Online UPS 20KVA
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Online UPS 10-20KVA
The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.
Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.
Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.
Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.
Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.
Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1
minute in load of 125-150% . It also has the output short circuit protection capability.
MODEL | XPC 3110L | XPC 3115L | XPC 3120L |
Rated Power | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
INPUT | |||
Phase | 3W+N+G | ||
Input Voltage | (207-475)VAC | ||
Input Frequency | (46-54)Hz | ||
Input PF | >0.95 | ||
Bypass voltage | (302-437)VAC | ||
OUTPUT | |||
Output Voltage | 220VAC±1% | ||
Output Power Factor | 0.8 | ||
Output Frequency | Normal mode:same with utility power Battery mode:49.9~50.1Hz | ||
THD | THD<3% (linear load);THD<5% (non-linear load) | ||
Transfer Time | Normal to battery mode: 0ms Bypass mode to normal : 0ms | ||
Overload Capability | load≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing 105±5%<load≤135±5%:60s 135%≤load≤150±5%:30s >150%:0.1s | ||
BATTERY | |||
Voltage | 192Vdc | ||
Charging voltage | 220Vdc | ||
Overvoltage | 230Vdc | ||
Charging Current | 2A/4A(L type) | ||
SYSTEM | |||
Efficiency | >92% | ||
Communication | LCD display+RS-232 + Intelligent slot | ||
Restart Function | After turning off due to cut off voltage of battery, UPS will restart when voltage is in (302~437Vac) and frequency is in (47~53Hz). | ||
Noise (1m front) | <45dBA | <50dBA | |
Operation Temperature | 0°C to 40°C | ||
Humidity | 0~95% non-condensing | ||
Storage Temperature | -40°C to 50°C | ||
Altitude | 1000m | ||
Dimension(WXDXH) | 248×500×616 | ||
Weight(kg) | 27 | 35 | 35 |
Specification is subject to change without prior notice. |
- Q:UPS what does "uninterruptible power OEM" mean?
- This kind of cooperation with others is called OEM for short, and the manufacturers who undertake processing tasks are called OEM manufacturers, and the products they manufacture are called OEM products. Visible, fixed-point production belongs to the "OEM" in the processing trade. In international trade, it is the export of labor as the carrier of commodities.
- Q:The server is the highest rated power power power 500W power 270W 400W actual computer hardware over time with 12 hard disk so 300W with an optical transceiver to 320W display to unplug the server after power failure in the company of our own and run the web site to prevent power which can maintain 8 hours of running the best server is the 12 hour UPS brand does not need to be too good not to use enough often cut occasionally can be added:
- You still have to use the power of about 320 1KVA UPS, but also with the best use of the battery online, how much more than the backup, you can match Burke HS-1K is this: http://www.gdbaykee /flash/sort082/sort0103/UPS_EPS15.html UPS. But in general a long time, 8 hours to many batteries, a lot of money, are used with the generator UPS to the long time the general people power.
- Q:What does "UPS" and "DPU" mean in power plants?
- DPU (Distributed, Processing, Unit), that is, the decentralized processing unit, is often used in DCS control systems.Explanation: it is a station on WDPF high speed highway. Sometimes, DPU is also known as multi purpose MAC controller (Controller MultiApplication). It can execute the control strategy of engineer configuration, it can realize discrete ladder logic control, and also realize continuous regulation control. DPU can perform more than 70 special functions and more than 150 process control algorithms. In addition, it can realize data acquisition, scale transformation, alarm limit check, operation record, sequence event recording and so on.
- Q:How should the UPS uninterruptible power supply be selected?
- UPS is usually divided into two types: power frequency machine and high frequency machine. The power frequency machine is composed of thyristor, SCR rectifier, IGBT inverter, bypass and power frequency step-up isolation transformer. Because its rectifier and transformer work frequency are all frequency 50Hz, as the name suggests is "power frequency UPS".High frequency machine usually consists of IGBT high-frequency rectifier converter, battery, inverter and bypass, IGBT can control in the gate driver to control the IGBT turn-on and turn off switching frequency IGBT rectifier, usually in a few tens of KHz to K, even up to hundreds of KHz, compared with the 50Hz frequency, called high frequency UPS.With the development of power electronics technology and high frequency power devices. Small and medium power section of UPS products are gradually high frequency, high frequency UPS has power density, small size, light weight characteristics. But in the high frequency UPS power section, the medium to large power transition is pushed forward. The high frequency topology UPS exposes some inherent shortcomings during use and affects the safe use and operation of UPS.
- Q:What about the EAST UPS power supply?
- EAST in the domestic UPS power industry can be regarded as the leading brand. The overall service level and the quality of the UPS power supply are all good. Our company has been used for several years, and nothing has happened yet.
- Q:Is the emergency output voltage of UPS DC or AC?
- UPS output is AC, after the city power cut off, the internal inverter part will convert DC to AC, inverter output, and what do not understand, I have contact information in the data. Hangzhou Bo Hong Electronics Co., Ltd.
- Q:How to correctly use and maintain UPS uninterruptible power supply
- Maintain proper environmental temperature. The important factors affecting the life of the battery is environment temperature, the general requirements of the battery manufacturers best environmental temperature in degrees between 20-25. Although the temperature increases, the battery discharge capacity has improved, but the cost is to shorten the life of the battery. According to the test, once the ambient temperature is over 25 degrees centigrade, the life of the battery will be shortened by half when the temperature is increased by 10 degrees. At present, UPS batteries used are generally maintenance free sealed lead-acid batteries, the design life is generally 3 years, which is required in the battery manufacturer environment to achieve. If the environmental requirements are not met, there will be a great difference in the length of life. In addition, the environmental temperature increased, will lead to enhanced chemical activity inside the cell, resulting in a lot of heat, in turn to the ambient temperature rises, the vicious spiral, will shorten the battery life.
- Q:What does the UPS parameter of the 1500KV power mean?
- This should be 1500VA, which means that the power supply is 1500VA, that is, 1500 watts.UPS (Uninterruptible Power System/Uninterruptible Power Supply), namely, uninterruptible power supply, the battery is (for maintenance free lead-acid batteries) connected with the host, the host through the inverter module circuit of the direct current into power system equipment
- Q:What server UPS power line?
- To configure the appropriate UPS power for your server, it is recommended that you understand the following:1. what is the number and total power of the server?2. what is the required UPS power supply time?Only in this way can I know how much UPS power and batteries are allocated to the server. As for the brand, the domestic can choose EAST, foreign can choose APC, Emerson, but foreign brands to be partial expensive, but after-sales service speed than domestic slow. Therefore, after consideration with after-sales protection, the choice of domestic brands more appropriate
- Q:What is the working principle of the UPS power supply?
- On line staggered online interactive working principleLine interleaving also known as online interactive or online interactive (Line-Interactive UPS), the basic mode of operation and off-line, the difference is that online is not interleaved on-line in the whole power supply, but all the time in the power supply condition monitoring of city electricity, has boost and decompression compensation circuit in the power supply situation, real-time correction electricity is not ideal, and reduce unnecessary "Battery Mode" switch to extend battery life.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS 20KVA
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords