• High-end Horizontal Biomass Boiler--116KW System 1
  • High-end Horizontal Biomass Boiler--116KW System 2
High-end Horizontal Biomass Boiler--116KW

High-end Horizontal Biomass Boiler--116KW

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
-
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

High-end Horizontal Biomass Boiler--116KW


This boiler is 116KW one.


 

Introduction:

The first horizontal biomass boiler in China

High-end product---Longxiao series A, B, C


Technical features:

By the great effort, we have developed the first biomass boiler without grate. There are three kinds of hot water boilers as following:

A: blue touchscreen control system, burning any biomass fuel without dark smoke.

B: colorful touchscreen control system. motor frequency control system. drain the coked fuel in the combustion procession. burning all coked biomass fuel.

C: large colorful touchscreen control system. intelligent control system, internet control system. drain the coked fuel in the combustion. burning all coked biomass fuel.

 

Characteristics:

1. Different from tradition vertical boiler, any parts of boiler could be checked and repaired. Even the fire pipes in the boiler could be replaced without boiler disassembled.

2. It adopts world leading patent combustion system. Boilers without grate will need no more grate transporting to solve coked fuel burning problem.

3. High temperature in the hearth could be controlled to make sure that temperature is enough high to do biomass pyrolysis gasification and complete combustion. With specially designed airflow spraying, tar will not be attached to the hearth after long-time combustion and pipes will not be blocked by the attached tar, it will do little effect on the boiler's efficiency after long time using, this is what users will neglect. Long-time energy saving is what matters.

4. As store is directly connected to the hearth, many biomass boilers catch fire easily. Applying anti-back fire structure and back-flow prevention device, so that only biomass fuel can be put  into hearth, high temperature airflow can't flow into bunker. We are equipped with safety fire protection device, even when the back-flow  prevention device fails, automatic monitoring feeding system will start to force high temperature into hearth. Boiler will stop working only after cleaning all the fuels.

5. Change the traditional boiler feeding way, decrease the feeding height of bunker, increase the capacity, reduce the labor strength.

6. Traditional biomass boiler only monitor output water temperature, Longxiao series adopts touchscreen control system, clients can monitor the parameters of temperature of input water, output water, smoke, fuels in bunker, combustion in hearth etc. After the change of relevant data, it will timely remind the user of maintenance, so that to allow user to get more information about running status and energy-saving data.

 

 

Product specification:  covers from 10*104Kcal~180*104Kcal this list shows parts of specifications for reference)  

 

Item

Unit

CLHS0.12

CHLS0.24

CLHS0.35

CHLS0.48

CLHS0.60

CLHS0.73

Rated head

Kcal

10*104

20*104

30*104

40*104

50*104

60*104

Rated discharge pressure

Mpa

0Normal pressu re

Rated temperature of outlet water

                                         85

Rated temperature of return water

60

Heat efficiency

%

90

Water inlet

MM

40

50

50

65

65

80

Water outlet

MM

40

50

50

65

65

80

Drain hole

MM

40

50

50

65

65

80

Vent hole

MM

40

50

50

65

65

80

electricity

KW

1.1

1.5

1.8

2.2

2.7

3.2

size

length

MM

2060

2360

2560

2790

2820

3200

width

MM

650

738

850

1010

1060

1150

height

MM

1760

1760

1760

1960

1960

1960

High-end Horizontal Biomass Boiler--116KW




 

Q: In pr, what is a boiler plate?
I don't know what you mean by pr, but boiler plate usually refers to standard language that appears in documents (e.g., a lease of an apartment) of certain types.
Q: I want to build a powerplant system with rate capacity 7 MW.
In most countries you have to be licensed to do this, as there are many ways to have a disaster, ie, an exploding boiler with loss of life. And you are obviously not qualified. So hire a professional to do this. .
Q: I think it implies a shady business that is only around for a short time. This phrase isn't used so much anymore, but I was wondering what it was all about.
A business run out of the basement (boiler room)...kind of shady. Often involves calling thousands of people on the phone and selling something fishy, like stock in a company, where the company isn't real or isn't successful.
Q: My baseboard heating was starting to sound like a babbleing brook. So i drained the pipes and I refilled them. I am thinking i didnt refill them enough because it STILL sounds like a babbleing brook.There are 2 guages on the side of my boiler. How do I know what preassure to make the pipes?I have 2 zones. There is also a weird bell shaped switch or lever that comes immidiatly after the water pipe that feeds the boiler. What is it for?
Not sure what type of boiler you have but you could try to use a auto-vent.These will screw into the elbow next to your baseboard.The bell shaped devise should be your backflow preventer.You should not have to touch that.
Q: Boiler check first or external inspection first
In the boiler with a general annual inspection, every two years to conduct an internal inspection, every six years to conduct a hydraulic test.
Q: I asked earlier about replacing my cylinder, now im wondering as this needs to be done, would it be better at this time if i could afford it, to actually change my whole system, as in a new boiler which does not need a water tank.My current boiler is a Potterton Netaheat 50e. What is the going rate for this work please? Thanks again in advance :)
you are thinking of a combi. dont get one, when it goes you have no heating or hotwater
Q: If a bath is filling upstairs, taps down stairs cannot be used at the same time?
Yes you are right. A combi is a one tap boiler, but you can put as many taps as you like on the circuit, but you will only get a full flow from one at a time. If somebody runs the bath, you have to wait before you fill the sink. But they are only suitable for small places and this is not really a problem, you just have to learn to live with it. The only real problem with them is if you are running a shower and somebody else turns a tap on downstairs, the shower stops running just as you are going to wash the soap from your eyes. No fun that. But all systems have this same problem to a greater or lesser degree. So go ahead and get a combi, as long as you understand they have limitations , they are very good.
Q: I have a burnham oil fired boiler. How do i lower the hot water temp.?
Burnham Furnace
Q: and then turned off. It wont turn back on. I filled up the tank again, but still nothing. my landlord said I let the heat ran out and that the heater needs to get primed. I have no clue what that means. How often does a boiler system need to be primed, what causes it to need priming
it wouldn't shut off at a 1/4 tank of fuel left gage must not be right and in reality you were on empty but to prime or bleed the fuel line , you have to go to the furnace and look at the burner on the side of it is your fuel line going to the pump , on top of the pump you will see a bleeder valve( you should have a container and small hose that can fit on top of the bleeder valve )because when you turn that nut it will open the valve and 1st you will get air then fuel after you get fuel close the nut . and the furnace should come on . you might have to reset the red button a few times on the burner because it will shut down about after a minute of pumping and not lighting. according how far away the fuel tank is . it could take 3 or 4 tries to get it primed .good luck
Q: What do I do if my viessmann vitodens boiler 100 is showing 0.5 bar ? help, have no hot water or heating now:(?
Increase the water pressure on the boiler. There is a fexible filling loop fitted with a valve at one end to open the filler. Open, and fill to 1 and a half bar, then turn the valve off. Boiler should then be okay. If you start to lose water pressure often, then you have a faulty pressure valve and it has to be replaced. They cannot be repaired.

Send your message to us