ISG Vertical Centrifugal Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
ISG series vertical pipeline cooling water centrifugal pump
Performance Parameters :
a) Caliber: DN40-DN125mm
b) Flow: 2.8-100m3/hr
c) Head:3-38 m
d) Rotate speed: 1400,1450r/min
e) Viscosity: ≤100mm2/s
g) Motor power:0.12-30 KW
h) Working temperature: ≤100°C
ISG series single stage single suction pipeline centrifugal pump is designed on the base of
domestic execellent water power model and the performance parameter of IS series cen-
trifugal pump.
ISG Series centrifugal pumps are designed for such as hot water pump and corrosion resi-
stance pump and oil pump for the different temperatures and liquids. The pump has good
performance of reliable operation and high effeciency and little noise etc.
1,Compact structure,horizontal structure ,beautiful appearance and less area of occupied land,
which comparing with the ordinary ones is reduced by 30%;
2,Stable running ,low noise,high concentricity of assembly.By the straight joint between motor
and the pump.the moddle structure is made simplified ,thus enhancing the running stability ,
making the impeller of a good balance of moving -resting ,resulting in no vibration during run-
ning and improving the environment of usage .
3, No leakage .a mechanical seal of antisepticcaarbide alloy is ued for the shaft sealing so as to
let rid of the serious leakage of the fillings of centrifugal pumps and ensure the operating place
clean and neat ,
4,Convenient service .
1.ISG series vertical pipeline centrifugal pump is used to transport the water and other liquid
similar to the water in physical and chemical characteristic. It is widely used for the drainage
in industry and city, booster and water supply for high-building, irrigation in garden, booster
in fire fighting, transporting from along distance, water circulation in circultion system etc.
Working Temperature<80oC.
2. IRG series vertical hot water pump is suitable in metallurgy, chemical industry, textile, timber
processing, paper making and booster and circulating for high temperature and hot water in
hotel.
Working temperature <240C.
3. IHG series vertical pipeline chemical pump transports the liquid which is corrosive an without
solidgrain and similar to water in viscosity. It is suitable in petroleum, chemical industry,metal-
lurgy, electric power, paper making, food an pharmacy and synthetic fibre etc.
4. IHG series stainless steel chemicalcentrifugal pump with explosion-proof is suitable to trans-
port the flammable chemical liquid.
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- (1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
- Q: What should I pay attention to when buying a pump?
- Two, the first choice of large and medium-sized professional manufacturers, and through the quality identification of relevant departments, the market credibility of the better models, but also to the professional quality inspection institutions consultation.Three, check the motor grounding device for electric pump, water pump and motor axis, the motor should be in a proper position is provided with a grounding screw, and the grounding screw are arranged near the ground; grounding device of small submersible pump should be reliable and grounding wire, grounding wire cables should have the obvious grounding mark the flag should be in use; the motor is not easy to be worn during the period. This is one of the important safety indexes of electric pumps.
- Q: Concrete pump 125 pipe wall thickness
- Currently mainly divided into gate valve, concrete pump and S valve concrete pump. Another is a pump consisting of a pump body mounted on an automobile chassis and fitted with retractable or bent cloth poles
- Q: Difference between pump and compressor
- In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.The working principle of the linear pump is different from that of any other pump. It adopts the principle of magnetic suspension and the hydraulic structure of the spiral ring to realize liquid propulsion, that is, to cancel the shaft, to cancel the shaft connection, and to cancel the sealing structure of the shaft. After starting, the electric current is transformed into a magnetic field, and the magnetic field force drives the spiral ring to move, namely, the spiral ring promotes the liquid advance.Compressor (compressor), a driven fluid machine that promotes low-pressure gas as a high pressure gas, is the heart of a refrigeration system. It is of low temperature and low pressure refrigerant gas suction pipe from the suction, through the operation of the motor drives the piston to compress it after high temperature and high pressure refrigerant gas discharge pipe to the exhaust, to provide power for the refrigeration cycle, so as to realize the compression and condensation (exothermic), expansion and evaporation (endothermic) refrigeration cycle.
- Q: Is the sewage pump the same as the mud pump?
- Sewage pump is mainly used for industrial wastewater treatment, sewage treatment, environmental protection has played a big role. Among them, the sewage pump is also a sewage pump with cutting wheel, such sewage pump can be chopped dirt, and then extract the sewage clean.
- Q: Suction stroke and lift of water pump
- Lift pump lift pump can lift refers to the height, usually expressed in H, the unit is m. centrifugal pump lift to the impeller center line, divided by two parts. The vertical height from the pump impeller centerline to the water surface, the water pump to suck water up to the height, called water head, referred to as suction pump impeller; from the center line to the vertical height of the water tank, the water pump can put pressure on the height, called water pressure head, referred to as the pressure. The pump head = + suction head pressure water head should be pointed out that the nameplate marked head refers to the pump itself can produce lift, it is not with the pipe flow friction resistance caused by the loss of lift. In the selection of water pump, attention can not be ignored. Otherwise, will be pumping Sheung Shui.
- Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
- The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
- Q: Significance of water pump model ISO50-160
- Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.
- Q: What's the submersible pump?What is a submersible pump, and what about it?
- Not afraid of water, because it is placed in the water itself to cool themselves, you can use for a long time. The amount of water pumped and the height of the water now basically meets the needs of a small amount of individual and a large number of factories. This is the submersible pump, the water pump in the water. You can see.
- Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
- This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Send your message to us
ISG Vertical Centrifugal Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords