• YHZKB-2X series System 1
YHZKB-2X series

YHZKB-2X series

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
2X-Series
The type two-stage oil-sealed mechanical pump system varactor vacuum pump, which has the characteristics of the exhaust directly to the atmosphere is suitable for electronics, refrigeration, electric light, chemical, medical, bottle lamps, packaging, dehydrating, drying and other industries. (But can not be used for extraction of oxygen is too high, there are explosive, corrosive to metal on the vacuum oil from the chemical reactions, as well as containing the particles, dust, gas, also can not serve as pumps and compressors use.Motor power:0.37~5.5KW,extract capacity:2~7L/S,Limit vacuum:6×10-1Pa。
■Performance Table
Type
off-gas quick result
(L/S)
limited pressure
(Pa)
mating power
(kw)
inner diameter of air inlet
(mm)
noise of vent
(dB)
total weight
(kg)
Shape&size(L×W×H)
(mm)
2X-70
70
6×10-2
5.5
80
≤86
333
91×66×70
2X-30
30
6×10-2
3
65
≤80
230
81×48×57
2X-15
15
6×10-2
2.2
40
≤78
202
79×53×54
2X-8
8
6×10-2
1.1
40
≤76
158
79×43×54
2X-4
4
6×10-2
0.55
25
≤75
66
56×34×40


Q: What are the characteristics of a vertical multistage centrifugal pump?
Vertical multi-stage centrifugal pump is cast iron, the advantage is that the price is cheap, the disadvantage is bulky and power consumption.
Q: What is the pump delivery? What's the difference between years and years?
First of all, as a student majoring in insurance, I strongly condemn the first floor of ignoring practice and trampling on real knowledge!!The insurance industry criticized a lot, but it is required for many people, we should face and try to maintain the healthy development of the industry, the first floor of the insurance you have not done, have no contact with the insurance, insurance, not to dictate the nonsense, more should not be here misleading!
Q: How is the pump level of submersible sewage pump determined?
Generally as:The bottom elevation of sump sump plus 300 is the water level of pump stopThe top 300 of the sump top elevation is the pump water level
Q: What is the function of the heating pump system for the water pump design?
As the feed water temperature is higher, in the case of non warm pump start, will make the pump body is subject to greater thermal impact; in addition, the flow components with the pump contact heating fast, not contact with water directly heating slowly. This expansion due to uneven speed, it will inevitably produce thermal stress, deformation of the pump body, sealing surface, the joint surface is lax and leaking phenomenon. Therefore, the warm water pump system is designed for the water pump.
Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q: Is the sewage pump the same as the mud pump?
No. the main functions are different:1, pump two main performance parameters is the displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement
Q: Suction stroke and lift of water pump
For example: there is a kind of water pump, the model is called "BSP" series, the volume is not large, but the nominal suction process can be 4 meters, it can not add water to 4 meters, it is considered to be relatively high in the micro pumpIn micro pumps, not all pumps have self-priming capacity ("suction stroke")Some centrifugal pumps there is no self-priming ability to use must first do add water. Although some micro pump with self absorption capacity, but "suction" are often the subject of "and the water inlet pipe in all air, can smoke the vertical height of water gap, even only half not so. The pump selection, the absorption process is a relatively important parameter.
Q: What's the word "pump"? Is that what advocates mean?RT
The words should be decided by the object that everyone supports. The supporters are called "fans"; those who support the singers are called "fans"; the people who support "stars" are called "fans". If the idol supported by everybody is called "shadow" and "view",Star of song? It can not be called "what fans", can only be called "fans"!
Q: What is the cause of the damage of pump bearings?
Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
Q: What is a vacuum pump for?
You are not confused by different names. It is mainly used in folding machines, paper cutting machines and water treatment aeration

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products