WQK(V) Sewage Submersible Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery
Packaging Detail: | Wooden packaging |
Delivery Detail: | Within 20days after receipt of your order payment |
Specifications
1.Submersion depth 5m
2.Head up to 35m
3.Flow rate up to 1800L/min
4.Passage of suspended solid up to 35mm
Range of Performance
Flow rate up to 1800L/min(108m3/h)
Head up to 35m
Application and Installation
They are recommended for draining dirty water and sewage in the domestic and civil sectors. Being equipped with a single-channel impeller, they are allowed to pump liquids containing suspended solid bodies with dimensions up to 35 mm and short fibres. They are ideal for pumping drainage water, sewage or waste water for a single dwelling, and for clearing surface or nuisance water. These pumps are outstanding in their reliability in fixed installations with automatic operation.
Operating Conditions
Submersion depth 5m
Liquid temperature up to +40oC
Ambient temperature up to +40oC
Max. Working pressure: 6 bar
Passage of suspended solid up to 35mm
Structure Feature
Pump body: Cast iron
Motor bracket: Cast iron
Impeller: Cast iron
Motor shaft: SS 420 or CS 45#
Mechanical seal: Ceramic - Graphite, Silicon carbide-Carbide alloy
Electric motor: Single-phase 220V - 50Hz with capacitor and thermal overload protector, three phases
380V -50Hz, Voltage fluctuation for 10% more or less is allowed and other voltage for 60Hz is also available.
Insulation: Class E
Protection: IPX8
- Q: What is the minimum continuous flow of a pump?
- Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
- Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
- High speed rotating impeller blade drives the liquid to rotate, and the liquid is thrown out so as to achieve the purpose of conveying. There are many medium for transportation, such as oil, water, chemicals and so on. The pump shaft and the motor shaft are of the same shaft, the pump and the motor are made into an integral body and immersed in water. The medium of transportation is water.
- Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
- The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
- Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
- The unit of displacement is the milliliter. How many milliliters does the pump rotate per circle? The displacement is the pump, the individual,The unit of flow is generally a liter, a figure added to the displacement of the pump over a period of time,
- Q: How many kilograms of water pump are there in the automatic washing machine on the market?
- High pressure pump pressure can reach 4--8kg, flow 5 liters, work current 4 or so.
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
- Q: How many pumps does the 80cm tank use?
- For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
- Q: What are the main performance parameters of the pump?
- RPM revolutions per minute. In N, the unit is R / minThe power delivered by the shaft power prime mover to the pump shaft. In P, the unit is kW.The ratio of useful power to shaft power of an efficient pump. With ETA said. It is an indicator of the degree of perfection of the pump in terms of hydraulic power
- Q: Which nuclear submarines use the shaftless pump technology?
- Shaftless pumping technology and Simulation of shark skin technology are all the next generation of submarine propulsion technology. At present, there is no submarine in the world.
- Q: What is the cause of the damage of pump bearings?
- In high-speed equipment, the most likely damage to bearings is high temperature.
Send your message to us
WQK(V) Sewage Submersible Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches