ZWII series self-priming sewage pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product overview
ZW Ⅱ series self-priming and non-clogged sewage pump is our study of domestic and foreign similar technology is developed on the basis of a new structure of the product. ZW Ⅱ series self-priming without clogging self-priming sewage pump set and blocked sewage into an organic whole, the axial back mixing type, can be like general self-priming centrifugal pump, do not need to install the bottom valve and irrigation water diversion, and inhale row containing large granular solid and liquid long fiber impurities.
Application field
Municipal drainage project, studied the breeding,
Light industry, papermaking, textile, food
Chemical industry, electric power, fiber
Paste and mixed suspension medium
- Q: What are the meanings of the vacuum pump, the front pump and the main pump?
- The main pump and the front pump with the general vacuum unitThe front pump can be understood as a mechanical pump. It can be used by itself, but the pumping rate or the vacuum can not meet the requirements. In this case, we add a booster pump
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
- Q: Water pump outlet valve sequence
- In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
- Q: Double floor sewage pump circuit diagram of a small problem
- Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What is pump suction work?
- Pump is mainly used to transport liquid, including water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, etc., also can transport liquid, gas mixture and liquid containing suspended solids.
- Q: How many pumps does the 80cm tank use?
- For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
- Q: Harm of air pump and pump
- Centrifugal pump situationEmpty pump is divided into two kinds, if there is no liquid, then it will cause the mechanical seal of the pump to overheat, wear and even die
- Q: What are the differences between the sewage pump and the clean water pump?
- Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
- Q: What is the distance between the pump and the wall?
- What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Send your message to us
ZWII series self-priming sewage pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords