• WQ Submersible Sewage Pumps System 1
WQ Submersible Sewage Pumps

WQ Submersible Sewage Pumps

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Production Introduction:
WQ blockage-free sewage submersible pump(hereinafter as pump) is untegrative motor and pump. Which is manufactured based on absorbing domestic and foreignadvanced technology and advantages. Impeller, designed with hydraulic model and made by precision casting, has the advantages of energy-saving, anti-winding and non-clogging,etc. At the same time, the pumps have a unique effect in the carriage of solid particles and long fibers garbage. Single or dual impeller structure ensures the pump has the higher efficiency when it has bigger flow. So this king of pump is a ideal drainage pumps for industries and cities.

Application:
1. Living waste water discharging
2.Sewage system of municipal works
3.Sewage system in factory and mine corporation
4.Other transportation of none orrosive and diluted medium
5.Temporary floodwater discharging
6.Waste water discharging of public facility
7.Various waterd is chharging system

Work Conditions:
1.Capacity scope:2-1500m³h;
2.System pressure:≤0.6mpa;
3.Medium consistency:≤1.3x10³kg/m³
4.Motor insulation class:IP68;
5.Rotation:clockwise rotation viewed from motor;
6.Rated Speed:970-2900r/min;
7.Head scope: 3-45;
8.Medium temperature:-15℃-+60℃;
9.Medium PH scope:5-9;
10.Motor insulation class:E Grode;



Model
Flow
(m³/h)
Head
(m)
Voltage
(v)
Pipe size
(mm)
V180
5
7
220
40 32 35
V250
5
7.5
220
40 32 35
V370
5
7.5
220
40 32 35
V450
6
8.5
220/380
50
V550
7
8.5
220/380
50
V750
10
12
220/380
50
7
12
220/380
50
V1100
10
14
220/380
50
16
9
220/380
50
V1300D
18
12
220/380
50
V1500
6
23
220/380
40
V2200
30
17
220/380
80



Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q: How about the depreciation of vacuum pumps?
(three) appliances, tools, furniture and so on related to the production and operation activities, for 5 years;(four) aircraft, trains, ships and other means of transport for 4 years;
Q: How to select metering pump head?
When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.
Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
15MPa. 20MPa means that if you enter the 20MPa, the variable mechanism will work, and the flow at this time automatically matches the load. 20MPa used to supply the fuel by maximum displacement.
Q: What are the basic technical parameters of the pump?
Two, pump head H head is the unit weight of the liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid. Habits referred to as meters. Three, the pump speed is n RPM pump unit time revolutions, represented by the symbol n, the unit is r/min. four, the pump NPSH NPSH NPSH is also called net positive suction head, said main parameters of cavitation performance. Cavitation has been used a h power of five, the power of the pump. And the efficiency of the pump is usually refers to the input power, which is the prime mover on the pump shaft power, it is also known as the shaft power, denoted by P;
Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
Q: What is the cause of the damage of pump bearings?
Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
Q: What does "dual purpose" of water pump mean? Please expert advice
In order to ensure safe and continuous operation, three pumps usually need two units and run one standby.Precautions for using pumps1, if there is any small water pump failure, remember not to work. If the pump shaft packing end wear should be added in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller.
Q: Attention should be paid to the use of pumps?
1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.
Q: How to calculate the motor power of metering pump?
The motor power of the metering pump is divided into two parts1. mechanical power, this part of the power metering pump design part will be some data, mainly to control the mechanical structure of the metering pump required power

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords