Specifications
1,Single-stage single-suction
2,Axial suction centrifugal pump
3,Back-pull-out design
Min inlet pressure
Min inlet pressure depends on NPSH +0.5m safety margin + gasified pressure. It should be re-calculated the inlet pressure if one of the following happens.
*The liquid is more warm.
*The flow exceeds the nominate value.
*Suction distnace is very long or inlet pipe is very long.
*System pressure is too little.
*Inlet pressure is low.
Typical application
*Clean, thin, non-corrosive, non-flammable or non-explosive liquid without grain or fiber.
*Water supply system
*Heat, air condition system
*Irrigating, farming
*Booster, constant pressure water supply
*Industry cooling, heater circulation system
*Firefighting, splitting system
*Industry transferring, drainage system
Construction
*Non-self-priming, single stage, single suction, horizontal, axial suction and radical discharge, pump body is fixed by base.
*Use bering cradle, which can orientate bearing, prevent from radical vibration, improve the rigidity of rotary part.
*Compacted shaft, use deep grove grease lubricated roller bearing.
*Connect pump and motro with semi-flexible coupling.
*Use standard wearable mechanical seal.
*TEFC motor, size complies to IEC standard, installation type B3.
*The dimensions is conform to ISO 2858
Specificaton
*Flow: Max 520m3/h
*Power:Max 160Kw
*Head: Max 160m
*Liquid temperature: -15°C - 110°C
*Working pressure: Max 16bar
*Inlet and Outlet diameter: Inlet diameter: DN50-DN200; Outlet diameter: DN32-DN150
Curve conditions
*Curves tolerance is according to ISO9906, Annex A;
*All curves are based on the measured value of constant motor speed 2900rpm, 2950rpm, 1450rpm or 1480rpm.
*The measurements were made with airless water at temperature of 20°C. The curves apply to a kinematic vis-cosity of 1 mm2/s (1 cst)
Features
*Back-pull-out design, without having to disurb pump body and pipelines when servicing.
*All the models only use 4 kinds of pump shafts and bearing cover, make parts exchangeable.
*Impeller is optimum design, inlet is enlarged, no whirlpool, deduct the water pump NPSH efficiently, which makes pump work stable with little noise.
*Casing and casing cover use wearing neck ring structure, which makes pump easy to maintain, makes parts work longer. The replaceable seal ring, makes pump work efficiently in a long time.
- Q: What are the uses and precautions of magnetic pumps?
- 2, when the suction surface above the pump axis, before starting the valve can open the suction pipe, if the aspiration level below the pump axis, the pipeline to be equipped with bottom valve;3, the pump should be checked before use, the motor blade rotation to be flexible, no jam, no abnormal sound, the fasteners should be tightened;4 、 check whether the motor rotation direction is consistent with the magnetic pump steering mark;
- Q: What is a solution pump?
- Principle and structure features of canned motor pumpThe ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and drive the rotor. This structure eliminated the traditional centrifugal pump with a rotary shaft sealing device, it can do no leakage.The pump and motor pump together, motor rotor and pump impeller fixed on the same shaft, use of shielding the rotor and the stator of the motor rotor separated in the medium, its power is transferred to the rotor through the stator magnetic field.
- Q: What is the minimum continuous flow of a pump?
- At'-- the allowable temperature rise of pumping medium,C- pumping medium specific heat, kj/ (kg DEG C);Ho- off dead center lift, M.Minimum continuous flow minimum continuous stable flow and minimum continuous thermal flow and the maximum value in the selection, or use the pump process, the minimum continuous flow process requirements must be greater than the minimum flow rate of the pump, otherwise it will cause the pump cavitation, vibration and noise, so that the pump parts damaged. If the minimum continuous flow the pump can not meet the minimum requirement's process, can install the bypass reflux device or reflux system in the pump pipeline, to ensure that the minimum continuous flow pump.
- Q: How to select metering pump head?
- The manufacturers of chemicals will give relevant recommendations, or consult the ProMinent chemical corrosion chart to determine the compatibility of the chemicals with the contact material.
- Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
- These two don't mean the same thing? That is, the pump outlet can be changed
- Q: How is the pump level of submersible sewage pump determined?
- Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
- Q: How high can the pneumatic diaphragm pump be?
- Diaphragm capacity, high temperature, pneumatic diaphragm pump ability, high temperatureMany users do not know how high the temperature resistant diaphragm pump, diaphragm pump either electric diaphragm pump or pneumatic diaphragm pump products it cannot do without diaphragm attachments, diaphragm materials mainly fluorine rubber, rubber, rubber, polyether road three EPDM, PTFE several, if not considering the gas temperature resistant diaphragm made of stainless steel. The temperature to 600 degrees of diaphragm pump diaphragm pump, but must use the diaphragm, so the diaphragm pump can Naiduo high temperature depends entirely on the diaphragm was affected by temperature, following to share various diaphragm pump diaphragm material and different material temperature choice diaphragm pump product right:
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.
- Q: What is a feed pump?
- Because under normal circumstances, the water pump suction port flow rate is low, can not meet the requirements of high pressure water injection pump. Therefore, the purpose of adding a feeding pump at the front of the water injection pump is to increase the flow rate of the inlet of the high-pressure water injection pump so as to meet its water supply requirements!
- Q: What is the distance between the pump and the wall?
- Mainly depends on the maintenance, installation is convenient, but there is no other requirements.