• SERMAC Wear Plate and Cutting Ring with High Quality System 1
  • SERMAC Wear Plate and Cutting Ring with High Quality System 2
  • SERMAC Wear Plate and Cutting Ring with High Quality System 3
SERMAC Wear Plate and Cutting Ring with High Quality

SERMAC Wear Plate and Cutting Ring with High Quality

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Name: SERMAC Wear Plate and Cutting Ring with High Quality

1.        Specification

Size

DN180DN200DN230

Material

tungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany

Lifetime

30,000-80,000cbm

Carbide HRA

> 86

Electrode HRC

> 63

Type

hardfaced, tungsten carbide and 7 shape tungsten carbide

Application

mud pump, shotcrete,trailer and truck mounted concrete pump

Manufacturer with competitive price

2.        Application

Spare parts for mud pump, shotcrete,trailer and truck mounted concrete pump

         3.  Package

Plastic bag and carton box, also according to your requirements

FAQ:

Q1: Why buy Materials & Equipment from OKorder.com?

A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.

Q4: If we can produce SERMAC Wear Plate and Cutting Ring with High Quality according to customers request?

A4: Yes, we can produce SERMAC Wear Plate and Cutting Ring with High Quality according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.

Q5: How to make a quick resolution for after service?

A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.

 

Images: 

 

 

SERMAC Wear Plate and Cutting Ring with High QualitySERMAC Wear Plate and Cutting Ring with High Quality

 

SERMAC Wear Plate and Cutting Ring with High QualitySERMAC Wear Plate and Cutting Ring with High Quality

 

SERMAC Wear Plate and Cutting Ring with High QualitySERMAC Wear Plate and Cutting Ring with High Quality


Q: Know flow and lift how to calculate the pump power?
P: the density of refrigerant, when the working fluid is water, P =1ETA - pump efficiency, can not find desirable value =0.8N=30x (200/3600) x9.81x1/0.8=20.44 = 20 (kW)(that is, 20kW motors)
Q: What is the name of the day pump and ground pump? Specific introduction
People often say "day pump" actually refers to the boom pump, it also has many other name, such as pump, boom pump, concrete pump, concrete pump truck, these words are "day pump".Ground pump, in fact, refers to the pump drag pump. Therefore, to understand the difference between day pump and ground pump is to understand the difference between the boom pump and the tow pump
Q: What are the functions of a disposable infusion pump?
When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
The diaphragm pump and centrifugal pump refer to the structure of the pump, and the vacuum pump means the use of the pump. There is no comparability between them.Centrifugal is the sign of inertia of an object. As the umbrella turns, water droplets move out of the outer edge of the umbrella and are thrown out. This is what is called centrifugal. Centrifugal pump is designed according to this principle. The high speed rotating impeller blade drives the medium to rotate and is thrown out so as to achieve the purpose of conveying.
Q: What is double hydraulic pump?
Two hydraulic pumps installed on one shaft can be connected to increase output flow, and can also be connected to increase output pressure. See how the demand is. The system can change the mode of application at any time.
Q: What are the basic technical parameters of the pump?
The effective power of pump and output power, with Pe said. It is the effective energy per unit time from the pump in conveying out liquid obtained in the pump. Because the lift refers to the effective energy, pump output unit of heavy liquid obtained from the pump so that the product of head and the mass flow rate and the acceleration of gravity. Is to obtain the output from the pump in unit time of liquid effective energy - efficient pump power: Pe= P gQH (W) = QH (W) - P - density of liquid pumping (kg/m3); severe gamma - pump for transporting liquid (N/m3) - Q (pump flow; m3/s; H) - pump head (m); G (m/s2). The acceleration of gravity P axle power and effective power Pe is the difference of power loss in the pump, the size of the pump efficiency to measure the efficiency of the pump. As the effective power and shaft power ratio, with ETA said. Selection of related pumps:
Q: How high can the pneumatic diaphragm pump be?
Pump made of polyvinylidene fluoride (PVDF) material two, the series of pneumatic diaphragm pump belongs to the fluorine plastic pneumatic diaphragm pump is also known as the corrosion products of pneumatic diaphragm pump, diaphragm liquid contact using PTFE material, using PVDF material produced by pneumatic diaphragm pump is mainly used in corrosive the pH, mainly used for chemical liquid conveying multiple solvent, corrosion resistance effect is very good. The series of fluorine plastic pneumatic diaphragm pump in high temperature less than 93.3 degrees.POM pump material also has good resistance to solvent and abrasion resistance, low friction resistance, moisture absorption is also low, the highest temperature of such pumps within 65.5 degreesPolytetrafluoroethylene (PTFE) membrane corrosion resistance is very good, in addition to liquid metal lithium, potassium fluoride, sodium fluoride, three chlorine, three fluoride high temperature oxygen, high flow rate, almost all of the chemical liquid transport (including concentrated nitric acid and aqua regia), PTFE material the maximum temperature to 176.6 degrees. However, for the diaphragm pump product as the diaphragm moves back and forth in work, we suggest that at a temperature of 120 degrees, the prerequisite is the pump body pump must be made of metal material and plastic material. The pump is the pump of PVDF material temperature is highest in less than 93.3 degrees.
Q: Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
Because the characteristic curves of the two are different.The power of centrifugal pump decreases with the decrease of flow rate. When the flow rate is zero, the power is minimum, so the centrifugal pump is started with a closed valve.
Q: Attention should be paid to the use of pumps?
1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.
Q: Significance of water pump model ISO50-160
Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords