Online UPS 10-20KVA

The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.

Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.


Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.


Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.


Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.


High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.


Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1

minute in load of 125-150% . It also has the output short circuit protection capability.


MODELXPC 3110LXPC 3115LXPC 3120L
Rated Power10KVA/8KW15KVA/12KW20KVA/16KW
INPUT
Phase3W+N+G
Input Voltage(207-475)VAC
Input Frequency(46-54)Hz
Input PF>0.95
Bypass voltage(302-437)VAC
OUTPUT
Output Voltage220VAC±1%
Output Power Factor0.8
Output FrequencyNormal mode:same with utility power
Battery mode:49.9~50.1Hz
THDTHD<3% (linear load);THD<5% (non-linear load)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal : 0ms
Overload Capabilityload≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing
105±5%<load≤135±5%:60s
135%≤load≤150±5%:30s >150%:0.1s
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>92%
CommunicationLCD display+RS-232 + Intelligent slot
Restart FunctionAfter turning off due to cut off voltage of battery, UPS will restart
when voltage is in (302~437Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity0~95% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(WXDXH)248×500×616
Weight(kg)273535
Specification is subject to change without prior notice.


Q: How to select the UPS power supply
If a single power supply capacity, can choose the corresponding battery and host. Single power supply can be divided into hot standby power supply and online power supply. The former uses city power normally, and UPS is used in power failure; the latter uses UPS directly, and when UPS fails, it uses city power. The single power supply can also be divided into single and double batteries, the former will decrease the standby power supply during the battery maintenance, the latter will fall by half at most, and the battery maintenance can be divided into automatic and manual maintenance.
Q: I know that UPS is the uninterruptible power supply devices, but EPS seems to be uninterrupted power supply, the difference between the two please master. In addition, other uninterruptible power supply equipment and emergency security system? The most important application in what aspects in the city?
The UPS object is the power supply of computer and network equipment, load characteristics (input power factor) is not very different, so the national standard UPS and EPS power supply output power because the 0.8. object is power protection and fire safety, load properties for inductive and capacitive and rectifier type nonlinear load and the power factor, the output cannot be set to 0.8 (EPS GB will provide its value), and some only work load is stopped after power, thus EPS can provide high impact current, EPS needs better output dynamic characteristic, anti overload ability. Therefore EPS and UPS technology to design the index distribution of each component is different.
Q: What is UPS?
UPS has evolved from the 60s rotary generator to today's intelligent, fully static electronic circuit and continues to develop. At present, UPS generally refers to the static UPS, classified according to its way of work, can be divided into backup, online interactive and online three categories.1. backup type UPS: when the city power is normal, the power supply is directly supplied by the city to the load. When the power supply exceeds the scope of work or the power failure, the power supply is transformed into a battery by inverting the switch. The utility model is characterized in that the structure is simple, the volume is small, and the cost is low, but the input voltage range is narrow, the output voltage is stable, the precision is poor, and the switching time is also available, and the output waveform is generally Fang Bo2. line interactive UPS: in the normal electricity directly by electric power to the load when the power is low or high, through the UPS internal voltage regulator circuit voltage output, when power failure or abnormal, through the switch to battery powered inverter. Its characteristics are: wide input voltage range, low noise, small size and so on, but there is also switching time3. online UPS when power supply is normal, the rectifier provides DC voltage to the inverter by electricity from the inverter to provide AC power load, power anomaly in the city when the inverter powered by battery, the inverter always in working condition, ensure uninterrupted output. The utility model is characterized in that the utility model has the advantages of extremely wide input voltage range, no switching time, stable output voltage and high precision, and is especially suitable for occasions with high power supply requirements, but the cost is higher. At present, UPS with power greater than 3KVA is almost all online UPS
Q: The local voltage I live is not usually very low, only to the voltage to normal at dead of night. Especially at night, the computer keeps restarting or unable to start. I should choose what kind of UPS is better, I just use one of my own computer. Please point out. Don't be too expensive. Just be good enough.
Ups Shenzhen Santak UPS is better than Zhuhai Santak UPSCompared with the battery in good or eight PanasonicUPS Power GuideUPS power supply for everyone is more understanding, that is, through a built-in battery storage of some electrical energy, in the case of power failure to ensure that electrical appliances continue to run for some time. For computer users, the biggest function of UPS power is to protect operating systems and programs from damage due to a sudden power outage, while protecting data that is not stored in time and avoiding loss. In important industries (such as banking, finance, traffic, etc.) and server systems, UPS power supply has a very wide range of applications. Sorry but is either flat or network media reports for the UPS power market are not many, this two days a lot of friends to ask in the end how much money to buy the product, because of differences in product price on the market is too large. In the end there is no guarantee of cheap things, and for this reason, I have done some research on the UPS market, today for you to introduce some information.
Q: Now you need to buy a UPS uninterruptible power supply for emergency after power failure. 2 R910 with 4 1100W power supply (per Taichung 2 of which there are two sets of redundant power supply), T7500 workstation, respectively is Dell and T710, and a MD1200 storage, so there may be a 10kW UPS request can drive all of these machines at the same time, mainly for power for some time to shut down, after the power can be maintained for more than 15 minutes. How do you choose UPS and batteries to meet the demand?
Some of the latest UPS models have multi-mode capabilities, often referred to as' economic models' or 'efficient' models". The UPS generally operates in an efficient mode unless the power condition causes it to switch to a higher protection level dual conversion mode.
Q: Home UPS power insurance burned, ready to change their own insurance, open a look, put the insurance of the plastic have been burned, so they put the insurance shock point line re connected, and replaced with new insurance. The UPS is inserted in the socket by pressing the switch socket UPS back with a pencil, two empty are charged, plug in the appliance does not work. But if you unplug the ups from the mains and plug the socket with the light onto the ups, the lights on the socket are still on. I do not know the electricity, I do not know, I do not understand, I hope that an expert to help answer the question is where, thank you
Poorly described or poorly judged.First of all, don't know your UPS brand and model, anyway, the most effective way is to find the seller, it can be solved.To write you a UPS troubleshooting instructions, "UPS uninterruptible power supply common faults and how to troubleshoot."
Q: How to buy home UPS power
The output stability and instantaneous response ability of on-line UPS are stronger than those of the other two, and the adaptability to nonlinear load and inductive load is also stronger.For some of the more sophisticated equipment, more important equipment and high-end servers, such as the use of online UPS.In some areas with large fluctuations in electricity, avoid interactive and backup.To use a generator with a short delay UPS, an on-line UPS is recommended because the stability of the voltage and frequency of an ordinary generator is poor, and interaction and backup may cause an abnormal operation.Some brands of UPS (online) can not receive motor turn bypass power supply, the purchase should first understand clearly.
Q: Room UPS power purchase program
From the principle of UPS power to choose backup or online?The choice of On-line UPS power or backup UPS power supply should be based on the needs of microcomputer equipment and economic conditions. If the economic condition is good, optional on-line UPS power supply; if the economic condition is poor, but not affect the normal operation of the computer, backup UPS power supply can also be selected. In the use of back-up UPS power supply, special attention should be paid to the switching time of the power supply. The switching time mainly depends on the switching time of the UPS power supply and the switching time of the microcomputer. If the selection is not correct, the computer will stop when the power supply failure, and can not play the role of power supply protection.
Q: Santak uninterruptible power supply DC24V how to use?
How to use the UPS power supply:The three UPS power supply plug inserted into the body with the power plug, open the UPS power switch, UPS power supply to work, then the power line computer host and display the plug into the socket body behind the UPS power supply, one by one to boot.
Q: Dear teacher: I would like to know the use of emergency power supply, so I would like to ask you all about what EPS and UPS power mean What are their respective areas of use? Thank you very much!
Their common place is that there are bypass, inverter, battery charging circuit, which can provide battery inverter emergency power supply when the city electricity is abnormal. The difference is that UPS is very precise, rectifier and inverter double shift work, ensure the output interruption time is less than 10 milliseconds when power (typically 0 milliseconds interrupted, because the inverter has been at work); EPS precision is low, the outage time off time is generally greater than 10 milliseconds, between 10-50ms, if the server, this time breaks more than 20ms will restart.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords