• Vertical Tubine Water Pump for Agriculture System 1
  • Vertical Tubine Water Pump for Agriculture System 2
  • Vertical Tubine Water Pump for Agriculture System 3
Vertical Tubine Water Pump for Agriculture

Vertical Tubine Water Pump for Agriculture

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 Centrifugal Water Pump for Agriculture Application

1.Structure of  Centrifugal Water Pump Description

 

Centrifugal Water Pump is used for transporting pure water or liquids with physical and chemical  properties similar to pure water, and the maximum of the medium temperature is 80°C.(type ISR pump reaches 120°C). Widely applied towater supply industry, urban water supply and drainage, metallurgy, power stations, textile, chemical industry, printing and dyeing, ceramics, rubber, heating, waste heat utilization, air conditioning, agricultural irrigation and etc.

 

2.Main Features of the Centrifugal Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Centrifugal Water Pump images

Vertical Tubine Water Pump for Agriculture

4. Centrifugal Water Pump Specification

 

Item

Diesel Water Pump

Diesel Pump

Agricultural Irrigation Desel Water Pump

Model

IS

Material

Cast iron

Mode

Horizontal

Color

Blue and adjustable

Theory

Centrifugal Pump

Structure

Single-stage Pump

Usage

water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

High Pressure

Application

Transporting pure water or liquids

Outlet Diameter

32-250mm

Capacity

6.3-400m3/h

Head

5-125m

Rotation Speed

1450-2900r/min

Power

0.55-110kW

Warrenty

1 Year

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

 

Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
1) oil rotary vane vacuum pump is too low, no effect on the oil seal exhaust valve, rotary plug to refuel after large exhaust sound, and oil mist, that the level is too low, the gas can be eliminated.(2) the vacuum caused by the condensable steam pollution of oil should be changed, and new vacuum pump oil should be replaced.
Q: What are the internal losses in centrifugal pumps? How did they come about?
Due to the friction of the bearing, the friction in the stuffing box, and the losses caused by the rotation of the impeller (the loss of the roulette wheel);
Q: How many millimeters is the diameter of the water outlet of the four inch pump?
This question is of no practical significance. The user does not care about this figure. The concern should be the nominal diameter, which is fitted with flanges and pipes. Moreover, the pump shell is cast iron, the inside diameter is not processed, and there is no matching parts, there is only one manufacturing size.
Q: What are the causes of pump shock?
Troubleshooting cause1. bearing damage, replace new bearings2., coupling pin, bolt damage, rubber column or metal bolt wear, change
Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
Multi line linkage NHBVR-4*1.5 is a positive pressure blower and smoke exhaust machine fire fighting equipment
Q: What are the main performance parameters of hydraulic pumps?
Main performance parameters of hydraulic pump:1. Hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q: How can I buy a pump?
Selection principle of pump:1, so that the selected pump type and performance parameters meet the unit flow, lift, pressure, temperature and other requirements, the most important thing is to determine the voltage, the maximum lift, and when the head high reached much traffic.
Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
The air pump.The pump itself is mechanical failure.The pump outlet valve core off.Low voltage power.
Q: What are the main performance parameters of the pump?
The amount of liquid supplied by a pump in unit time. Volume flow Q, unit m3 / s. There is mass flow G, unit is kg / s.
Q: What is the difference between centrifugal pump and self suction pump? Which is better?
If the centrifugal pump in full before the start of the shell of the gas, then start after the center of the impeller was thrown in the gas can not be large enough to form the vacuum, so that liquid in the bath can not be sucked, so the centrifugal pump to start before using foreign liquid in the pump housing space filling

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords