• Solid Wooden Composite Door for Decoration System 1
  • Solid Wooden Composite Door for Decoration System 2
  • Solid Wooden Composite Door for Decoration System 3
Solid Wooden Composite Door for Decoration

Solid Wooden Composite Door for Decoration

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
2000 m²
Supply Capability:
200000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Solid Wood Composite Door

 

1, Door Leaf

 

1) HDF or MDF moulded panel door skins on face and back;

 

2) Finger joint;

 

3) Inside material: Honeycomb/Chipboard/Solid wood/wood skeleton

 

4) Finishes: white promer coating/engineer veneer/natural wood veneer/PVC film coating

 

5) Density & Moisture: depending on environments

 

2, Fram

 

1) MDF, wooden veneer

 

2) Dimensions depend on the wall thickness

 

3, Architrave:

 

Solid wood or MDF, wood veneer

 

4, Standard size: 2000 * 800 * 40 mm

 

Also custom-made acceptable, within the following limits:

 

Height: 1850 --- 2150 mm

 

Width: 660 ---- 900 mm

 

Thickness: 35 --- 45 mm

 

5, Loading quantity:

 

Door leaf loading quantity:

 

whole set:

 

20 GP: 200 sets ( more or less )

 

40 GP: 380 sets ( more or less )

 

6, OEM & ODM is available





 


Q: What is the difference between a framed glass automatic door and a pure glass automatic door?
Automatic door sensors, of course, easy to use, select Sean automatic doors, our company's door is also used in this brand Sean's door in the price of the service are very advantages
Q: I need to ask access control one machine control sensor door, why will there be sensor door terminal with a voltage? One group is 12v a group is 24v
Single door access control machine automatic door use: single door access control machine Whether it is simple card is still a single door attendance access control system, wiring method, find the access control machine +12 V and PUSH terminal, the two terminal leads to Relay power input, and then the relay output signal terminals where the NO and COM two leads connected to the automatic door sensor signal line input terminal, then access control one machine and automatic doors can be linked, and the external relay more Reliable and safe. For example: a customer requirements automatic door access in the working hours 8: 00-18: 00 people one to the door, automatic doors automatically open, non-working hours, need a legitimate person to open the card door. Implementation: automatic doors do not change before , The door outside the infrared sensor head has four lines connected to the automatic door control department, which has two power lines to the infrared sensor head power supply, do not move them.The other two are the switch signal line, cut off one, cut off, one access Controller COM, a head of the access control controller NO, (note: COM side not to +12.) And the above method of the first method used in parallel, you can meet the customer required time control. If the settings are completed, the following exception: the automatic door opened half of the immediately closed, or closed half and opened. ???Access control controller type access control automatic sensor door, the realization of the method: a single door bi-directional access control controller as an example, the access controller relay output COM and NO connected to the automatic door sensor signal input terminal, if COM is connected Power, please remove in advance, this must pay attention. 51 Forum contains a large number of security knowledge of the literature for reference, I hope my answer to your question to help ~
Q: I have always wondered why we have invented automatic doors and used them because it would be a lot more work to do to fit them in and make them and all they do is open by themselves.
Most questions that start with Why have an economic component, and this is no exception. Automatic doors enable people to get in and out of a building quickly and easily. They also keep heat and air conditioning inside the building much more efficiently than manual doors, which, when you have a lot of foot traffic or you are in an extreme climate can mean significant energy savings. Retail stores want to make their outlets as user friendly as possible, and that often means larger and more versatile shopping carts. Anything that enables customers to buy more merchandise is a positive for the store, and large, automatic doors that open and close quickly is a part of that. There's also an insurance and liability aspect to automatic doors because no one is likely to have their hand or face slammed by a poorly adjusted manual door. Part of my commute every day is through Union Station in Chicago and the doors there are not automatic - there is a constant danger of them slamming on the fingers of the unaware. Automatic doors are impervious to wind and also enable businesses and civic buildings to comply with the Americans With Disabilities Act, which states that people who may have physical or other challenges easy access. Really large buildings, like airport terminals often have automatic revolving doors which allow huge numbers of people access with luggage in an efficient manner while also cutting down on heating and cooling costs.
Q: Can the fire door be replaced by an electric door?
Need to fire department approval, shall not arbitrarily change and move the fire facilities
Q: 12-volt access control and 24-volt Panasonic automatic door machine wiring
12 volt access to the current you first find, and then borrow one of the open signal points to control the 24V Panasonic automatic door machine system. This may need to be modified according to the situation to install the circuit. Plus a 12V miniature relay can be used. I have transformed a similar system.
Q: What is the design principle of the automatic credit card?
Yes! Upstairs to answer the easy to understand! I will not say more! How do you want to install automatic doors! Swipe open the door can also add a lot of features! Such as a fixed time can swipe open the door! After a time on the card can not open ah! Can be set up!
Q: Automatic door remote control The composition of the automatic door remote control system
The transmitter part is generally divided into two types, namely, remote control and transmitter module, remote control and remote control module is for the use of the way, the remote control can be used as a whole machine, the external leads have wiring pile head; Module in the circuit When a component is used and is applied according to its pin definition, the advantage of using the remote control module is that it can be seamlessly connected to the application circuit, with a small size, low price, and the user must really understand the circuit principle. With the remote control to the convenience. Receiving part is generally divided into two types, namely, superheterodyne and super-regenerative receiver, super regenerative demodulation circuit, also known as super-regenerative detection circuit, it is actually working in the intermittent oscillation state of the regenerative detection circuit. Superheterodyne demodulation circuit and superheterodyne radio the same, it is set up a local oscillation circuit to generate oscillation signal, and received the carrier frequency signal mixing, the IF (usually 465kHz) signal, the intermediate frequency amplification and Detect, demodulate the data signal. Since the carrier frequency is fixed, the circuit is simpler than the radio. Superheterodyne receiver is stable, high sensitivity, anti-interference ability is relatively good; super-regenerative receiver small size, cheap.
Q: How is my world automatic door?
You are talking about the automatic door, I will only use the kind of red stone, viscous piston, red stone torch, pressure plate to do the automatic door, if you can reply to me
Q: Automatic doors can only open the reasons can not be closed
First look at the sensor within the scope of whether there are objects, so that induction radar to the object. Second check the door under the various parts of the door can work properly. Finally, view the next line, excluding the signal transmission caused by the error.
Q: How does the automatic door work?
The automatic door system consists of sensors, controllers, motors, rails and doors. The sensor is now mostly microwave sensors, the equivalent of a radar, when there is a movement near the object, it sends a signal to the controller. Controller is generally used PLC programming microcomputer, we can adjust the controller through the door to open the door when the speed. The controller controls the operation of the motor and the motor is connected to the door by means of a toothed belt and a door connection (connected by a hanging part). There is a pulley on the hanging part. The door is hung on the guide rail by a pulley on the hanging part Can slide. The rails are fixed on the beams and the beams are firmly connected to the walls on both sides. The gravity of the door is supported by the guide rail, and the belt pull door slides left and right on the rail

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches