• High Medium Voltage Drive 4.16KV 3000KW VFD System 1
High Medium Voltage Drive 4.16KV 3000KW VFD

High Medium Voltage Drive 4.16KV 3000KW VFD

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
10000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Energy-saving Solutions for Enterprise
1、Program Overview
◆Saving energy achieves 10% -70%
◆The enterprises do not need to pay for expense of equipment manufacture and installation.
◆Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
◆According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)。
◆Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility。
2)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2、Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3、Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Q:Do you need to rectify before switching?
I used to do the frequency of the words to be rectified
Q:What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
The soft starter is activated by adjusting the voltage and current, and the frequency converter starts the motor by changing the frequency of the power supply. The soft starter can theoretically smooth and gradually start the motor to the maximum speed. No impact current (ordinary start-up current is 6-7 times the rated current) The inverter is best suited for tap water and fans, etc. The soft starter is not suitable for everything except for heavy load start.
Q:Why G120 inverter to be equipped with 4-pole motor?
I add point with the premise of the inverter is to understand the mechanical load characteristics (or process, etc.), can the parameters set.
Q:Will the laptop's power adapter is not the original good?
As long as the power and current are equal or slightly larger than the original adapter, but the voltage must be equal to the original adapter on the line.
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q:What is the number of parameters of the motor frequency of the Siemens inverter?
Different types of Siemens frequency changer pole pair parameters different. 6SE70 is p109; The following is the p109 parameter description: P109 * Motor #PolePairs 109 For the synchronous / asynchronous motor input motor pole pairs of the function parameters. If the rated frequency (P107) and rated speed (P108) change, automatic calculation This parameter, if necessary, checks and verifies this parameter. note: - for some of the pulsed encoders (P130 = 11, 12, 15, 16) The maximum number of pole pairs of P109 = 15 can be achieved - P109 must be written when the write function (P060 = 6) is implemented. - Automatic calculation of the pole pair on the motor with regenerative feedback on the rated data Number to be added. Where the function map: 360.2, 361.2, 362.2, 363.2, 364.2 ? MM4 series is r313, which is calculated by the input rated frequency and rated speed calculated read-only value, must be selected in the p3900 to calculate the correct value. You can also set pole pairs by p314. ? S120; G110; G120; G130; G150; S150 with MM4 series.
Q:Why the notebook power adapter can not be universal
Third, the current is different Different brands of laptop power adapter current is not the same, for example: under normal circumstances IBM is 4.5A, Dell is 3.34A, Hp is 2.7A, Sony is 4.1A and so on. In fact, the same brand of laptop power adapter voltage and current are not the same. So, even if the same brand of notebook computers channeling with power adapter to confirm the voltage and current specifications.
Q:Is the number of Amps of the notebook power adapter higher than the original number of security on the computer?
Sure answer, no! Rest assured with it, but be careful not to buy the cottage goods, this on the computer and security is not good. good luck!
Q:Laptop power adapter in the ring is how is it?
Notebook power adapter generally use the switch circuit, the output 12V DC power supply, as the notebook DC / DC converter circuit power supply; In the switch circuit, the most prone to "creak" sound is the switch transformer coil (ringing), or high-voltage filter capacitor (fire);
Q:18: 5 kilowatts bipolar multi-pole pump motor with inverter
Under normal circumstances, with 15KW inverter on it.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords