Marine Horizontal Self-priming Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 4000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Introduction
JSP/JSW series are suitable for pumping clean water. They are particularly suitable for domestic applications such as supply water from well, pool etc, the automatic distribution of water by surge tanks and pressure switch, gardening, and increasing of water pressure.
2.Features
a.JSP/JSW Series pump is constituted with clean water pump, non-return valve and air-water separation room, which located on the upside of the pump body.
b.During operating, it is no need to use foot valve, the only thing that you should do is just leave some water in the pump body.
c.After a few minutes' running, the water will be sucked out relying on the pump body itself.
d.They are particularly suitable for domestic applications such as supplying water from well, pool etc.
e. It is also suitable for water pressure boosting, gardening and automatic water supplying if combined with other appliances.
3. Construction
Pump Body: Cast Iron/Stainless Steel/Brass Front Cover: Cast Iron/Cast Iron with brass insert / Aluminum / Brass Impeller: Brass/Aluminum/PPO Mechanical Seal: Carbon/Ceramic/Stainless Steel Motor Housing: Alloy Aluminum Shaft: Carbon Steel/Stainless Steel/High Frequency Wedding Shaft Insulation: Class B / Class F Protection: IP44 / IP54 Cooling: External Ventilation
With thermal overload protector in single phase motor
4. Working Conditions
Max Temperature of Fluid to +80C
Max Pressure 10bar
Max Ambient Tenperature up to 40C
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
- Q: How to select metering pump head?
- When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
- Q: Is the vacuum pump air compressor?
- A vacuum pump is a device or device that uses a mechanical, physical, chemical, or physical chemical method to pump a vacuum from a container to be evacuated. Generally speaking, a vacuum pump is a device that uses various methods to improve, produce, and maintain a vacuum in a confined space.
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
- Q: Common failure treatment of piston pump
- Table 15 common troubles and treatment of hydraulic pumpsFault phenomenon, x09 cause analysis, x09 elimination method(1) the pump does not carry oil; the x091. pump does not turn x09 (1); the motor shaft does not rotate1) missed connection power supply2) electrical wiring and component failure, x09 check electrical and troubleshootx09x09 (2) motor heating trip
- Q: What are the differences between the sewage pump and the clean water pump?
- The main difference between the sewage pump and the clean water pump is that:Impeller and runner design, as well as other parts of the configuration are very different.1., in order to prevent clogging of sewage pump, the main design of large flow channel, so naturally lead to relatively low efficiency, so the head is generally not high. Clear water pump flow smaller, smaller clearance, the head is relatively high.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.
- Q: How to maintain and repair the booster pump of pipeline pump?
- 4. install "0" ring, tighten the pump body and motor end cover with bolts. Notice that the clearance between the front cover of the impeller and the pump body is 20. 0.5 mm. The impeller inlet, the outer ring and the pump body ensure a certain running clearance.5. the disassembly order is the opposite.
- Q: What are the characteristics of the piston pump?
- main features 1 、 double plunger structure, small pressure pulsation, long life of gem ball.2 、 imported precious stones and precious stones to ensure accurate flow.3, through the RS232 interface and computer communication, can be directly controlled by the computer.
Send your message to us
Marine Horizontal Self-priming Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 4000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords