ZX Self-priming Pump, Self-priming Sewage Pumps, High Quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
development of pump energy saving products.Self-priming centrifugal pump, the pump and other pump does not have the self-priming capacity, etc.Such as corrosion resistant mechanical seals and stainless steel material can call some of the chemical, pharmaceutical acid and alkali medium.
Second, the product features
1, the pump with self-priming function, do not need to install the bottom valve in pipeline, only to ensure storage in pump body before work are quantitative liquid can have "a drainage, life-long self-priming" function.So both simplifies the pipeline system, and improved the working conditions.
2, has a compact structure, convenient operation, stable operation, easy maintenance, high efficiency, long service life.
Three, use the product
1) suitable for urban environmental protection, construction, fire control, chemical, pharmaceutical, dyes, and dyeing, brewing, electric power, electroplating, papermaking, oil, mining, equipment cooling, tanker unloading, etc.
(2) apply Yu Qingshui, sea water, chemical liquid medium with acid, alkalinity and with general mushy slurry (medium viscosity 100 mile, or less under the solid content of 30%).
(3) mount a rocker arm sprayer, the water can go into the air, a small drips to spray, is a good tool for farm, nursery, garden, tea garden.
And (4) can be matched with pressure filter of any model and specifications, sending size belt filter to filter the most ideal auxiliary pump.
Fourth, working conditions
Traffic: 3 ~ 500 m3 / h
Head: 10 ~ 80 m
Ambient temperature 50 ℃ or less
Medium temperature is 100 ℃ or less
Medium density of 1.24 or less by 103 kg/m3
- Q: What are the meanings of the vacuum pump, the front pump and the main pump?
- In operation, the main gas extraction limit vacuum is achieved by the main pump, so we call it the main pump, which plays the main role of the pumpThe front pump is the pump that needs to be opened ahead of the main pump. It is called the pump before the main pump and the pump running the main pumpIf you don't understand, look at your signature and ask again
- Q: What is the minimum continuous flow of a pump?
- The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
- Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
- Water ring vacuum pump is divided into many types, different sizes, different types, so water is different. As for how much water the no fixed amount, but to ensure that the water temperature is in 25 degrees, not more than 35 degrees can be.
- Q: What is the pump, how to classify, mainly used in where?
- 1. vane pumpThe impeller pump is driven by the impeller to rotate the liquid at high speed and transfer mechanical energy to the transported liquidAccording to the pump impeller and runner structure characteristics can be divided into different:1) centrifugal pump2) axial flow pump3) mixed flow pump4) vortex pumps3. jet pumpA high velocity jet produced by a working fluid is used to eject the fluid, and then the energy of the ejected fluid is increased by momentum exchange
- Q: What's the difference between non negative pressure and variable frequency water pump?
- When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
- Q: What is a positive displacement pump? He Weizheng displacement?
- The principle and structure of displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow
- Q: Water pump does not produce water, what are the reasons?
- 1 check whether the motor is reversed.2, to see whether the export, the entrance blocked, the outlet pressure gauge whether there is pressure.3, whether the pump selection is wrong, you can not suck up the water.
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
- Q: How can I buy a pump?
- 3 、 mechanical requirements of high reliability, low noise, vibration.4, the correct calculation of pump procurement costs, the pump manufacturer to inspect, requiring good quality equipment, good after-sales service, spare parts can be timely supply.The micro pump and the motive of the mechanical energy or other external energy transmitted to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids.The technical parameters of pump performance include flow, suction, lift, shaft power, water power, efficiency and so on.
- Q: How to maintain and repair the booster pump of pipeline pump?
- Two 、 troubleshootingfaultReasonRemoval method1. water pump does not produce waterThe water injected into the water pump is not enough, the rotation direction is not right, and the impeller passage is blocked.Pump water into the pump, pass through the impeller runner, adjust the direction of rotation.2. pump flow is insufficientThe pump speed is too low, part of the blockage, the total lift pump is higher than the rated value, the damage to the impeller.Clean the water pump and pipe, replace the impeller, increase the pump shaft revolutions, adjust the outlet valve.3. lack of outlet pressureThere is air in the liquid, the speed is too low, the impeller is damaged and the outlet valve is open.Exclude liquid air, increase the pump speed, replace the impeller, adjust the small outlet valve.
Send your message to us
ZX Self-priming Pump, Self-priming Sewage Pumps, High Quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 400 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords