• Online UPS 6KVA System 1
Online UPS 6KVA

Online UPS 6KVA

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Online UPS 6-10KVA

XPC 6-10KVA is new generation UPS, we adopt the latest R&D achievements and applications experience. With advanced DSP digital control technology, it improves performance and system reliability effectively, and achieves higher level of power density and miniaturization. Besides that, to meet all customers individualized needs, as a high-end small power range online UPS. XPC 6-10KVA series can offer highly reliable power for departmental servers, small local area networks, workstations, industrial machines, small medical equipment, and other small precision electronic devices.

Adopt DSP digital control technology
Adopt advanced DSP digital control technology, it improves performance and system reliability effectively, and achieves higher
level of power density and miniaturization.Besides that, it can meet all customers individualized needs, XPC11 series provide many functions and users can configure the function according their needs.

Wide input voltage range
With wide range of input voltage and frequency, ups can supply power even in remote villages and poor power environment. It reduced the frequency of battery discharge so that the battery life can be prolonged.

Perfect protection
The UPS contain I/P and O/P over protection, short voltage protection, overload protection, short-circuit protection, inverter overheat
protection, battery low voltage warning protection and battery overcharge protection, etc. The aboves function make sure the
load works reliably and stably.The ups will turn to bypass when overload alarm.


User Friendly Display and Communication
The LED mimic diagram gives clear indication of real-time status and power flow through the UPS.The large LCD graphical display provides an array of performance parameters, fault information and historical event log that are useful for troubleshooting.The system provides RS232 signals for remote monitoring, and SNMP (optional) for web-based monitoring.

Intelligent battery management
Intelligent battery management technology extend the battery life and make the battery maintenance convieniently.The battery self-testing technology can find battery problem timely.With battery voltage, overcharge protection to maximize the protection of the battery is not damaged.


Abundant Optional
Friendly LED display (standard) or LCD display (optional).
Four kinds of optional cards provide network communication functions (support dry contact, RS232, RS485 and TCP/IP
communication protocols).


ODELXPC 1106XPC 1106LXPC 1110XPC 1110L
Rated Power6KVA/4.8KW10KVA/8KW
INPUT
PhaseL+N+G
Input Voltage(120±5 to 275±5)Vac
Input Frequency(46±0.2 to 54±0.2)Hz
Input PF>0.99
Bypass voltage(187±5 to 253±5)Vac
OUTPUT
Output Voltage220Vac±1%
Output Power Factor0.8
Output FrequencyNormal Mode, same with utility power
Battery mode: 49.9-50.1Hz
THDTHD<3% (linear load); THD<5% (Non-linear)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal mode : 0ms
Overload Capability105±5%<Load<135±5%: 1min to bypass;
135±5%<Load<150±5%: 30s to bypass;
>150±5%: 0.1s to bypass;
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>90%>92%
CommunicationRS-232 + Intelligent Slot
Restart FunctionAfter Turning off due to cut off voltage of battery, UPS will restart
when voltage is in (175±5~285±5Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity095% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(W*D*H mm)248x500x616240x500x460248x500x616240x500x460
Weight(kg)57205921
Specification is subject to change without prior notice.


Q: What is UPS/EPS?
When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power through the inverter conversion method continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware is not damaged. UPS devices usually provide protection against too large voltages and too low voltages.
Q: How long is the battery life of the UPS power supply?
The effect of discharge depth on battery life is also very large:The deeper the discharge depth of the battery is, the less the number of cycles it uses, so deep discharge should be avoided. Although UPS has a battery low potential protection function, the general single battery discharge to about 10.5V, UPS will automatically shut down. However, if the UPS is in light load discharge or no load discharge, it will also cause deep discharge of the battery. The so-called discharge depth refers to the user in the use of batteries in the process, let the battery release capacity accounted for the percentage of its standard capacity
Q: UPS power sounds, what's the matter?
UPS is an uninterruptible power supply, including an energy storage device and an uninterruptible power supply with constant frequency and constant frequency as the main component. Used primarily to provide uninterrupted power supply to a single computer, computer network system, or other power electronic equipment. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power through the inverter conversion method continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware is not damaged. UPS devices usually provide protection against too large voltages and too low voltages.
Q: Ladies and gentlemen, how long will the UPS power supply be available after air separation and power failure? What does it control?
The backup UPS general built-in 4AH or 7AH battery, the standby time is fixed; the standard model of online and interactive online UPS with built-in 7AH battery, there are long-term models with a large capacity battery, the user can set equipped with large capacity battery standby time according to the need to achieve.
Q: The server is the highest rated power power power 500W power 270W 400W actual computer hardware over time with 12 hard disk so 300W with an optical transceiver to 320W display to unplug the server after power failure in the company of our own and run the web site to prevent power which can maintain 8 hours of running the best server is the 12 hour UPS brand does not need to be too good not to use enough often cut occasionally can be added:
500+300+320=1120W can choose 2KVAS UPS power, external 12 12V100AH batteries (can be delayed more than 8 hours), external 18 12V100AH batteries (can delay 12 hours), need to Q me
Q: The data center is equipped with a UPS power supply. Why use a dual power supply?
UPS is limited in time delay, it is necessary to repair in a limited time, restore power supply, or provide manual shutdown time to the data center, which will not result in data loss.
Q: 60 cameras, 4 video distributors, 1 video matrix controllers, 4 hard disk video recorders, one server, 5 22 monitors, 4 cameras
I'll calculate it as a rule:The power CCD camera board in 1 to about 2W, such as infrared camera, infrared lamp power of 2 to 60 cameras ranging from 15W, 10*60=600W estimation;4 Video Splitter 4*5=20W,1 video matrix controllers 300W,4 hard disk recorders are usually around 15W, that is, 15*4=60W,A server dl388 comes with 460W,
Q: Which model is available under full power? What's the price?
The reserve time is short, you read the instructions, then the reference with the battery.Let's see it herePrices range from high to low
Q: Do not know why, the day before using a good, second days, plug in, found that the computer is not connected, UPS on the backup lights have been flashing, and has been "drip" ring. Unplug the ups plug and socket, the computer is energized. Is it UPS or something?.
BACKUP light flashes, stands for UPS, currently works in backup mode (battery discharge), other lights are not bright, may be UPS without city power input or city power abnormal.
Q: How about the UPS power capacity?
The utility of UPS charging and common UPS battery battery standard, the configuration of the 100AH, 65AH, 38AH, 24AH. and 200AH will be divided into 2 parallel 100AH, so 2 groups of 100AH cells, each group is 20, a total of 40 100AH batteries.