• High Medium Voltage Drive 4.16KV 1500KW VFD System 1
High Medium Voltage Drive 4.16KV 1500KW VFD

High Medium Voltage Drive 4.16KV 1500KW VFD

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
10000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Energy-saving Solutions for Enterprise
1、Program Overview
◆Saving energy achieves 10% -70%
◆The enterprises do not need to pay for expense of equipment manufacture and installation.
◆Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
◆According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)。
◆Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility。
2)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2、Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3、Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Q: The parameters of the inverter is 4, 6 motor can be used
The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on. The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.
Q: What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
Electronic governor is the use of control thyristor conduction angle to change the motor supply voltage, the motor characteristics of the curve down to change the speed of asynchronous motor. Its characteristics are as follows: the motor speed adjustment range is small, low speed when the motor load capacity is poor, the speed decreases, the motor torque decreases, not applicable with constant load, when the speed is low, prone to stall phenomenon; Applicable to fan load. Inverter speed is to change the frequency of the motor to achieve the AC asynchronous motor speed adjustment, speed adjustment balance, the motor load characteristics do not change with the speed change, suitable for load adjustment and constant torque adjustment. Excellent performance, but the cost is higher.
Q: How do I protect the inverter when the three-phase two-pole motor is running?
A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
Q: Inverter signal line analog 4-20mA connection positive and negative can be reversed?
Theoretically reverse seems to be possible, but the operation will be normal, you can do experiments to try what is the result. Various manufacturers of the inverter may be the treatment of this problem will be different.
Q: How is the notebook with a power adapter?
The safest option is to choose the same type of notebook power adapter. When in some cases (the original adapter is too expensive or not available), you can select the operating parameters and output connectors and the original adapter.
Q: Fuji inverter motor set the number of poles will not have any effect?
The number of motor poles corresponds to the speed of the motor, the number of poles is not set when the speed of the control error, in the high speed requirements of the transmission is not allowed.
Q: Who knows how the inverter is calculated?
Quadrupole motor synchronous speed is: 1500 r / min, but the actual motor speed will be more than 14 turn.
Q: The motor is 2 pole with the inverter frequency to 50hz why the speed is only 1500 rpm
Hello, poles (a pair of pole) motor, the theoretical speed of 50 rpm when the theoretical speed of 3000 r / min, if the display shows only 1500 rpm, it is possible to have a motor shaft speed or speed device Yeah, gear ratio of 2 to 1 ,
Q: The inverter flat rate transferred to 29, on the submersible pump to burn the coil ?!
1. submersible pumps are generally the problem, far away from the reflection voltage, the pump insulation breakdown, in particular, to better pump. 2. Distance away, the inverter and pump connection thicker. 3. Then on the output filter.
Q: B2b frequency how to speed
can be seen from the formula: frequency f changes, the speed will follow the change. 2) When the motor connected to the public grid, you can use the inverter (2) When the motor is connected to a single motor, you can change the output frequency of the generator directly to change the output frequency of the generator. Change the frequency of the power supply to the motor to change the speed of the motor.

Send your message to us