HMR 16 Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 1000000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
series:
1,LED WIRE :diameter is 1.22mm to complete the seven stocks tinned copper wire , rated voltage is 330v . rated temperature is 105 . soft . white . UL certification line . the diameter of each stock tined copper wire is 0.127 mm . breakdown coltage is 2000v
2, SIZE: diameter--20mm height----45mm
3, INTERGRATED TEST : use a variety of materials mixed high voltage lamp power as onding filler material , suitaable for the high and low acess adapt to different environment . the surface of delicate , high hardness , excellent fire resistant , power loss and waterproff temperature pressure chemial resistance and other different problems
4, QUALITY ASSURANCE : environmental protection in line with ROHS directive requirements to provide ROHS test report
we producce the MR16-LED lighting empty cup of the same aesthetic that are not rough , excellent quality , high output , low pries , fast speed of production , prompt delivery , is an ideal choice to further the installation of the led board .
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Because some transformers are connected to 380V and 0, they can be 1000VA capacity, but because of the same line diameter, the 220V terminals and 0 can not provide the capacity of 1000VA.
- Q: The difference between lighting transformers and control transformers
- In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage
- Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
- See whether the lamp power saving, can not see whether it has a transformer, but to see the light efficiency of the lamp, that is, the ratio of light flux to power!Popular speaking, that is, spend the same electricity to see who sends more light!So, when comparing, ask what the light is, then judge again!The luminous efficiency unit is LM/W
- Q: What's the function of the lighting transformer?
- Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
- Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- In view of the power [kVA] conversion of each load, multiplied by the amount of consumption, according to the importance of the load, equipment location, voltage statistics, set the load line and load place of plastic case transformer capacity and its connection position. The future load power equipment shall be judged on the basis of prior installation or consideration of the economy in terms of equipment addition, installation, etc..
1. Manufacturer Overview
Location | Jiangsu,China (Mainland) |
Year Established | 2001 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe |
Company Certifications | ISO 9001:2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai,Ningbo,Lianyungang |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered |
Product Price Range | Low and/or Average |
Send your message to us
HMR 16 Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 1000000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords