Description of Single / Three Phase Converter Frequency
Single / Three Phase Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features of Single / Three Phase Converter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure of Single / Three Phase Converter Frequency
Application of Single / Three Phase Converter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance of Single / Three Phase Converter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: My Lenovo v450 laptop power adapter should be bad how to match?
- Hello, this is not recommended to go online to buy. The original is too expensive, generally with the domestic voltage instability may occur, so I suggest you go to the computer city to buy. Generally good quality, to about 120. The The As for the model, you can look at the output power, or you take your bad adapter to go, people see a look. The The The You can use a few years no problem, power adapter this kind of thing, online to buy the replacement is not convenient. The Hope to help you
- Q: What is the laptop power adapter? Is it the battery?
- so that the book can be normal operation, or else you think the notebook is 220V Is the voltage at work?
- Q: Laptop power supply 20V 3.5A can use 20V 4.5A power adapter Mody, what impact?
- can. For a constant voltage power adapter, the following requirements can be replaced: The replacement of the new power adapter output voltage is the same as or similar to the output voltage of the original power adapter. Replacement of the new power adapter maximum output current is not less than the original power adapter maximum output current. Replacement of the new power adapter with the original power adapter interface definition and shape the same. Replacement of the new power adapter Other non-major electrical performance indicators, not less than the original power adapter of the corresponding indicators. Notebook original power adapter nominal rated current of 3.5A, indicating that the laptop itself does not exceed the input current of 3.5A, for the rated current of 4.5A power adapter, the drive is no problem in this load.
- Q: Inverter ACS355 If the speed is outside the allowable range, how to set the limit value
- Remember, 2001 this should be set to a negative number, set to a positive number of your speed will never be less than this value.
- Q: How to view your own laptop power adapter is how much tile?
- There are signs on the power adapter, you look for sticky paper to write the voltage and current power. If there is no write power, the direct voltage multiplied by the current is the maximum power.
- Q: With the inverter control fan 37Kw4 pole with what model inverter
- Control the fan: select the fan pump with 37KW or 45KW inverter.
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- Frequency converter in the 5-50Hz is constant torque frequency, 50-100Hz is constant power frequency, to see what you want to get the effect
- Q: HP laptop power adapter how to open
- HP notebook power adapter for the full size of the design, you can follow the following steps to dismantle: 1, notebook computer power adapter for the injection molding package or with a strong adhesive glue, without any screws, so generally only with violence to crack. However, as long as the method properly, after the dismantling of the power adapter can be restored to the original, do not carefully observe almost no traces of open. 2, the power adapter on the side of the side of the white paper, with an electric knife edge along the power adapter between the gap between the cover, and then hit the electric knife with a hammer, so that the electric knife from the adapter between the upper and lower cover go with. In the different positions of the gap between the upper and lower covers of the adapter, use the tip of the electric knife to be scratched along the gap. When the upper and lower covers are first split, the depth of the tool is deep and then the upper and lower covers of the adapter are separated. 3, then open the shell of the power adapter, you can see the adapter circuit outside the package with a copper shield, with a knife to cut the shielding tape on the tape, and then use the soldering iron shield and the internal circuit board connected to the two Solder joints, you can remove the shield. 4, between the shield and the circuit board is also separated by a layer of thick plastic film, and then cut off the knife after the United States, you can see the circuit board "Lushan true"
- Q: How do I select a drive? Which brand is better
- ???4, when the inverter is used to control several motors in parallel, be sure to consider the inverter to the motor cable length of the sum of the inverter in the allowable range. If you exceed the specified value, to enlarge one or two steps to select the inverter. In addition, in this case, the inverter control mode can only be V / F control mode, and the inverter can not protect the motor over-current, overload protection, this time in each motor on the fuse to achieve protection. ????5, for some special applications, such as high ambient temperature, high switching frequency, high altitude, etc., this time will cause the inverter derating, the inverter need to enlarge a file selection. ????6, the use of inverter control high-speed motor, due to high-speed motor reactance small, high harmonics also increase the output current value. Therefore, when selecting a frequency converter for a high-speed motor, it should be slightly larger than the inverter of an ordinary motor. ????7, the inverter for the variable pole motor, should pay full attention to select the inverter capacity, so that the maximum rated current in the inverter rated output current below. In addition, in the operation of the number of pole conversion, you should first stop the motor work, otherwise it will cause the motor idling, bad will cause damage to the inverter.
- Q: The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
- 4, high-speed motor: high-speed motor running process will produce a large number of harmonics, enhance the output current of the inverter, resulting in a lot of heat. Therefore, the inverter selection is also larger than the ordinary one gear. 5, explosion-proof motor: In some mines, oil extraction environment, the frequency conversion system is explosion-proof motor, the choice of inverter should use the explosion-proof function of the inverter, and the inverter placed in a safer place. 6, the degree of protection: for dust, wet applications, inverter selection should pay attention to its protection level. Or choose Ampang letter AMB inverter, the fan can also run in the water. 7, single-phase motor: When the scene using single-phase motor, the inverter useless. 8, variable pole motor: When the field using variable pole motor, the inverter selection should ensure that the maximum operating current should not exceed the rated current of the inverter
1. Manufacturer Overview
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Single / Three Phase Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords