Specifications

1,Single-stage single-suction 
2,Axial suction centrifugal pump 
3,Back-pull-out design

Min inlet pressure

Min inlet pressure depends on NPSH +0.5m safety margin + gasified pressure. It should be re-calculated the inlet pressure if one of the following happens.

*The liquid is more warm.

*The flow exceeds the nominate value.

*Suction distnace is very long or inlet pipe is very long.

*System pressure is too little.

*Inlet pressure is low.

 

Typical application

*Clean, thin, non-corrosive, non-flammable or non-explosive liquid without grain or fiber.

*Water supply system

*Heat, air condition system

*Irrigating, farming

*Booster, constant pressure water supply

*Industry cooling, heater circulation system

*Firefighting, splitting system

*Industry transferring, drainage system

 

Construction

*Non-self-priming, single stage, single suction, horizontal, axial suction and radical discharge, pump body is fixed by base.

*Use bering cradle, which can orientate bearing, prevent from radical vibration, improve the rigidity of rotary part.

*Compacted shaft, use deep grove grease lubricated roller bearing.

*Connect pump and motro with semi-flexible coupling.

*Use standard wearable mechanical seal.

*TEFC motor, size complies to IEC standard, installation type B3.

*The dimensions is conform to ISO 2858

 

Specificaton

*Flow: Max 520m3/h

*Power:Max 160Kw

*Head: Max 160m

*Liquid temperature: -15°C - 110°C

*Working pressure: Max 16bar

*Inlet and Outlet diameter: Inlet diameter: DN50-DN200; Outlet diameter: DN32-DN150

 

Curve conditions

*Curves tolerance is according to ISO9906, Annex A;

*All curves are based on the measured value of constant motor speed 2900rpm, 2950rpm, 1450rpm or 1480rpm.

*The measurements were made with airless water at temperature of 20°C. The curves apply to a kinematic vis-cosity of 1 mm2/s (1 cst)

 

Features

*Back-pull-out design, without having to disurb pump body and pipelines when servicing.

*All the models only use 4 kinds of pump shafts and bearing cover, make parts exchangeable.

*Impeller is optimum design, inlet is enlarged, no whirlpool, deduct the water pump NPSH efficiently, which makes pump work stable with little noise.

*Casing and casing cover use wearing neck ring structure, which makes pump easy to maintain, makes parts work longer. The replaceable seal ring, makes pump work efficiently in a long time.


Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q: What is a gear pump for?
Internal wear of oil pumpOil pump parts wear will cause leakage. The large leakage area between the floating axle sleeve and the end face of the gear is the main part of the inner leakage. This part of the leakage accounted for about 50%~70% of the total leakage. The pump efficiency of the gear pump is much lower than the input power when the gear pump is worn and leaked. All of its losses are converted to heat energy, which will lead to overheating of the oil pump. If the joint plane is pressed, the movement of the floating axle sleeve will cause a little wear and tear when the work is in use, so that the farm tools can be lifted slowly or can not be improved, so the floating axle sleeves must be replaced or repaired.
Q: How many kinds of pumps are available and the operating principles of various pumps?
The volume type pump, depending on the periodic change of sealing liquid containing space volume, the energy is periodically transmitted to the liquid, the liquid pressure increased to force the liquid discharge, according to the motion form of work elements can be divided into reciprocating pump and rotary pump. Other types of pumps transmit energy in other forms. As the jet pump work on high-speed jet of fluid will be required to transport fluid suction pump after mixing for momentum exchange in order to transfer energy; water hammer pump by water when braking in the flow of energy transfer is to rise to a certain height; the electromagnetic pump is energized to make the liquid metal in the electromagnetic forces generated in the flow and transport. In addition, the pump can also be classified according to the nature of the transmission fluid, driving methods, structure, use and so on.
Q: What kind of motor does the hydraulic pump need?
Calculation of actual oil pump power:First count the flow: Q=dn L / minD displacement / revN RPM / minThen calculate the actual power: N=QP/ (60K) kwQ flow L / minP MPa MPaK total efficiency (usually 0.85)I do not know what the landlord said, 2.5L is the displacement or flow at the end, the concept must not be confused
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The operating pressure of the hydraulic system depends mainly on the load. Generally speaking, the working pressure of the hydraulic system means the highest working pressure of the system. If the pressure is higher than the value of the equipment, the relief valve works to relieve pressure. The actual working pressure of the hydraulic system is determined by the load, which refers to the actual pressure of the hydraulic oil and can be read directly from the pressure gauge. The pressure increases with the increase of the load. You Li's balance can know: the thrust of the cylinder = the load, the thrust of the cylinder = the working pressure of the hydraulic oil, the working area of the cylinder, the working pressure = the load / the area of the cylinder.
Q: Is vane pump good or gear pump good?
1) the reversible design of gear pumps can also usually reverse, but reverse after the suction port change, and the pump safety valve does not work; leaf pump is generally not allowed to reverse. 3) the single acting vane pump can be designed to change the eccentric distance by moving the stator at the constant speed, so as to achieve the purpose of variable direction.
Q: What are the problems that should be paid attention to when using vacuum pumps?
What are the problems that should be paid attention to when using vacuum pumps?
Q: What are the differences between the sewage pump and the clean water pump?
The main difference between the sewage pump and the clean water pump is that:Impeller and runner design, as well as other parts of the configuration are very different.1., in order to prevent clogging of sewage pump, the main design of large flow channel, so naturally lead to relatively low efficiency, so the head is generally not high. Clear water pump flow smaller, smaller clearance, the head is relatively high.
Q: What is the difference between centrifugal pump and self suction pump? Which is better?
In order to prevent the filling liquid into the pump shell because of gravity flow in the low groove, in the pump suction pipe at the entrance of a non-return valve (valve); if the location of the pump below the liquid level in the tank, then start without irrigation pump.Self-priming pump is a self-priming centrifugal pump, centrifugal pump is a kind of.Specific choice of a pump, depending on your specific parameters and conditions of use.