The detailed content
FST - 610 high-power series high-performance non-inductive vector frequency converter
(7.5 kw to 630 kw, 3 phase, 380 v)
Software features:
G/P and wide scope of application.
A variety of control mode: V/F control, non-inductive vector control and torque control.
High start torque: 180%, 0.5 Hz.
Multistage speed, simple PLC and PID control.
Programmable input/output terminals.
Instantaneous power lost, don't stop function.
Multiple frequency setting methods.
Speed tracking restart function.
Automatic output voltage adjustment function.
Frequency hopping control function.
Volatile inhibition function.
A variety of fault protection function.
Structure features:
Layout optimization of components, small volume, light weight, easy to transport, installation and maintenance.
Good heat dissipation design, low temperature, stable performance.
- Q: In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
- If there is no load, the demolition of the gearbox is the same can be run.
- Q: How can a variable speed multi - speed three - phase asynchronous motor be controlled by a frequency converter?
- With the inverter control, then you do not need multi-speed motor, because the inverter can directly control the motor speed, if the two together, the formation of a waste.
- Q: 2 pole 0.75 kW motor can increase the speed through the inverter?
- 2-pole motor speed of about 2900 r / min or so, 4-pole motor speed of about 1400 r / min or so, which are in the case of 50HZ,
- Q: Pump frequency converter instantaneous restart and restart the problem
- Speed tracking start. The specific to ask you to drive the inverter that guy. He earned your money there is a need for technical support
- Q: 5.5 kW 4-pole motor with the fastest speed can exceed the rated speed?
- Can not be exceeded Although the inverter can run out of the motor rated speed as the motor will soon burn You want your running speed of 2m / s you have to run 5m / s so go eggs do not pull the
- Q: Delta VFD-F frequency converter how to adjust the number of poles
- Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- This is not a fault! Only after the inverter receives the base block signal, it is not output!
- Q: Speed of 3000 r / min three-phase motor how to change its speed
- The key lies in two points: 1, you ask the variable range is how much? 2, your motor had a few qualifying? If your motor is 6 outlet, and you only need to speed, plus your motor is also an asynchronous motor, and you do not have the requirements of the load; then congratulations, you can achieve "speed" You just put the motor wiring way to do a △ - Y or Y - △ conversion can be achieved. If the above conditions you have one or two can not meet, then your best way is to buy a drive to achieve the variable speed. Of course, you can also make some changes to the winding to achieve the so-called single-winding multi-speed operation (this change, but the need for a certain technical content).
- Q: The laptop's power adapter is too hot to do
- Installed adapter heat should be no problem, I am now under the books, the fan mouth is very hot, the weather may be more and more hot it
- Q: Why G120 inverter to be equipped with 4-pole motor?
- I add point with the premise of the inverter is to understand the mechanical load characteristics (or process, etc.), can the parameters set.