Frost frequency converter good delivery time and price
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
The detailed content
FST - 610 high-power series high-performance non-inductive vector frequency converter
(7.5 kw to 630 kw, 3 phase, 380 v)
Software features:
G/P and wide scope of application.
A variety of control mode: V/F control, non-inductive vector control and torque control.
High start torque: 180%, 0.5 Hz.
Multistage speed, simple PLC and PID control.
Programmable input/output terminals.
Instantaneous power lost, don't stop function.
Multiple frequency setting methods.
Speed tracking restart function.
Automatic output voltage adjustment function.
Frequency hopping control function.
Volatile inhibition function.
A variety of fault protection function.
Structure features:
Layout optimization of components, small volume, light weight, easy to transport, installation and maintenance.
Good heat dissipation design, low temperature, stable performance
- Q: Laptop warranty period is not over, the power adapter is broken, repair money?
- Do not money, first to see where the dealer, if there is no answer, went directly to the repair station, with a good warranty card and other things, that reason you can! The
- Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- Soft starters and frequency converters are two completely different uses of the product. The frequency converter is used for the need for speed control where the output not only changes the voltage but also changes the frequency; the soft starter is actually a voltage regulator for the motor to start when the output only changes the voltage and does not change the frequency. The frequency converter has all the soft starter functions, but its price is much more expensive than the soft starter, the structure is much more complex. Soft starter (soft starter) is a set of motor soft start, soft stop, light load energy saving and a variety of protection functions in one of the new motor control device, known as the Soft Starter abroad. The softener uses a three-phase anti-parallel thyristor as a voltage regulator, which connects it between the power supply and the motor stator. This circuit, such as three-phase full-bridge rectifier circuit. When using the soft starter to start the motor, the output voltage of the thyristor gradually increases, the motor gradually accelerates until the thyristor is fully conductive, the motor works at the mechanical characteristics of the rated voltage, smooth start, reduce the starting current and avoid starting the overcurrent trip. When the motor reaches the rated speed, the start-up process ends, the soft starter automatically uses the bypass contactor to replace the completed thyristor, providing the rated voltage for the normal operation of the motor to reduce the heat loss of the thyristor and prolong the service life of the soft starter , To improve its efficiency, but also to avoid the harmonic pollution to the grid. Soft starter also provides soft stop function, soft stop and soft start the process of reverse, the voltage gradually reduced, the number of revolutions gradually reduced to zero, to avoid free-wheeling caused by the impact of torque. How the frequency converter works
- Q: A water supply project, how to choose electrodes and frequency converters, such as giving a 7-storey water supply
- 4. Set by pressure (0.3-0.4Mpa). Control the inverter can be.
- Q: The notebook power adapter flashes
- It seems you are still a novice ~ know the output voltage with the current is not ~ know the words to dig treasure shop name marked (days and along the power adapter) to find it ~ you have to ~ the price will not be expensive ~ I am in the days of business with the company Repair ~ ~
- Q: What is the frequency converter used to do, why some motor with the inverter?
- Therefore, the exchange frequency control has gradually replaced the traditional traditional slip speed, variable speed control, DC speed control system, more and more widely used in metallurgy, textile, printing and dyeing, smoke machine production lines and buildings, Water supply and other fields. The motor is equipped with the frequency converter.
- Q: What is the maximum speed adjustable for a 4-stage motor with a rated frequency of 50Hz / 60Hz?
- Motor speed and frequency of the formula N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (seconds); F - power frequency (Hirsch); P - pole pairs of motor rotating magnetic fields. China provides the standard power frequency f = 50 weeks / second, so the rotation of the magnetic field of the size of the theoretical diameter only with the magnetic pole. The number of pole pairs is large, and the rotational speed of the rotating magnetic field is low.
- Q: Speed of 3000 r / min three-phase motor how to change its speed
- Speed of 3000 r / min three-phase motor speed: Variable pole speed Change the motor stator winding wiring way to change the motor pole number, which can be level to change the synchronous speed, to achieve a variable speed motor speed. This type of speed motor currently has a series of products to choose from, such as single-winding multi-speed motor. Frequency Change the asynchronous motor stator terminal input power frequency, and make it continuously adjustable to change its synchronous speed, to achieve the motor speed control method known as frequency control. The most energy efficient is the frequency conversion motor, but the need to install the inverter in the power part of the cost is too high.
- Q: How do I select a drive? Which brand is better
- ??8, drive explosion-proof motor, the inverter is not explosion-proof structure, the inverter should be set in a dangerous place outside. ????9, the use of inverter drive gear motor, the use of the gear by the part of the lubrication part of the lubrication control. When lubricating oil is lubricated, there is no limit in the low speed range. If there is a high speed range above the rated speed, there is a risk that the lubricating oil may be used. Therefore, do not exceed the maximum speed allowable value. ????10, the inverter drive winding rotor asynchronous motor, most of the use of existing motor. Winding motor and ordinary squirrel-cage motor compared to the winding motor winding impedance is small. Therefore, it is prone to overcurrent trip due to ripple current, so a frequency converter larger than the normal capacity should be selected. General winding motor for flywheel torque more occasions, in the set acceleration and deceleration time should pay more attention.
- Q: Laptop power adapter is used to do what
- The laptop's power adapter is a device that converts 220V AC power from a power supply unit to a low-voltage direct current device for powering a laptop. Power adapter output low-voltage direct current into the computer, but also through the computer motherboard power circuit to further deal with, resulting in 1.8V, 3.3V, 5V and other sets of voltage for memory, CPU and other components to run; another power adapter to provide the power can also be related Charge control circuit to charge the battery for the laptop.
- Q: B2b frequency how to speed
- How does changing the power frequency to change the speed of the motor? When the motor is connected to the power supply to drive the normal operation of the load, at this time to change the power frequency, such as the current frequency down, the motor armature rotating magnetic field speed will decline, the rotor conductor cutting magnetic field speed decreases, turn from the induced potential , The rotor current decreases, the torque decreases, the load on the shaft does not change, the torque will be less than the load resistance torque, the motor rotor speed decreases, the rotor conductor cutting the magnetic field line speed increases, the rotor induced potential increases, the rotor current increases, The torque rises until it is equal to the load resistance torque, and the speed is smaller than the original. After stabilizing the work, the torque of the motor is the same as that of the original. (The motor torque is the same as the load torque, the load is constant and the motor torque is not changed)
Send your message to us
Frost frequency converter good delivery time and price
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords