?
- Is that the kind of 220V change 36V ah, if it is that kind of thing, I think it should be for security reasons. After all, 36V is a safe voltage. The damage to humans is slightly smaller than that of 220V.
- Q: The transformer zero line has broken, has the result to the household illumination circuit?
- The zero line is connected to the transformer neutral point of transformer, three FireWire for its voltage is 220 volts, according to regulations, the total can not take the zero line fuse, switch, because once the zero line is disconnected, the rest of the line will no longer be a neutral line, into the use of electrical appliances connected to two the conductor, according to the characteristics of series circuit, each phase with electrical voltage, on load distribution, change the original load smaller which phase by using electrical appliances, will damage due to excessive voltage.
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
- Q: Can the 500 volt lighting transformer be changed into an electric welder?
- The structure of the electric welding machine is different from that of the transformer, and the magnetic gap of the iron core can be adjusted so that the welding current can be changed. In addition, the output voltage of the welder is also soft
- Q: Power and lighting transformers, lighting quality will be affected much?
- First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
1. Manufacturer Overview
Location | Jiangsu,China |
Year Established | 2010 |
Annual Output Value | |
Main Markets | Middle East, South Asia, America, Europe |
Company Certifications | ISO14001:2004 ;ISO9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | 54,000 square meters |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Anodized Aluminum Extrusion Profile
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Kilograms pc
- Supply Capability:
- 3000 Tons per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords