• WQ series Submersible Centrifugal Sewage Pump with high performacne System 1
  • WQ series Submersible Centrifugal Sewage Pump with high performacne System 2
  • WQ series Submersible Centrifugal Sewage Pump with high performacne System 3
WQ series Submersible Centrifugal Sewage Pump with high performacne

WQ series Submersible Centrifugal Sewage Pump with high performacne

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

Product outline
WQ series submersible sewage pump absorbs the advantages with the same products made abroad and at home, holds a comprehensive optimized design on its hydraulic model, mechanical structure,sealing, cooling, protection, control etc. points, features a good performance in discharging solids and in the prevention of fiber wrapping, high efficiency and energy-saving, strong reliability and, equipped with a specially developed electric control cabinet, not only the auto-control can be realized but also the motor can be made sure to work safely and reliably.Available with various types of installation to simplify the pump station and save the investment.
WQ series submersible sewage pump is mainly used for the municipal works, buildings, industrial sewage and sewage treatment to discharge the sewage, waste water and rainwater containing solids and long fibers.
Characteristic and advantage
1. Most of the impellers with the pump of an aperture below 400 come as a bi-runner impeller and few of them is a multi-blade centrifugal impeller. While most of the impellers with the pump of an aperture 400 and above come as a mixed flow impeller and few of them is a bi-runner impeller. The spacious pump casing runner lets the solids easily passing and the fibers uneasily wrapping so that it is most suitable for discharging sewage and dirt.
2. Two independent single end-face mechanical seals are in-series mounted, with the installation mode as the internal installation mode, and, compared with the external installation mode, the medium is more uneasy to leak and also its sealing friction pair are easier lubricated by the oil in the oil chamber. A special spiral slot or a small seam is used to resist the solid
grains to be deposited on the mechanical seal by the pump to make sure of its stable work. The unique mechanical seal layout mode and bearing combination makes the suspension arm of the shaft short, a heavy rigidity and a small jump, more benefit for reducing the leak from the mechanical seal and extending the life of it.
3. The motor of a protective grade IPX8 works in submerged mode and holds the best cooling effect. The grade F insulation makes the winding bearable to a higher temperature and, compared with common motors, more durable.
4. The perfect combination of the special electric control cabinet, the liquid level floating-ball switch and the protective components carries out the automatic monitor and alarm for
water leak and winding overheat, the protections at shortcircuit, overload, lack-of-phase and voltage-lost cut-off, the accurately auto-controls of start, stop, alternation and minimum
submerged depth of the pump, without need of special persons for looking-after, option at will is available between the selfcoupled reducing start and electronic soft start. All of these
makes sure of safe and reliable use of the pump without any worry.
5. Both motor and hydraulic parts are directly linked together, without need of turning the shaft for centering, easily disassembled and assembled to save the time, benefit for the
site maintenance, reducing the stopped time, saving the cost of repair; simple and compact structure leaves a small volume, only simple lifting equipment is needed, as a special lifting
handler is set on the pump; less land area and the pump can be placed directly in the sewage pond, without need of a special pump house, and the therefore the construction investment
can be saved by over 40.
6. Available with five installation modes for you to choose: auto-coupled, movable hard-pipe, movable soft-pipe, fixed wet type and fixed dry type installation modes.The auto-coupled installation means the connection between the pump and the water-out pipeline is made with the water outlet pipe seat of the auto-coupling, without use of the common fasteners, and, when to separate the pump from the water outlet pipe seat, just place it down along with the guide rod and then lift it, simply enough to get free from worry and trouble and save time.
The submersible sewage pump in the fixed dry type installation not only can replace the old vertical sewage pump but also does not fear of flood submersion, so there is no need of a separate flood-proof facility, benefit for lowering the cost of construction.


Q: Piston filling and peristaltic pump filling which precision is high?
First of all, we should know the working principle of each, and analyze the accuracy from the principle, this problem is very important. Piston filling, such as the injection of drugs that we have been ill, the accuracy of the piston pump depends on the accuracy of the motor and the area of the unit cross section
Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
Q: Concrete pump 125 pipe wall thickness
Currently mainly divided into gate valve, concrete pump and S valve concrete pump. Another is a pump consisting of a pump body mounted on an automobile chassis and fitted with retractable or bent cloth poles
Q: Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q: Does the reservoir water heater press the booster pump (high marks)?
60 liters of water storage should be able to drive two bathrooms at the same time bath! Water storage water heater generally does not need booster pump, as long as there is a little pressure, the water heater is filled with water, as long as the tap water can do. You can turn off the hot water valve and see only the amount of water in the cold water. If hot water is much smaller than cold water, it is the reason for the heater. Can you check the water mixer is normal, the one-way valve is installed in reverse.
Q: What's the difference between non negative pressure and variable frequency water pump?
When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
Q: Water pump does not produce water, what are the reasons?
4. as a water inlet valve, check whether it is normal, whether the silted up.5. the installation height of water pump exceeds the allowable suction height of pump, or the suction pipe is too long.
Q: What is the liquid pump? What are their categories? What are their strengths and weaknesses?
The liquid pump can be filled with oil, water and chemical medium. The gas drive range of the liquid pump is 1 to 10bar (14.5-145psi). The bottom piston is controlled by a two position four pass pilot valve.
Q: What is the pumping property of concrete?
Pumpable concrete slump is generally greater than 160mm, the mortar content is too low, the maximum aggregate size of not more than 1/3 of the diameter of the pump pipe, sending process segregation, plugging in the pump.
Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
If the water pressure is not enough, the pump can not start, then it must be wrong. Because if the water pressure is not enough, the pump should be running automatically. It's just because the water pressure is not enough.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches