• WQ Series Submersible Centrifugal Sewage Pumps With high performacne System 1
  • WQ Series Submersible Centrifugal Sewage Pumps With high performacne System 2
  • WQ Series Submersible Centrifugal Sewage Pumps With high performacne System 3
WQ Series Submersible Centrifugal Sewage Pumps With high performacne

WQ Series Submersible Centrifugal Sewage Pumps With high performacne

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

Product outline
WQ series submersible sewage pump absorbs the advantages with the same products made abroad and at home, holds a comprehensive optimized design on its hydraulic model, mechanical structure,sealing, cooling, protection, control etc. points, features a good performance in discharging solids and in the prevention of fiber wrapping, high efficiency and energy-saving, strong reliability and, equipped with a specially developed electric control cabinet, not only the auto-control can be realized but also the motor can be made sure to work safely and reliably.Available with various types of installation to simplify the pump station and save the investment.
WQ series submersible sewage pump is mainly used for the municipal works, buildings, industrial sewage and sewage treatment to discharge the sewage, waste water and rainwater containing solids and long fibers.
Characteristic and advantage
1. Most of the impellers with the pump of an aperture below 400 come as a bi-runner impeller and few of them is a multi-blade centrifugal impeller. While most of the impellers with the pump of an aperture 400 and above come as a mixed flow impeller and few of them is a bi-runner impeller. The spacious pump casing runner lets the solids easily passing and the fibers uneasily wrapping so that it is most suitable for discharging sewage and dirt.
2. Two independent single end-face mechanical seals are in-series mounted, with the installation mode as the internal installation mode, and, compared with the external installation mode, the medium is more uneasy to leak and also its sealing friction pair are easier lubricated by the oil in the oil chamber. A special spiral slot or a small seam is used to resist the solid
grains to be deposited on the mechanical seal by the pump to make sure of its stable work. The unique mechanical seal layout mode and bearing combination makes the suspension arm of the shaft short, a heavy rigidity and a small jump, more benefit for reducing the leak from the mechanical seal and extending the life of it.
3. The motor of a protective grade IPX8 works in submerged mode and holds the best cooling effect. The grade F insulation makes the winding bearable to a higher temperature and, compared with common motors, more durable.
4. The perfect combination of the special electric control cabinet, the liquid level floating-ball switch and the protective components carries out the automatic monitor and alarm for
water leak and winding overheat, the protections at shortcircuit, overload, lack-of-phase and voltage-lost cut-off, the accurately auto-controls of start, stop, alternation and minimum
submerged depth of the pump, without need of special persons for looking-after, option at will is available between the selfcoupled reducing start and electronic soft start. All of these
makes sure of safe and reliable use of the pump without any worry.
5. Both motor and hydraulic parts are directly linked together, without need of turning the shaft for centering, easily disassembled and assembled to save the time, benefit for the
site maintenance, reducing the stopped time, saving the cost of repair; simple and compact structure leaves a small volume, only simple lifting equipment is needed, as a special lifting
handler is set on the pump; less land area and the pump can be placed directly in the sewage pond, without need of a special pump house, and the therefore the construction investment
can be saved by over 40.
6. Available with five installation modes for you to choose: auto-coupled, movable hard-pipe, movable soft-pipe, fixed wet type and fixed dry type installation modes.The auto-coupled installation means the connection between the pump and the water-out pipeline is made with the water outlet pipe seat of the auto-coupling, without use of the common fasteners, and, when to separate the pump from the water outlet pipe seat, just place it down along with the guide rod and then lift it, simply enough to get free from worry and trouble and save time.
The submersible sewage pump in the fixed dry type installation not only can replace the old vertical sewage pump but also does not fear of flood submersion, so there is no need of a separate flood-proof facility, benefit for lowering the cost of construction.


Q: How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
Water ring vacuum pump is divided into many types, different sizes, different types, so water is different. As for how much water the no fixed amount, but to ensure that the water temperature is in 25 degrees, not more than 35 degrees can be.
Q: Why can the centrifugal pump hold down the pressure?
The pump before starting to pump shell and the water pipe filled with water, and then start the motor, the pump shaft to drive the impeller and water do high-speed rotation, centrifugal water movement, was thrown to the outer edge of the impeller, the pressure water pipeline flow through the volute pump into the pump shell.
Q: Operating procedures for measuring pumps
start-up1. Adjust the stroke indication to zero by adjusting the nut or handle with the rotary stroke.2 open the outlet valve.3. Open the inlet valve, pump, exhaust from the high point, exhaust from the relief valve, the breather valve.4, point motor, check the operation of the pump.5. Start the motor.6, without pressure on the premise, every 15 minutes to improve the stroke 20%, if there is no pressure, do not substantially improve the stroke.Note: (1) whether the sound or vibration of the pump is abnormal (2), whether the stroke adjustment is automatic or not
Q: What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;
Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
The contact is burned out, the bond and so on the accident, therefore closes the outlet valve, starts the electric machinery, at this time the electric machinery belongs to the no-load current movement, greatly reduces the big current impact
Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
7., master the knowledge of concrete mix ratio, strictly forbid to add water to the pump at will.8., concrete mixing and workability, gravel diameter is too large, effectively refuse to pump.9. when the delivery pump fails, it can analyze the cause and quickly eliminate the trouble.10. pump complete, you must clean the pump body and pressure pipe residual.11. complete other temporary work assigned by the leader.
Q: What is the pumping property of concrete?
Pumping capacity means that fresh concrete can be transported by concrete pump, and concrete construction can be carried out with high efficiency. 'pumping' is a qualitative statement
Q: The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q: How to calculate the motor power of metering pump?
The motor power of the metering pump is divided into two parts1. mechanical power, this part of the power metering pump design part will be some data, mainly to control the mechanical structure of the metering pump required power

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches