Self-Priming Sewage Pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 35000台 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.Peripheral pump2.Brass impeller
3.Copper wire
4.Single phase
5.1 year warranty
1'' 0.75hp self-priming sewage pump
♦PUMP
1.cast iron pump body
2.brass impeller
3.AISI 304 shaft
4.MAX. liquid temperature:+60°C
5.MAX.suction:+9m
♦MORTOR
1.C&U bearing
2.Motor with copper winding,
3.Bult-in thermal protector for single phase motor
4.Insulation class:B.
5.Protection class:IP44
6.MAX.ambient temperature:+55°C.
♦FEATURES
1. CE, GS certificate
2. 100% copper wire, automatic wiring.
3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and
precision.
4. CNC precision automatic lathe for smoother shaft.
5. Strict tests include water test, outgas test and performance test, ect.
6. Anti-rust treatment castings and electrophoresis.
7. 23-year experience, 1 year warranty.
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- (1) pump connected outside pipes, containers, pipes, joints and other leakage test instrument, large leakage, rotary gas plug exhaust sound big, and the gas and oil mist discharge, should find leakage cancellation.(2) the assembly of rubber of intake pipe is not proper, damage or aging should be adjusted or replaced.(3) plug hole, the vacuum degree can be decreased, put the oil, remove the tank, loosen the nozzle plate, pull out the oil inlet nozzle, dredge oil hole, try not to use cotton wipe parts.(4) the vacuum system has serious pollution, including containers, pipes and so on. It should be cleaned.(5) the spring of the vane is broken and should be adjusted.
- Q: What is the minimum continuous flow of a pump?
- Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
- Q: What are the ways of hydraulic pumps?
- There are several ways:Direct flow mode, such as external gear pump;Port plate, such as vane pump, axial piston pump, etc.;
- Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
- Difference:The installation position is different: one can discharge water, one is on the ground.The work principle is different: the principle of submersible pump is similar to the electric fan, centrifugal pump through centrifugal force to make the water throw out. According to the principle of centrifugal force design,
- Q: Operating procedures for measuring pumps
- First, preparation and inspection before starting1. Check to make sure that the drain line is equipped with a safety valve with the correct set pressure.2. Check the screws for the liquid end parts.
- Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
- The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
- Q: How high can the pneumatic diaphragm pump be?
- Diaphragm capacity, high temperature, pneumatic diaphragm pump ability, high temperatureMany users do not know how high the temperature resistant diaphragm pump, diaphragm pump either electric diaphragm pump or pneumatic diaphragm pump products it cannot do without diaphragm attachments, diaphragm materials mainly fluorine rubber, rubber, rubber, polyether road three EPDM, PTFE several, if not considering the gas temperature resistant diaphragm made of stainless steel. The temperature to 600 degrees of diaphragm pump diaphragm pump, but must use the diaphragm, so the diaphragm pump can Naiduo high temperature depends entirely on the diaphragm was affected by temperature, following to share various diaphragm pump diaphragm material and different material temperature choice diaphragm pump product right:
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- Maximum theoretical vertical transfer distance is m 270Maximum theoretical level conveying distance m 1200Distributing valve form S pipe valve (whole casting)
- Q: What is an industrial water pump?
- The pump has the different uses, conveying different liquid medium, different flow rate, different lift range, therefore, its structure of course is not the same, the material is different, in general, can be divided into:1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
- Q: How to maintain and repair the booster pump of pipeline pump?
- I. installationAssembly and disassembly1. scrub all the spare parts to be cleaned.2. mechanical seals are installed on the main shaft of the motor, and a small amount of clean turbine oil or 20 oil is added to the surface of the mechanical seal.
Send your message to us
Self-Priming Sewage Pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 35000台 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords