Single / Three Phase Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description of Single / Three Phase Converter Frequency
Single / Three Phase Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features of Single / Three Phase Converter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure of Single / Three Phase Converter Frequency
Application of Single / Three Phase Converter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance of Single / Three Phase Converter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: In the official website to buy ThinkPad notebook, to the power adapter?
- Where the power adapter to buy the general will be supporting
- Q: How to view the parameters of the notebook power adapter on your computer
- Notebook power adapter using the correct method] 1. Try to avoid the use of outdoor or harsh environments to prevent the adapter is exposed or damp. 2. When you are not using the adapter, please unplug the power plug. Because, for a long time the power will let the adapter has been in working condition, will affect the end of life. 3. Although the adapter is a broadband operating voltage, marked from 100V-240V can be, but if the voltage is extremely unstable in the case of use, the same will cause damage to the power adapter.
- Q: Will the 75KW4 pole motor can be used to increase the speed of the inverter?
- The motor speed is relative, the rated speed is the maximum speed
- Q: Servo control system can give the inverter signal,
- but want two motor synchronization, it should be impossible, the converter does not reflect so fast, and the speed is not so stable.
- Q: 6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
- To 400HZ, so high frequency you tried it? I only tried 80HZ, if you tried, please tell me some of the high frequency of the actual situation will produce some changes in the motor,
- Q: How does the variable frequency motor output torque at very low frequencies?
- Low frequency, the motor torque is relatively low, generally VF inverter performance is good or bad, the price level reflected in this time. But there is torque to enhance the function, it will not move without moving. If no load can not start, check the motor card and other mechanical problems such as whether there is a problem.
- Q: Delta VFD-F frequency converter how to adjust the number of poles
- Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- Frequency conversion frequency f to 90Hz can. 1800 = 60x90 / 3,3 that is 3 pole, is 6 pole. Regardless of load.
- Q: Delta VFD-A frequency converter motor number of poles set
- The frequency parameters of the inverter motor are not set, because the inverter will automatically detect the number of pole pairs of the motor during operation, and it will not need to be set.
- Q: Who knows how the inverter is calculated?
- There is no pole in the inverter, the electrode can be polarized, the greater the number of poles of the motor the slower the speed, please refer to.
1. Manufacturer Overview
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Single / Three Phase Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords