1.  Description of solar pumps. 

CNBM Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.

 

In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, CNBM Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


CNBM Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

 

2. Technical Features

Solar Water Pump is a pumping device powered by solar energy, consists of a solar pumping inverter and a deep well pump, mainly used for agriculture irrigation, desert control, pasture animal husbandry, city waterscape, seawater desalination, living water supply and so on. And there are lots of excellent advantages with regard the Solar Water Pumps. 

1> Use solar energy, need no connection to grid.         

2> Automatically operation, maintenance free.
3> Easy to install and move, high universality.              

4> Clean and green, high economic benefits.

CNBM solar pump kit also named solar water pumps, solar pond pump, solar borehole pump, solar funtain pumps, solar powered water pump, solar irrigation pump, solar deep well pump, and solar submersible pump.



 3. Specification details. 

1> Flow: Max. 700m³/day. (6 hours total)

2> Head: Max. 290m

3> Power: 0.37Kw~55Kw


 

4. FAQ for Solar Water Pumps. 

1> May we ask if the bare pump or the whole pump system would be all right for you to arrange the delivery?

     The bare pump and the who systems would be all acceptable at your side. A controller will be equipped with the pump freely. Regarding the whole system, we can also make the best solar panels configuration according to your requirements. 

2> Does your controller have the MPPT Function?

     Yes, our controllers have. This would be not a problem. 

3> Can your pump work automatically?

     Yes, it would be the basic advantage of solar water pumps. 



Solar Water Pump Irrigation System With DC and AC

Solar Water Pump Irrigation System With DC and AC

Solar Water Pump Irrigation System With DC and AC




Q: Know flow and lift how to calculate the pump power?
The pump power (kw) ={9.61* flow (cubic meters per second) * head (m)}/.Where ETA is device efficiency, including mechanical, electrical loss and other factors, generally between 55%~80%. The smaller the pump, the lower the efficiency.
Q: Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q: How to install, operate and maintain the pipeline booster pump?
When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
Q: Concrete pump 125 pipe wall thickness
Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
Product featuresThe integrated structure of motor and pump adopts static seal, so that the pump is completely free of leakage;Full closed and no leakage structure, can transport toxic and harmful liquid substances;The shielded water-cooled motor and the cooling fan are removed to make the pump operate in a low noise and quiet condition. The utility model is suitable for occasions with high environmental noise requirements;
Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
Installation method of hydraulic pump(1) according to the technological requirements and the cavitation conditions of the pump, the installation height check and the civil engineering of the foundation are carried out.(2) prepare a series of flat washers and wedge gaskets of different thickness before installation.(3) according to the characteristics of the pump conveying medium, determine the material of the gasket at the connection and process the gasket.
Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
Direct connected pump: pump impeller installed directly on the motor shaft, it looks like a whole, relatively compact, simple installation, but the general power is relatively small (big bad processing connection, but not absolute);Non direct pump: pumps and motors are independent of each other, through the coupling torque transmission, the structure is relatively large, complex installation, to adjust the level / concentricity and so on, the general power is relatively large
Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
If the water pressure is not enough, the pump can not start, then it must be wrong. Because if the water pressure is not enough, the pump should be running automatically. It's just because the water pressure is not enough.
Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q: Attention should be paid to the use of pumps?
7 water pump and pipe interface must be sealed, because if there is debris access, then the pump will cause damage to the interior. 8 for the water pump bearing is also the focus of inspection, use up to check whether the bearings wear,