Product Description:

All details for WQ Series Sewage Submersible Pump:

 

1. Product Introduction of WQ series Sewage Submersible Pump

WQ series submersible sewage pump is mainly used for municipal work, industrial building, hotels, hospitals, civil air defense, mines, etc. It can be widely used in transfer waste water, rainwater and living water etc. which contains solid grains and various long fibers CNBM WQ series sewage submersible pump have many advantages, such as, hi-efficiency, circumvolution proof, blockage free, auto-coupling, hi-reliability and auto-control, etc.

 

2. Technical Performance of WQ series Sewage Submersible Pump

Discharge diameter: 50~600 mm

Capacity: 10~8000m³/h

Head: 5~60m

Power: 1.5~315kw

Diameter of pass solids: 20~145mm

 

3. Operation Condition of WQ Series Sewage Submersible Pump 

1). Rated Voltage: 380V(660V), Frequency: 50Hz, 3-phase AC.

2). Temperature of medium under 40ºC.

3). PH value: 4~10.

4). Volume ratio of solid in medium below 2%.

5). Density of medium should be lower than 12000kg/m³.

 

4. Structure Characteristic of WQ Series Sewage Submersible Pump

WQ series submersible sewage pump is equipped with status indicator and protection device to ensure for pump safe and reliable operating.

1). The unique cable airproof is adopted, avoid leakage of cable.

2).  Heat protector in stator assure of operating life of the motor.

3).  The pump adopts outer recycling cooling design with motor power more than 18.5kw, which can keep the pump operating safely under the lowest water level.

4).  A floating switch is installed at the bottom of motor chamber to protect the mechanical seal in the motor side.

5).  The oil-water probe is installed at the up end of the oil chamber between pump and motor that can protect the mechanical seal in the side. If leakage occurs, the system will signalize and start protection.

6).  Adopt perfect mechanical seal, the sealing material adopt tungsten carbide, silicon carbide and hard metal alloy, which can prevent the water from entering into the motor, and keep the operating reliable and safety.

7).  The auxiliary impeller can balance the pressure outside of the mechanical seal, prevent the water entering into the oil chamber and prolong the life of the motor.

8).  Unique impeller design, wide passage allow large solid and long fiber passing through freely, it features non-clog, convolve-proof and good passing ability.

9).  The changeable wearing ring is installed between the impeller and the volute to keep the optimum operation conditions.

 

5. Impeller Design Characteristics of WQ Series Sewage Submersible Pump

For the feculence pass freely, it must be widen the flowing passage of impeller, for the big pump, can used for double-vane, or three-vane, for the small pump, it used for single(double) flowing passage, like a bent pipe has same section, it has a good passing characteristic, avoid stop, convolve caused by slowing current possibly. The especially flowing passage of impeller, cooperate with logical volute, made the paper, soft goods, garbage bag and other material in sewage can passing freely and the pump have no vibration in the course of running-in and load through the impeller balance between dynamic and static state.

 

6. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.



WQ Sewage Submersible Centrifugal Pumps with High Quality


WQ Sewage Submersible Centrifugal Pumps with High Quality




Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
That is impossible. The suction height of the pump is caused by the centrifugal force of the vacuum. The water is sucked into the vacuum
Q: Pump unloading in hydraulic transmission,
Can be used for short-term shutdown, pump non-stopNo unloading, usually through the overflow valve back to the tank, high pressure, power, at this time insurable pressure, and so on
Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
The function of vacuum pump is to make vacuum, which has many kinds of structure, such as centrifugal, diaphragm (diaphragm), piston, liquid ring, rotary plate, jet type...................
Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
Q: Does the reservoir water heater press the booster pump (high marks)?
The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
Q: What is the pump delivery? What's the difference between years and years?
First of all, as a student majoring in insurance, I strongly condemn the first floor of ignoring practice and trampling on real knowledge!!The insurance industry criticized a lot, but it is required for many people, we should face and try to maintain the healthy development of the industry, the first floor of the insurance you have not done, have no contact with the insurance, insurance, not to dictate the nonsense, more should not be here misleading!
Q: Water pump does not produce water, what are the reasons?
1 check whether the motor is reversed.2, to see whether the export, the entrance blocked, the outlet pressure gauge whether there is pressure.3, whether the pump selection is wrong, you can not suck up the water.
Q: What do you mean by the self coupling device on the pump?
Auto is an installation of the pump, which comprises a pedestal, self coupling frame, a guide rod and a guide rod support, the bottom fixed coupling frame, vertical installation of two guide rods can easily be brought down without installing the pump, the pump at the bottom of the pool, the outlet of the pump and the discharge tube can automatically lock, don't need to bolt connection, automatic coupling position, so as to achieve the effect of simple and convenient. When you need to repair, pump the pump up without jumping into the sink.
Q: How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.
Q: Significance of water pump model ISO50-160
Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.