High Medium Voltage Drive 6.6KV 1000KW RMVC4000-A066/1250 VFD
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Energy-saving Solutions for Enterprise
1、Program Overview
◆Saving energy achieves 10% -70%
◆The enterprises do not need to pay for expense of equipment manufacture and installation.
◆Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
◆According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)。
◆Our company will no longer charge the saving electricity expense after recovering the investment.
The significance of the program:
1)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility。
2)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.
2、Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment
3、Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.
- Q: Is the laptop power adapter high temperature normal? Is there anything else?
- Hello, the power adapter because there are a lot of electronic components so hot is normal, the general hand feels hot does not feel hot on it, if hot, then there is a problem.
- Q: In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
- If there is no load, the demolition of the gearbox is the same can be run.
- Q: What parts of the inverter composition
- Simply put, the inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
- Q: Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
- n the motor pole, an Antarctic (S pole), an Arctic (N pole), calculate a pair of poles, the number of pole pairs is how many such "pairs" (S pole + N pole). 2 pole motor --- pole pairs 1 = P = 1,4 pole motor --- pole pairs 2 = P = 2, and so on.
- Q: Laptop computer about electricity no electricity, is the power adapter problem?
- This situation is definitely not about what power off, if it is really about electricity no electricity, then your laptop is a one-time shutdown, rather than the screen flashing. I think this situation is more like a laptop screen lamp problem. Is unlikely to be a power problem. The screen flashes from the surface that there may be enough current. If the adapter can not provide enough current for the notebook, then the notebook will be over-current protection, which automatically shut down. You can find an adapter with the same output voltage as your adapter, the output power is greater than or equal to your adapter other adapter, if the situation remains the same, then it is certainly the problem of the lamp. But the inferred will not be a power problem.
- Q: What is the single axis of the inverter and multi-axis applications
- The frequency changer mainly consists of rectification (alternating current direct current), filter, re-rectification (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
- Q: 6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
- To 400HZ, so high frequency you tried it? I only tried 80HZ, if you tried, please tell me some of the high frequency of the actual situation will produce some changes in the motor,
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- Not a drive failure! Is an external signal problem.
- Q: Speed of 3000 r / min three-phase motor how to change its speed
- The key lies in two points: 1, you ask the variable range is how much? 2, your motor had a few qualifying? If your motor is 6 outlet, and you only need to speed, plus your motor is also an asynchronous motor, and you do not have the requirements of the load; then congratulations, you can achieve "speed" You just put the motor wiring way to do a △ - Y or Y - △ conversion can be achieved. If the above conditions you have one or two can not meet, then your best way is to buy a drive to achieve the variable speed. Of course, you can also make some changes to the winding to achieve the so-called single-winding multi-speed operation (this change, but the need for a certain technical content).
Send your message to us
High Medium Voltage Drive 6.6KV 1000KW RMVC4000-A066/1250 VFD
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords